  • White Rodgers 1F95-1291 - page 1

    Model Programming Choices 1F95-1291 7 Day 5/1/1 Day Non-Programmab le www .white-rodgers .com Big Blue Humidity Univ er sal T her mostat with Humidity/Dehumidity Control and Automa tic Heat/Cool Changeo v er Option P ART NO . 37-6914D Replaces 37-6914C 0905 Single Stage, Multi-Stage, Heat Pump Installation and Operating Instructions APPLICA TIONS 1 ...

  • White Rodgers 1F95-1291 - page 2

    2 Remove Old Thermostat Bef ore removing wires from old thermostat, mar k wires f or terminal identifi cation so the proper connections will be made to the new thermostat. Installing New Thermostat 1. Pull the thermostat body off the ther mostat base. Forcing or pr ying on the thermostat will cause damage to the unit. 2. Place base ov er hole in w ...

  • White Rodgers 1F95-1291 - page 3

    3 WIRING DIA GRAMS Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single T ransformer Single Stage 1 (SS1) Multi Stage 2 (MS2) System RC RH C Y Y2 W/E W2 G O/B 6 L CLASS II TRANSFORMER HO T 24V AC NEUTRAL 120V AC Call for heat Heat mode-1st stage Heat mode-2nd stage No output 24 volt power f or cooling 24 volt power f or heatin ...

  • White Rodgers 1F95-1291 - page 4

    4 If you ha v e a single stage compressor system see the dia- gram belo w . A relay (customer provided) should be installed as shown in Fig 7 to s witch the fan speed to the ne xt lower speed on a call f or dehumidifi cation from the thermostat. The reduction in air fl o w allows the coil to remo ve more humidity from the air . The rela y should ...

  • White Rodgers 1F95-1291 - page 5

    5 Programming and Confi guration Items 1 Displa ys and "Keypad Loc kout" when in k eypad lock out mode. Displa ys and "T emperature Limit" and "Keypad Lock out" when limited range is activ ated and lock ed. Displa ys only "T emperature Limit" when limited range is activated. 2 Indicates period of day being p ...

  • White Rodgers 1F95-1291 - page 6

    6 INST ALLER/CONFIGURA TION MENU T o enter the menu: Press the Menu touch k ey . Press and hold f or 5 seconds the Installer Confi g touch ke y . This displays menu item #1 in the tab le below . Press to advance to the ne xt menu item or to return to a previous menu item. Press or to change a menu item option. CONFIGURA TION MENU Menu Reference Nu ...

  • White Rodgers 1F95-1291 - page 7

    7 INST ALLER/CONFIGURA TION MENU 1. This control can be confi gured f or : MS2 – Multi-Stage System (2 heat/2 cool) HP1 – Heat Pump with one stage of compressor (2 heat/1 cool) HP2 – Heat Pump with two stage compressor or two compressor system, Gas or Electric backup; (Dual Fuel see menu item 28) (4 heat/2 cool) SS1 – Single Stage System ( ...

  • White Rodgers 1F95-1291 - page 8

    8 12. Select Continuous Backlight – In low lighting condi- tions, displa y backlight improv es the displa y contrast. When C terminal is connected, selecting dL On will tur n the backlight on contin uously . Selecting dL Off will tur n the backlight on momentarily after any k ey is pressed. When C terminal is not powered (batter y only), dL On en ...

  • White Rodgers 1F95-1291 - page 9

    9 when you man ually raise the setting and want to allo w the thermostat to stage based on recent system performance. The F ast Cool feature operates the cooling stages in the same manner as F ast Heat, On or Off when the tempera- ture is lowered belo w the room setting. 27. Select Remote T emperature Sensor – Allows one wired remote temperature ...

  • White Rodgers 1F95-1291 - page 10

    10 cally reduces indoor humidity with a call f or Cooling if humidity is 2% abov e setting. Humidity is set by pressing the HUMIDITY ke y when in the appropriate mode, in this case Cooling , and pressing the or keys to set desired humidity le vel f ollowed by pressing Humidity key again. This dehumidifi cation f eature may use more energy by makin ...

  • White Rodgers 1F95-1291 - page 11

    11 Choose the System Setting (Cool, Off, Heat, Em, A uto) Press the SYSTEM ke y to select: Cool: Thermostat controls only the cooling system. Off: Heating and Cooling systems are off . Heat: Thermostat controls only the heating system. Em: Setting is av ailable only when the thermostat is confi g- ured in HP1 or HP2 mode. A uto: A uto Changeov er ...

  • White Rodgers 1F95-1291 - page 12

    12 PR OGRAMMING Set Current Time and Day 1. Press Menu ke y to enter installer menu. Then press Set Time once to indicate hour & AM or PM designation in clock displa y . 2. Press and hold either the or touch key until y ou reach the correct hour and AM or PM designation. 3. Press Set Time again to displa y minutes only in clock displa y . 4. Pr ...

  • White Rodgers 1F95-1291 - page 13

    13 PR OGRAMMING Planning Y our Program – Important The Heating and Cooling Program schedules belo w allow y ou to pencil in your o wn program times and temperatures . The 1F95-1291 comes confi gured f or 7 day progr amming and can also be confi gured f or 5+1+1 programming (see confi gur a- tion section). F actor y settings are listed on Monda ...

  • White Rodgers 1F95-1291 - page 14

    14 PR OGRAMMING Cooling Program W ake Up (Morning) Fan Leave For W ork (Day) Fan Return Home (Evening) Fan Go T o Bed (Night) Fan MON 6:00 AM 75°F A uto 8:00 AM 83°F A uto 5:00 PM 75°F Auto 10:00 PM 78°F A uto TUE WED THU FRI SA T 6:00 AM 75°F A uto 8:00 AM 83°F A uto 5:00 PM 75°F Auto 10:00 PM 78°F A uto SUN 6:00 AM 75°F A uto 8:00 AM 83? ...

  • White Rodgers 1F95-1291 - page 15

    15 Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 f eet). T erminals +, S and - on the terminal block allo w connection of the remote sensor . The thermostat must hav e 24 V AC Common connection to terminal C for the remo ...

  • White Rodgers 1F95-1291 - page 16

    16 www.white-rodgers.com White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co. HOMEO WNER HELP LINE: 1-800-284-2925 TR OUBLESHOO TING Symptom P ossible Cause Corrective Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power ...

Fabbricante White Rodgers Categoria Thermostat

I documenti che otteniamo dal fabbricante del dispositivoWhite Rodgers 1F95-1291 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici White Rodgers
- manuali per l’uso 1F95-1291
- schede prodotto White Rodgers
- opuscoli
- o etichette energetiche White Rodgers 1F95-1291
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso White Rodgers 1F95-1291.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione White Rodgers 1F95-1291, manuali di manutenzione, brevi manuali o manuali utente White Rodgers 1F95-1291. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto White Rodgers 1F95-1291.

Manuali per l’uso simili

Manuale completo del dispositivo White Rodgers 1F95-1291, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare White Rodgers 1F95-1291 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti White Rodgers 1F95-1291.

Il manuale per l’uso completo White Rodgers, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale White Rodgers 1F95-1291 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice White Rodgers 1F95-1291, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per White Rodgers 1F95-1291 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo White Rodgers 1F95-1291 - che ci dovrebbe aiutare nei primi passi durante l'uso White Rodgers 1F95-1291
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del White Rodgers 1F95-1291
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio White Rodgers 1F95-1291 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su White Rodgers 1F95-1291?

Utilizza il modulo sottostante

Se non hai risolto il problema con White Rodgers 1F95-1291 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con White Rodgers 1F95-1291 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)