    P AINT SPRA YER HVLP-ELECTRIC Model 97750 SET UP AND OPERA TING INSTRUCTIONS Diagrams within this manual may not be drawn proportionally . Due to continuing improvements, actual product may differ slightly from the product described herein. Distributed exclusively by Harbor Freight T ools ® . 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our ...

  • Chicago Electric 97750 - page 2

    Page 2 SKU 97750 For technical questions, please call 1-800-444-3353. SA VE THIS MANUAL Keep this manual for the safety warn- ings and precautions, assembly , operat- ing, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if produc ...

  • Chicago Electric 97750 - page 3

    Page 3 SKU 97750 For technical questions, please call 1-800-444-3353. Unmodied plugs and matching out - lets will reduce risk of electric shock. A void body contact with grounded b. surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is grounded. Do not expose power tools to rain ...

  • Chicago Electric 97750 - page 4

    Page 4 SKU 97750 For technical questions, please call 1-800-444-3353. Disconnect the Power Cord (34) c. from the power source before mak- ing any adjustments, changing ac- cessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally . Store idle power tools out of the d. reach of childre ...

  • Chicago Electric 97750 - page 5

    Page 5 SKU 97750 For technical questions, please call 1-800-444-3353. Never release the Lower Cover (24) 7. while the Cup (27) is pressurized. Industrial applications must follow 8. OSHA requirements. Make sure air intake guard is in 9. place before use. Never point a Spray Gun at people 10. or animals. Serious injury could oc - cur . Spraying haza ...

  • Chicago Electric 97750 - page 6

    Page 6 SKU 97750 For technical questions, please call 1-800-444-3353. GROUNDING TO PREVENT ELECTRIC SHOCK AND DEA TH FROM INCORRECT GROUNDING WIRE CONNECTION: Check with a qualied electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the Power Cord Plug (34) provided with the tool. Never remove the groundin ...

  • Chicago Electric 97750 - page 7

    Page 7 SKU 97750 For technical questions, please call 1-800-444-3353. Double insulated tools may be used 2. in either of the 120 volt outlets shown in the preceding illustration. (See Outlets for 2-Prong Plug.) Extension Cords Grounded 1. tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension ...

  • Chicago Electric 97750 - page 8

    Page 8 SKU 97750 For technical questions, please call 1-800-444-3353. SPECIFICA TIONS Electrical Requirements 120 V~ / 60 Hz / 450 W atts 5.5 Amps (Start Up) 3.3 Amps (Load & No Load) Motor Speed: 30,000 RPM Power Plug: 2-Prong Power Switch: ON/OFF Rocker Spray Cup Capacity 1 Quart Output Pressure 1.45 to 4.35 PSI Activation Method T rigger Sty ...

  • Chicago Electric 97750 - page 9

    Page 9 SKU 97750 For technical questions, please call 1-800-444-3353. W ork Piece and Work Area Set Up Designate a work area that is clean 1. and well-lit. The work area must not allow access by children or pets to prevent injury and distraction. Route the Power Cord (34) along a 2. safe route to reach the work area without creating a tripping haza ...

  • Chicago Electric 97750 - page 10

    Page 10 SKU 97750 For technical questions, please call 1-800-444-3353. FIGURE C FLA T/OPEN ROUND/CLOSED 9. After setting up a piece of scrap mate- rial, squeeze the T rigger (6) in short bursts while turning the Fluid Control Screw (19) counterclockwise and observe the pattern for consistency . T oo much air may cause the spray to come out too n ...

  • Chicago Electric 97750 - page 11

    Page 1 1 SKU 97750 For technical questions, please call 1-800-444-3353. MAINTENANCE AND SER VICING Procedures not specically explained in this manual must be performed only by a qualied technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn the Power Switch (33) of the Paint Sprayer to its “OFF” position and unplug the ...

  • Chicago Electric 97750 - page 12

    Page 12 SKU 97750 For technical questions, please call 1-800-444-3353. may still remain in the Spray Gun. Point the Gun into the spent solvent container and squeeze the T rigger (6) again to make sure no air re- mains. Remove the T op Cover (22) and • soak it in solvent/water until it is clean. Use an old toothbrush and toothpicks to remove any r ...

  • Chicago Electric 97750 - page 13

    Page 13 SKU 97750 For technical questions, please call 1-800-444-3353. TROUBLESHOOTING - GENERAL IMPORT ANT : Improper cleaning is a common reason for the unit not to work properly . Most problems can be avoided or remedied with prompt, thorough cleaning. Problem Possible Causes Possible Solutions Sputtering spray . Low uid level. 1. Cup tipped ...

  • Chicago Electric 97750 - page 14

    Page 14 SKU 97750 For technical questions, please call 1-800-444-3353. TROUBLESHOOTING - SPRA Y P A TTERN IMPORT ANT : Improper cleaning is a common reason for the unit not to work properly . Most problems can be avoided or remedied with prompt, thorough cleaning. The illustrations below resemble symptoms of spray pattern problems. Refer to the ill ...

  • Chicago Electric 97750 - page 15

    Page 15 SKU 97750 For technical questions, please call 1-800-444-3353. P ARTS LIST & ASSEMBL Y DIAGRAM 13 34 33 Shoulder Strap (35) not shown. Part # Description Part # Description 1 Seal Nut 19 Fluid Control Screw 2 Gasket 20 O-Ring 3 Fluid Nozzle 21 Gasket 4 Air Nozzle 22 T op Cover 5 Air Cap Screw 23 Cup Gasket 6 T rigger 24 Lower Cover 7 Bo ...

  • Chicago Electric 97750 - page 16

    Page 16 SKU 97750 For technical questions, please call 1-800-444-3353. LIMITED 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every ef fort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this prod- uct is free from defects in materials and workmanship for the period of 90 days ...

Fabbricante Chicago Electric Categoria Paint Sprayer

I documenti che otteniamo dal fabbricante del dispositivoChicago Electric 97750 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Chicago Electric
- manuali per l’uso 97750
- schede prodotto Chicago Electric
- opuscoli
- o etichette energetiche Chicago Electric 97750
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Chicago Electric 97750.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Chicago Electric 97750, manuali di manutenzione, brevi manuali o manuali utente Chicago Electric 97750. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Chicago Electric 97750.

Manuale completo del dispositivo Chicago Electric 97750, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Chicago Electric 97750 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Chicago Electric 97750.

Il manuale per l’uso completo Chicago Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Chicago Electric 97750 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Chicago Electric 97750, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Chicago Electric 97750 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Chicago Electric 97750 - che ci dovrebbe aiutare nei primi passi durante l'uso Chicago Electric 97750
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Chicago Electric 97750
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Chicago Electric 97750 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Chicago Electric 97750?

Utilizza il modulo sottostante

Se non hai risolto il problema con Chicago Electric 97750 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Chicago Electric 97750 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)