  • Intel 82600 - page 1

    User Guide X B1 COM Express™ Module Document No. 4162 • Edition 5 2007-05 COM Ex p res s ...

  • Intel 82600 - page 2

    User Guide XB1 COM Express Module © E K F - 2 - e k f . c o m Contents A b o u t t h i s M a n u a l ........................................................... 4 E d i t i o n H i s t o r y ......................................................... 4 R e l a t e d D o c u m e n t s ..................................................... 5 N o m e n ...

  • Intel 82600 - page 3

    User Guide XB1 COM Express Module © E K F - 3 - e k f . c o m Connectors .......................................................... 3 1 P L D P r o g r a m m i n g H e a d e r I S P C O N ................................... 3 1 J - C O M ........................................................ 3 2 P r o c e s s o r D e b u g H e a d e r P I T P .. ...

  • Intel 82600 - page 4

    User Guide XB1 COM Express Module © E K F - 4 - e k f . c o m About this Manual This manual describes the technical aspects of the XB1 COM Express Module, required for installation and system integration. It is intended for the experienced user only. Edition History Ed. Contents/ Changes Author Date 1 User Manual XB1 COM Express Module, English, i ...

  • Intel 82600 - page 5

    User Guide XB1 COM Express Module © E K F - 5 - e k f . c o m Related Documents For ordering information refer to document XB1 COM Express Module Product Information, available at http://www.ekf.com/x/xb1/xb1_pie.pdf. Nomenclature Signal names used herein with an attached '#' designate active low lines. Trade Marks Some terms used herein ...

  • Intel 82600 - page 6

    User Guide XB1 COM Express Module © E K F - 6 - e k f . c o m XB1 COM Express Module Features Feature Summary Feature Summary X B1 Form Factor PICMG COM Express R1.0 (COM.0 ), Basic Module form factor (125x95mm 2 ), Pin-out Type 2 Processor Designed for Intel® Pentium® M Micro FC-BGA 479 processors (90nm Dothan), maximum junction temperature 100 ...

  • Intel 82600 - page 7

    User Guide XB1 COM Express Module Feature Summary X B1 © E K F - 7 - e k f . c o m Drivers < Intel graphics drivers < Intel networking drivers Power Requirements +12V ±0.5V, tbd A max. @2.0GHz (tbd A WinXP idle mode) Environmental Conditions < Operating temperature: 0°C ... +70°C (CPU dependent) < Storage temperature: -40°C ... +85 ...

  • Intel 82600 - page 8

    User Guide XB1 COM Express Module © E K F - 8 - e k f . c o m Short Description XB1 COM Express Module COM Express™ (also known as ETXexpress™) is an open PICMG ® standard for Computer-On- Modules, comprising of latest technologies such as PCI Express, Serial ATA, Gigabit Ethernet and SDVO. While designing the carrier board only once, users p ...

  • Intel 82600 - page 9

    User Guide XB1 COM Express Module © E K F - 9 - e k f . c o m Benefits of the X B1 COM Express Module < PICMG COM.0 Compliant Module Type 2 < Pentium® M 2GHz (FSB 533MHz) < PCI Express Chipset for Embedded Applications < 2 x 1GB DDR2 Memory (Dual Channel Mode Capable) < Dual-Screen Graphics Controller < Video I/F SDVO, PEG, LVDS ...

  • Intel 82600 - page 10

    User Guide XB1 COM Express Module © E K F - 1 0 - e k f . c o m Block Diagram XB1 COM Express Module SO -DIMM 2 00 Simplified Block Diagram COM Express Module X B1 Pe n t i u m ® M 2.0GHz 760 SO -DIMM 200 82 802 87 61 BIOS SIO G-ETH SDVO PEG PEG VGA LV D S / T V 3 x PCIe PCIe LPC AC '97 DDR2 533 512MB-2GB Dual Channel FSB 533MHz GMCH 82915 G ...

  • Intel 82600 - page 11

    User Guide XB1 COM Express Module © E K F - 1 1 - e k f . c o m Assembly Drawing XB1 COM Express Module GMCH J-GP GP LED PG J-RTC © EKF • B1 COM Expres s Module • ekf .com X X B1 To p © EKF ekf.com X B1 Bottom © EKF ekf.com CPU DDR2 SODIMM DDR2 SODIMM + BA T ICH P-SIO A1 C1 D1 B1 COM Express Module Connector J-COM A-B J-COM C-D P-ITP ISPCON ...

  • Intel 82600 - page 12

    User Guide XB1 COM Express Module © E K F - 1 2 - e k f . c o m Strapping Headers J-GP Jumper to reset BIOS CMOS RAM values J-RTC Jumper to reset RTC core of ICH6, not stuffed Connectors & Sockets ISPCON PLD programming connector, not stuffed J-COM A-B COM Express connector rows A and B (VGA, LVDS, TV, PCIe, SATA, Ethernet, USB, AC'97, SM ...

  • Intel 82600 - page 13

    User Guide XB1 COM Express Module © E K F - 1 3 - e k f . c o m Microprocessor The XB1 COM Express Module is designed for us e with Pentium® M and Celeron® M processors manufactured in 9 0nm technology (Dotha n). These include also the Ultra Low -Voltage (ULV) Celeron® M and the Low-Voltage (LV) Pentium® M processors as listed below. The proce ...

  • Intel 82600 - page 14

    User Guide XB1 COM Express Module © E K F - 1 4 - e k f . c o m Thermal Considerations In order to avoid malfunctioning of the XB1 COM Express M odule, take care of appropriate cooling of the processor and system, e.g. by a cooling fan suitable to the maximum power consumption of the CPU chip actually in use. Please note, that th e processors temp ...

  • Intel 82600 - page 15

    User Guide XB1 COM Express Module © E K F - 1 5 - e k f . c o m Main Memory The XB1 COM Express Module is equipped with tw o sockets for installing 200-pin SO-DIMM modules (module height = 1.25 inch). Support ed are unbuffered DDR2 SO-DIMMs (V CC =1.8V) without ECC featuring on-die termination (O DT), according the PC2-3200 or PC2-4200 specificati ...

  • Intel 82600 - page 16

    User Guide XB1 COM Express Module © E K F - 1 6 - e k f . c o m Serial ATA Interface (SATA) The XB1 COM Express Module provides four serial ATA (SATA) ports, each capable of transferring 150MB/s. Integrated within the ICH6, the SATA c ontroller features different modes to support also legacy operating systems. The SATA channels are available to th ...

  • Intel 82600 - page 17

    User Guide XB1 COM Express Module © E K F - 1 7 - e k f . c o m Graphics Subsystem The graphics subsystem is part of the versatile Intel i915GM Graphics/Memory Controller Hub (GMCH), and is also known as Intel Graphics Medi a Accelerator (GMA) 900. As an alternative, PCI Express based graphics is supported (req uires discre te PEG controller prese ...

  • Intel 82600 - page 18

    User Guide XB1 COM Express Module © E K F - 1 8 - e k f . c o m Real-Time Clock The XB1 COM Express Modu le has a time-of-day cl ock and 100-year calendar, integrated into the ICH6. A battery on the board keeps the clock current when the comp uter is turned off. The XB1 uses a Vanadium-Pentoxide-Lithium rechargeable battery, giving an autonomy of ...

  • Intel 82600 - page 19

    User Guide XB1 COM Express Module © E K F - 1 9 - e k f . c o m Watchdog/Reset The XB1 COM Express Module is prov ided with two supervisor circui ts to monitor the supply voltages 1.8V, 3.3V, 5V, and to gener ate a clean power-on reset signal. The healthy state of the XB1 COM Express Module immideately after a re set is signalled by the LED PG (P ...

  • Intel 82600 - page 20

    User Guide XB1 COM Express Module © E K F - 2 0 - e k f . c o m Installing and Replacing Components Before You Begin Warnings The procedures in this chapter assume familiar ity with the general terminology associated with industrial el ectronics and with safety practices and regulatory compliance required for using and modifying electronic equipme ...

  • Intel 82600 - page 21

    User Guide XB1 COM Express Module © E K F - 2 1 - e k f . c o m Installing the Board Warning This procedure should be done only by qualified te chnical personnel. Disconnect the system from its power source before doing the procedures desc ribed here. Failure to disconnect power, or telecommunication links before you open the system or perform any ...

  • Intel 82600 - page 22

    User Guide XB1 COM Express Module © E K F - 2 2 - e k f . c o m Removing the Board Warning This procedure should be done only by qualified te chnical personnel. Disconnect the system from its power source before doing the procedures desc ribed here. Failure to disconnect power, or telecommunication links before you open the system or perform any p ...

  • Intel 82600 - page 23

    User Guide XB1 COM Express Module © E K F - 2 3 - e k f . c o m EMC Recommendations In order to comply with the CE regulations for EM C, it is mandatory to observe the following rules: C The chassis or rack including other boards in use must comply entirely with CE C Close all board slots not in use with a blind front panel C Front panels must be ...

  • Intel 82600 - page 24

    User Guide XB1 COM Express Module © E K F - 2 4 - e k f . c o m Installing or Replacing the Memory Modules Note: If you decide to replace the memory, observe the precautions in 'Before You Begin' By default, the XB1 COM Expres s Mod ule comes fully equipped and tested with two DDR2 SDRAM memory modules. So normally there should be no nee ...

  • Intel 82600 - page 25

    User Guide XB1 COM Express Module © E K F - 2 5 - e k f . c o m Technical Reference Local PCI Devices The following table shows the on-board PCI devices and their location within the PCI configura tion space. These devices reside mainly within the i915GM chipset. Bus Number Device Number Function Number Vendor ID Device ID Description 0 0 0 0x8086 ...

  • Intel 82600 - page 26

    User Guide XB1 COM Express Module © E K F - 2 6 - e k f . c o m Local SMB Devices The XB1 COM Express Module contains a few devices that are attached to the System Management Bus (SMBus). These are the clock generation chip, the SPD EEPROMs on the SO-DIMM memory modules, a general purpose serial EEPROM and a supply voltage and CPU temperature cont ...

  • Intel 82600 - page 27

    User Guide XB1 COM Express Module © E K F - 2 7 - e k f . c o m GPIO Usage GPIO Usage ICH6 XB1 COM Express Module GPIO Usage ICH6 GPIO Type Tol. Function Description GPI 0 I 5V EXCD1_CPPE# PCI ExpressCard PCI Express capable card 1 request GPI 1 I 5V EXCD0_CPPE# PCI ExpressCard PCI Express capable card 0 request GPI 2 I 5V PG_VR33 Power Good signa ...

  • Intel 82600 - page 28

    User Guide XB1 COM Express Module XB1 COM Express Module GPIO Usage ICH6 GPIO Type Tol. Function Description © E K F - 2 8 - e k f . c o m GPI 30 I 3.3V BOARD_CFG2 Board configuration options line 2 GPI 31 I 3.3V BOARD_CFG3 Board configuration options line 3 GPIO 32 O 3.3V not used - open (configured as output by BIOS) GPIO 33 O 3.3V NC1_OFF# Enab ...

  • Intel 82600 - page 29

    User Guide XB1 COM Express Module © E K F - 2 9 - e k f . c o m GPIO Usage SIO XB1 COM Express Module GPIO Usage SIO GPIO Type Tol. Function Description GPIO 10 I/O 5V/16mA 1) MSDAT PS/2 mouse data or custom GPIO GPIO 11 I/O 5V/16mA 1) MSCLK PS/2 mouse clock or custom GPIO GPIO 12 O LPC_DRQSIO# LPC Port DMA request from SIO GPIO 13 I/O 5V/8mA 1) n ...

  • Intel 82600 - page 30

    User Guide XB1 COM Express Module © E K F - 3 0 - e k f . c o m Configuration Jumpers Reset Jumper BIOS CMOS RAM Values (J-GP) The jumper J-GP is used to rese t the contents of the battery backe d CMOS RAM to their default state. The BIOS uses the CMOS to store configuration va lues, e.g. the order of boot devices. Using this jumper is appropriate ...

  • Intel 82600 - page 31

    User Guide XB1 COM Express Module © E K F - 3 1 - e k f . c o m Connectors Caution Some of the internal connectors provide operating voltage (3.3V and 5V) to devices inside the system chassis, such as internal peripherals. Not all of these connectors are overcurrent protected. Do not use these int ernal connectors for poweri ng devices ex ternal t ...

  • Intel 82600 - page 32

    User Guide XB1 COM Express Module © E K F - 3 2 - e k f . c o m J-COM J-COM is the pair of connectors which serves as interface between the XB1 COM Express Module and the carrier board. The assembly is composed of two double-row, high speed, 0.5mm pitch plugs. Each row has 110 leads, i.e. J-COM provides 440 cont act positions in total. The COM.0 s ...

  • Intel 82600 - page 33

    User Guide XB1 COM Express Module AB # C D © E K F - 3 3 - e k f . c o m GND GND 31 GND GND AC_BITCLK SPKR 3 2 PCI_AD14 PCI_PAR AC_SDOUT I 2C_CK 33 PCI_CBE1# PCI_SERR# BIOS_DISABLE # I2C_DAT 34 PCI_PERR# PCI_STOP# THRMTRIP# THRM# 35 PCI_LOCK# PCI_TRDY# USB_6N USB_7N 36 PCI_DEVSEL# PCI_FRAME# USB_6P USB_7P 37 PCI_IRDY# PCI_ AD16 USB_OC67# USB_OC45# ...

  • Intel 82600 - page 34

    User Guide XB1 COM Express Module AB # C D © E K F - 3 4 - e k f . c o m GND GND 60 GND GND PCIE_TX2+ PCIE_RX2+ 61 PEG_RX3+ SDVOB_ CLK+ PEG_TX3+ PCIE_TX2- PCIE_RX2- 62 PEG_RX3- SDVOB_CLK- PEG_TX 3- GPI1 GPO3 63 RSVD RSVD PCIE_TX1+ PCIE_RX1+ 64 RSVD RSVD PCIE_TX1- PCIE_RX1- 65 PEG_RX4+ SDVOC_RED+ PEG_ TX4+ GND PE_WAKE# (WAKE0#) 66 PEG_RX4- SDVOC_RE ...

  • Intel 82600 - page 35

    User Guide XB1 COM Express Module AB # C D © E K F - 3 5 - e k f . c o m GND GND 90 GND GND RSVD VGA_GREEN 91 PEG_ RX12+ PEG_TX12+ RSVD VGA_BLUE 92 PEG_RX12- PEG_TX12- GPO0 VGA_HSYNC 93 GND GND RSVD VGA_VSYNC 94 PEG_R X13+ PEG_TX13+ RSVD VGA_DDCCL (VGA_I2C_ CK) 95 PEG_RX13- PEG_TX13- GND VGA_ DDCDAT (VGA_I2C _DAT) 96 GND GND +12V TV_DAC _A 97 RSVD ...

  • Intel 82600 - page 36

    User Guide XB1 COM Express Module © E K F - 3 6 - e k f . c o m Processor Debug Header PITP This FFC style connector (Molex 52435-2872) can be us ed to attach an emulator probe to the board. This is a valuable tool when debugging hardware or tracing software. The connector PITP is situated at the bottom side of the board. PITP 1T D I 2T M S 3T R S ...

  • Intel 82600 - page 37

    User Guide XB1 COM Express Module © E K F - 3 7 - e k f . c o m P-SIO The connector P-SIO is normally not stuffed. The ma ture PS/2 and UART ports have been overcome by USB in most applications. For low level debugging howev er, these interfaces can be very useful (e.g. the BIOS can communicate across the serial I/O). Please contact EKF before o r ...

  • Intel 82600 - page 38

    User Guide XB1 COM Express Module © E K F - 3 8 - e k f . c o m Board Dimensions D1 A1 T op View ( seen through board) connectors COM Express Basic Module © EKF ekf. com 4.00 4.00 16.50 74.20 80.00 121.00 125.00 6.00 18.00 91.00 95.00 ...

  • Intel 82600 - page 39

    User Guide XB1 COM Express Module © E K F - 3 9 - e k f . c o m Top View, Bottom View XB1 Top View XB1 Bottom View ...

  • Intel 82600 - page 40

    User Guide XB1 COM Express Module Literature Theme Document Title Origin COM Express PICMG ® COM.0 COM Express™ Module Base Specification Revision 1.0 2005-07 www.picmg.org Ethernet IEEE Std 802.3, 2000 Edition standards.ieee.org PCI Express PCI Express Base Specification 1.1 www.pcisig.com Serial ATA Serial ATA Revision 2.5 www.serialata.org US ...

Fabbricante Intel Categoria Switch

I documenti che otteniamo dal fabbricante del dispositivoIntel 82600 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Intel
- manuali per l’uso 82600
- schede prodotto Intel
- opuscoli
- o etichette energetiche Intel 82600
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Intel 82600.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Intel 82600, manuali di manutenzione, brevi manuali o manuali utente Intel 82600. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Intel 82600.

Manuali per l’uso simili

Manuale completo del dispositivo Intel 82600, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Intel 82600 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Intel 82600.

Il manuale per l’uso completo Intel, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Intel 82600 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Intel 82600, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Intel 82600 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Intel 82600 - che ci dovrebbe aiutare nei primi passi durante l'uso Intel 82600
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Intel 82600
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Intel 82600 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Intel 82600?

Utilizza il modulo sottostante

Se non hai risolto il problema con Intel 82600 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Intel 82600 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)