Manuale per l’uso Extron electronic 42-122-xx

28 pagine 11.29 mb
Scarica

Vai alla pagina of 28

Summary
  • Extron electronic 42-122-xx - page 1

    A VT rac ® International/Universal Models Floor -mount Raceway with Modular AAP Connectivity for A/V , Data, and Power Installation Guide 68-1562-01 Rev . A 09 08 ...

  • Extron electronic 42-122-xx - page 2

    This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’ s enclosure that may present a risk of electric shock. Caution Read Instructions • ...

  • Extron electronic 42-122-xx - page 3

    Intr oduction A VT rac • Introduction 1 This manual describes the A VT rac ® components and provides instructions for installation. Low-profile Raceway System A VT rac is a low-profile raceway system designed to safely and discretely run power , data, and A/V cables from a wall to a table, podium, or other furniture. The raceway system mounts ...

  • Extron electronic 42-122-xx - page 4

    Kit Contents A VT rac • Kit Contents 2 Box 1 The A VT rac Kit is shipped in two boxes. Box 1 • contains the track and ramp components. Box 2 • contains the connectivity box, the conduit and accessory components. Check the contents of each box to ensure all items are present. Plastic T emplate (1) Side Ramp (2) Rubber Strip (1) (only wit ...

  • Extron electronic 42-122-xx - page 5

    Kit Contents A VT rac • Kit Contents 3 Box 2 Check the contents of each box to ensure all items are present. Checklist for contents of box 2 Connectivity box (1) with 6/32" nut (1) to secure AC power module  9.35" (23.7 cm) quarter-cir cle end ramps (2)  Cover AAP plate for AC power module (1)  Double-sided adhesive tape (1 rol ...

  • Extron electronic 42-122-xx - page 6

    Befor e Getting Started A VT rac • Before Getting Started 4 A VT rac can be installed before new carpeting is fitted or retr ofitted under pre-existing carpet. It can also be installed in new construction before the wall and carpeting is in place. Retr ofitting the track in a space with existing carpeting and furniture r equires some extra pr ...

  • Extron electronic 42-122-xx - page 7

    A VT rac • Before Getting Started 5 Conference Room AV Tr ac Cable Cub by MediaLink Controller Room Considerations Determine the A/V requir ements for the room. Extr on provides a complete range of AAPs that can be purchased separately to provide fully customizable central connectivity . Select the best configuration for existing furniture, equi ...

  • Extron electronic 42-122-xx - page 8

    Befor e Getting Started, cont’d A VT rac • Before Getting Started 6 Almost everything you need to install your A VT rac system has been included. Y ou will need some basic tools and materials depending on the facility and requir ements. Y ou can visit www .extron.com for a full range of cables and components for populating the connectivity box. ...

  • Extron electronic 42-122-xx - page 9

    Installation A VT rac • Installation 7 Step 1: Floor By this point you must have decided exactly where the A VT rac will be installed, checked the contents of the kit, and gathered the tools that you will need. Extron r ecommends consulting a carpeting expert before r emoving the carpet. 1-1 Determine whether the installation will be in new const ...

  • Extron electronic 42-122-xx - page 10

    Installation A VT rac • Installation 8 Step 2: W all Cut cable access hole in wall 2-2 Using a drill, box cutters and/or a saw , cut a 4" W x 1½" H (10.2 cm x 3.8 cm) hole at the base of the wall. If there is a metal base stud, use a hand saw or tin snips to cut it at both edges of the hole and bend it back into the hole so that the st ...

  • Extron electronic 42-122-xx - page 11

    Installation A VT rac • Installation 9 Step 3: T rack Measure and cut track 10.00" (25.4 cm) Connectivity (AAP) Box Rubber Strip Aluminum Cover T rac k 7'-2 " (2.184 m) 9.36" (23.77 cm) 8'-0 " (2.438 m) End Ramp Side Ramp Cut aluminum base track 3-1 Measure and cut the track pieces to the desir ed length. N If the tr ...

  • Extron electronic 42-122-xx - page 12

    Installation A VT rac • Installation 10 Step 3: T rack, cont’d Pre-drill holes to secur e connectivity box End Plate End Plate Co ve r Mounting Holes The end of the Connectivity Box with three mounting holes fa ces back to wa rds the track. 3-3 Remove the cover panel and end plates from the connectivity box. Examine the bottom of the connectivi ...

  • Extron electronic 42-122-xx - page 13

    A VT rac • Installation 11 Drill a 5/32 ” x 1 1/2” deep hole into concrete. Supplied Masonry Screws Drill into concrete and scr ew down track Screw side ramps to floor 3-6 W ith the provided masonry screws, secur e the track and ramps to the floor . 3-5 Using the provided 5/32" masonry bit, drill 1 1/2" (3.8 cm) deep pilot holes i ...

  • Extron electronic 42-122-xx - page 14

    Installation A VT rac • Installation 12 Step 4: Connectivity Box By this point, the base track, side ramps and end ramps must be securely fastened to the floor . T o attach the connectivity box to the base track, follow these instructions: Secure connectivity box to the floor Masonry Screws The end of the connectivity box with three mounting ho ...

  • Extron electronic 42-122-xx - page 15

    Installation A VT rac • Installation 13 Step 5: Power Module (F) (D) (E) Receptacles for the AC power modules are available in Australian (F), universal (J), central European (D), and Fr ench (E) models. The Australian and Universal models are pr ovided with 24' of metal conduit, without wires (CO models). The Central Eur opean, French, and ...

  • Extron electronic 42-122-xx - page 16

    Installation A VT rac • Installation 14 Step 5: Power Module cont’d 5-2 The AC power module must be positioned under the triple AAP socket that is closest to the track. Seat the power module on the stud in the connectivity box. Slide the power module side tabs into the slots on the side of the connectivity box. Secure the module to the stud on ...

  • Extron electronic 42-122-xx - page 17

    Installation A VT rac • Installation 15 Step 6: AAPs At this point, the track, ramps and connectivitly box must all be securely in place, and the AC power module must be attached to the connectivity box and connected to an AC junction box. T o attach the Ar chitectural Adapter Plates (AAPs), follow these instructions: 6-1 Select up to seven AAPs ...

  • Extron electronic 42-122-xx - page 18

    Installation A VT rac • Installation 16 Step 7: Finishing Up At this point, the track and connectivity box must be secured to the floor , the electrical power must be connected, and the AAP sockets must be populated. T o complete the installation of the A VT rac, follow these instructions: 7-1 Lay the cables and power cords flat against the bas ...

  • Extron electronic 42-122-xx - page 19

    A VT rac • Installation 17 7-4 Glue or tape the carpet to the floor and side ramps. Refit carpet 7-5 Using the provided template, trim the wall baseboard to fit snugly ar ound the track. Attach the baseboard to the wall. Use template to cut base board 7-6 For 42-122- xx models, attach the provided rubber strip to the cover track raceway using ...

  • Extron electronic 42-122-xx - page 20

    Installation A VT rac • Installation 18 Step 7: Finishing up cont’d The installed A VT rac safely and discretely runs power , data, and A/V cables from a wall to a table, podium, or other furniture. A VT rac installed ...

  • Extron electronic 42-122-xx - page 21

    Refer ence Material A VT rac • Reference Material 19 Specifications General Power (pass-through) ................... 250 V AC, 50/60 Hz, 10 A (max.) Mounting options T rack system (track and ramps) Mountable on base flooring, beneath the finished carpet Connectivity box ............... Mountable through the metal track, onto base flooring Opti ...

  • Extron electronic 42-122-xx - page 22

    Refer ence Material, A VT rac • Reference Material 20 cont’d Connectivity box TOP VIEW End Ramp Side Ramp Aluminum T rack Connectivity (AAP) Box 9.36” (23.77 cm) 18.72” (47.55 cm) 10.00” (25.4 cm) 8’-0” (2.438 m) 2.68” (6.8 cm) AVTrac 480R 3.70" (9.40 cm) .67" (1.70 cm) 4.5° 7.50" (19.05 cm) 7.50" (19.05 cm) .95 ...

  • Extron electronic 42-122-xx - page 23

    A VT rac • Reference Material 21 SIDE VIEW TO P VIEW END VIEW 4.91" (12.47 cm) 3.55" (9.02 cm) 10.00" (25.4 cm) 10.00" (25.4 cm) 4.91" (12.47cm) 3.55" (9.02 cm) 2.98" (7.57 cm) .67" (1.70 cm) Connectivity box ...

  • Extron electronic 42-122-xx - page 24

    Refer ence Material, A VT rac • Reference Material 22 cont’d Earth/Ground Live/Hot Phase/Active Neutral The Extron Universal AC Outlet allows a number of different AC plugs to be used in the A VT rac ™ , HSA, and Cable Cubby ™ devices. Before using the device, refer to the table on this card to see if your plug type is compatible with the U ...

  • Extron electronic 42-122-xx - page 25

    A VT rac • Reference Material 23 Please consult the Extron W eb site (www .Extron.com) or catalog for a complete description of each item. T rack Accessories Accessory Part Number A VT rac 4 ' T rack Extension Kit for Carpet Inlay 70-645-04 A VT rac 4 ' T rack Extension Kit for Rubber Inlay 70-646-04 A VT rac Rough-In Adapter 70-781-01 ...

  • Extron electronic 42-122-xx - page 26

    Refer ence Material, A VT rac • Reference Material 24 cont’d ...

  • Extron electronic 42-122-xx - page 27

    Extr on’ s W arranty Extron Electr onics warrants this product against defects in materials and workmanship for a period of three years fr om the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extr on Electronics will, at its option, repair or r eplace said pr ...

  • Extron electronic 42-122-xx - page 28

    A VT rac • Quick Installation Checklist Ex tron US A - We st Headquar te rs + 800 .6 33 .9 87 6 Insid e U S A / C anad a On ly +1 .7 14 .4 91 .1 50 0 +1 .7 14 .4 91 .1 51 7 FA X Ex tron US A - Eas t + 800 .6 33 .9 87 6 Insid e U S A / C anad a On ly +1 .9 19 .8 63 .1 79 4 +1 .9 19 .8 63 .1 79 7 FA X Ex tron EM EA + 800 .3 98 7. 66 73 Insid e E ur ...

Fabbricante Extron electronic Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoExtron electronic 42-122-xx possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Extron electronic
- manuali per l’uso 42-122-xx
- schede prodotto Extron electronic
- opuscoli
- o etichette energetiche Extron electronic 42-122-xx
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Extron electronic 42-122-xx.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Extron electronic 42-122-xx, manuali di manutenzione, brevi manuali o manuali utente Extron electronic 42-122-xx. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Extron electronic 42-122-xx.

Manuale completo del dispositivo Extron electronic 42-122-xx, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Extron electronic 42-122-xx dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Extron electronic 42-122-xx.

Il manuale per l’uso completo Extron electronic, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Extron electronic 42-122-xx - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Extron electronic 42-122-xx, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Extron electronic 42-122-xx che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Extron electronic 42-122-xx - che ci dovrebbe aiutare nei primi passi durante l'uso Extron electronic 42-122-xx
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Extron electronic 42-122-xx
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Extron electronic 42-122-xx in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Extron electronic 42-122-xx?

Utilizza il modulo sottostante

Se non hai risolto il problema con Extron electronic 42-122-xx con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Extron electronic 42-122-xx è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)