    GENERA T OR 2.4 HP - 1000 W A T T Model 93881 ASSEMBL Y AND OPERA TING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo , CA 93011 Visit our Web site at: http://www .harborfreight.com Copyright © 2006 b y Harbor F reight T ools ® . All r ights reserved. No por tion of this manual or any artwork contained herein may be reproduced in any shape or fo ...

  • Chicago Electric 93881 - page 2

    PRODUCT SPECIFICA TIONS SA VE THIS MANU AL Y ou will need this man ual for the safety w ar nings and precautions , assembly , operating, inspection, maintenance and cleaning procedures , par ts list and assemb ly diagram. K eep y our inv oice with this manual. Write the in voice n umber on the inside of the front cov e r . K eep this manual and in ...

  • Chicago Electric 93881 - page 3

    PERSONAL SAFETY 1. Stay alert. Watc h what you are doing, and use common sense when operating a power tool. Do not use a power tool while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating po wer tools may result in ser ious personal injur y . 2. Dress properl y . Do not wear loose clothing or je ...

  • Chicago Electric 93881 - page 4

    SKU 93881 For tec hnical questions, please call 1-800-444-3353 P A G E 4 6. Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one tool may become hazardous when used on another tool. SER VICE 1. T ool service m ust be perf ormed onl y b y qualified repair personnel. Service or mainten ...

  • Chicago Electric 93881 - page 5

    SKU 93881 For tec hnical questions, please call 1-800-444-3353 P A G E 5 8. This Generator is designed f or outdoor use only . Do not operate the Gener ator in a closed area or in a poorly ventilated area. When running, the Engine of this Generator produces carbon monoxide, a colorless, odorless, toxic fume that, when inhaled, can cause serious per ...

  • Chicago Electric 93881 - page 6

    the Engine and Generator to completely cool. Then, remove the spark plug from the Engine. 2. Do not alter or adjust any part of the Generator or Engine that is assemb l ed and supplied b y the man ufacturer . 3. Alwa ys follo w and complete scheduled Generator and Engine maintenance. CHEMICAL PRECA UTIONS 1. A void contact with hot fuel, oil, e xha ...

  • Chicago Electric 93881 - page 7

    MISC. PRECA UTIONS 1. W ARNING! P eople with pacemakers should consult their ph ysician(s) before using this product. Oper ation of electrical equipment in close proximity to a hear t pacemak er could cause interference to or f ailure of the pacemaker . 2. W ARNING! The w ar nings and precautions discussed in this manual cannot cov er all possible ...

  • Chicago Electric 93881 - page 8

    UNP ACKING When unpac king, check to make sure all the part s sho wn on the P arts Lists on pag es 17, 18, and 19 are included. If any par ts are missing or brok en, please call Harbor F reight T ools at the number sho wn on the cov er of this manual as soon as possib l e . ASSEMBL Y INSTR UCTIONS 1. CA UT IO N! Always mak e sure the P ower Switch ...

  • Chicago Electric 93881 - page 9

    SKU 93881 For tec hnical questions, please call 1-800-444-3353 P A G E 9 4. If necessary , continue adding engine oil, while rechec king the Oil Dipstick, until the oil le vel reaches the “MAXIMUM” indicator on the Oil Dipstick . Do not e xceed the “MAXIMUM” indicator mark on the Oil Dipstic k. (See Figure A.) 5. When finished adding engine ...

  • Chicago Electric 93881 - page 10

    SKU 93881 For tec hnical questions, please call 1-800-444-3353 P A G E 1 0 supply all electr ical loads the unitwill po w er . If po wer ing e xceeds the Gener ator’ s capacity , it may be necessary to group one or more of the tools/equipment f or connection to a separate Generator . General Location: 1. It is recommended to locate the Generator ...

  • Chicago Electric 93881 - page 11

    SKU 93881 For technical questions, please call 1-800-444-3353 P A G E 1 1 PRODUCT FEA TURES FUEL CAP (5B) AC CIRCUIT BREAKERS (12) POWER ON LIGHT (13) 120 V OL T A C OUTLET (4) ENGINE POWER SWITCH (14) OIL DIPSTICK CO VER (12B) GROUNDING NUT (7) ENGINE PULL- ST ART CORD DC CIRCUIT BREAKER (10) 12V DC OUTLET (8) FIGURE E 1. Engine P ower Switch (14) ...

  • Chicago Electric 93881 - page 12

    SKU 93881 For tec hnical questions, please call 1-800-444-3353 P A G E 1 2 the Circuit Break er and restar t the Engine. (See Figure E.) 7. Gr ounding Nut (7): Use this f eature to attach a ground wire to an external ear th ground. (See Figures D and E.) 8. Oil Dipstick C o ver (12B): Remov e this Co ver to fill and check the le vel of Engine oil. ...

  • Chicago Electric 93881 - page 13

    SKU 93881 For tec hnical questions, please call 1-800-444-3353 P A G E 1 3 T o Star t The Engine/Generator: 1. T ur n the Engine Fuel V al v e Le ver to its “OPEN” position. Then, turn the Engine Chok e Le ver to its “CHOKE” position. NO TE: No chok e is required if the Engine is warm. Mak e sure the Engine Choke Lev er is in the “RUN” ...

  • Chicago Electric 93881 - page 14

    SKU 93881 For tec hnical questions, please call 1-800-444-3353 P A G E 1 4 T o Connect Electrical Loads: 1. Star t the Engine , and allow the Engine and Gener ator to run and war m up f or fiv e minutes after star ting with no electrical load. 2. W ARNING! Connect 120V AC appliances, tools , and equipment onl y to the two 120V A C Outlets. Connect ...

  • Chicago Electric 93881 - page 15

    SKU 93881 For tec hnical questions, please call 1-800-444-3353 P A G E 1 5 9. Once the Engine is running, simply connect the 120 volt appliances, tools, and equipment into the 120V AC Outlets (4) and/or connect a 12 v olt appliance , tool, or equipment into the 12V DC Outlet (8). (See Figure E.) 10. IMPOR T ANT : If Engine speed or v oltage fluctua ...

  • Chicago Electric 93881 - page 16

    SKU 93881 For technical questions, please call 1-800-444-3353 P A G E 1 6 TROUBLESHOO TING PLEASE READ THE FOLLO WING CAREFULL Y THE MANUF ACTURER AND/OR DISTRIB UTOR HAS PRO VIDED THE P A R TS LIST AND ASSEMBL Y DIAGRAM IN THIS MANU AL AS A REFERENCE T OOL ONL Y . NEITHER THE MANUF ACTURER OR DISTRIBUT OR MAKES ANY REPRESENT A TION OR W ARRANTY OF ...

  • Chicago Electric 93881 - page 17

    P ARTS LIST & ASSEMBL Y DIA GRAM - CONTR OL P ANEL SKU 93881 For technical questions, please call 1-800-444-3353 P A G E 1 7 NOTE: Some parts are listed and sho wn f or illustration purposes only , and are not av ailable individually as replacement par t s. P a rt # D e sc rip t i on Q ty. P a rt # D e sc r ipt i on Q ty . 1 Wiri n g H arness A ...

  • Chicago Electric 93881 - page 18

    P ARTS LIST & ASSEMBL Y DIA GRAM - GENERA T OR ASSY . NOTE: Some par ts are listed and shown f or illustration purposes only , and are not a v ailable individually as replacement par t s. SKU 93881 For technical questions, please call 1-800-444-3353 P A G E 1 8 P a rt # D e sc rip t i on Q ty. P a rt # D e sc rip t i on Q ty. 1A Flange Bol t ( ...

  • Chicago Electric 93881 - page 19

    NOTE: Some par ts are listed and shown f or illustration purposes only , and are not a v ailable individually as replacement par t s. P a rt # D e scr i p tio n Q ty. P a rt # D e sc ri pt i on Q t y . 1B Lef t Hou si ng 1 23B S cr ew ( M 4x10 ) 1 2B Screw (ST4 .2x13 ) 16 24B Nut ( M6) 4 3B Fue l T ank 1 25B Ai r S hr oud (1) 1 4B Fue l F i l t er ...

  • Chicago Electric 93881 - page 20

    SKU 93881 For tec hnical questions, please call 1-800-444-3353 P A G E 2 0 ITEM 9 3 88 1 1000 W 1000 W A TT TT GENERA GENERA T O O R Engine: Mitsubishi ® Model MH 8 2, 2.4 HP , 4-str oke, OHV , 3600 RPM, Recoil Start, CDI; Generator Output: 120 V A C, 60 Hz; 950 W att Rated; 1000 W att Maxim um; Fuel Capacity: 1.1 8 Gallons, Gasoline Fuel, Appro x ...

Fabbricante Chicago Electric Categoria Portable Generator

I documenti che otteniamo dal fabbricante del dispositivoChicago Electric 93881 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Chicago Electric
- manuali per l’uso 93881
- schede prodotto Chicago Electric
- opuscoli
- o etichette energetiche Chicago Electric 93881
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Chicago Electric 93881.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Chicago Electric 93881, manuali di manutenzione, brevi manuali o manuali utente Chicago Electric 93881. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Chicago Electric 93881.

Manuali per l’uso simili

Manuale completo del dispositivo Chicago Electric 93881, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Chicago Electric 93881 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Chicago Electric 93881.

Il manuale per l’uso completo Chicago Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Chicago Electric 93881 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Chicago Electric 93881, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Chicago Electric 93881 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Chicago Electric 93881 - che ci dovrebbe aiutare nei primi passi durante l'uso Chicago Electric 93881
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Chicago Electric 93881
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Chicago Electric 93881 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Chicago Electric 93881?

Utilizza il modulo sottostante

Se non hai risolto il problema con Chicago Electric 93881 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Chicago Electric 93881 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)