-
Chauvet DMX5F - page 1
3000 N 29 th Ct, Holl ywood, FL 33020 U.S. A. (800 ) 762-10 84 – (954) 929-1115 FA X (954) 929 -5560 www.chauvetlighting.c om USER MANUAL Snapshot OK on Dimm er Outdoor OK Sound Activa ted DMX512 Master/Sl ave Autoswitching Transf ormer Repl aceab le F u se User Service ab le Duty Cycle ...
-
Chauvet DMX5F - page 2
Scorpion™ S t o r m RGX Us e r Manu al 2 4/27/2009 5:13 PM T ABLE OF C ONTENTS 1. Befor e You Beg in ................................................................................................................................ 3 W h at is i n clude d .............................................................................................. ...
-
Chauvet DMX5F - page 3
Scorpion™ S t o r m RGX Us e r Manu al 3 4/27/2009 5:13 PM 1. B EFORE Y OU B EGIN What is included 1 x Sc o r pion™ St orm RG X 1 x Power C ord 1 x W a rr anty Card 1 x Us e r Manu al Unpacking Instructions Immediat ely upon rec eiving a fixture, c are f ully unpack th e c a rt on, che ck the c ontents t o ensur e that all parts ...
-
Chauvet DMX5F - page 4
Scorpion™ S t o r m RGX Us e r Manu al 4 4/27/2009 5:13 PM Safety Instructions Plea s e keep this Us er Guid e for futur e consu ltation. If you sell t he unit t o another us er, b e sure that they als o receive th is instructi on booklet. Always make sur e that you are connecti ng t o th e pr ope r voltage, and th at the line voltag e you are co ...
-
Chauvet DMX5F - page 5
Scorpion™ S t o r m RGX Us e r Manu al 5 4/27/2009 5:13 PM NON -IN T ERLOCKE D HOUSING W A RNING This unit c ontains h igh pow er las e r d evices i nternally. D o not op en the laser housing, due t o p otenti al exposure t o uns a f e levels of l a s er rad iation. Th e las e r power l evels acc e ss ible if t he unit i s open ed can caus e inst ...
-
Chauvet DMX5F - page 6
Scorpion™ S t o r m RGX Us e r Manu al 6 4/27/2009 5:13 PM LASER SAFET Y L ABEL REPRO DUCTION LASER HA ZA RD W ARNING LAB EL LASER APERTURE LABEL EXP LAN ATORY, MANU FACTURER’S ID & CERTIFICATION LABEL NON INTERLOCKED HOUSING LABE L ...
-
Chauvet DMX5F - page 7
Scorpion™ S t o r m RGX Us e r Manu al 7 4/27/2009 5:13 PM LA SER LIGHT AV OID DIREC T EYE EXPOSURE Further gui delin e s and s a f e t y pr ograms f or safe us e of lasers c an be found in th e ANSI Z136.1 Stan dard “ For S a f e Use o f Lasers”, availabl e fr om the Laser Inst itute o f Am e r ic a : w ww.laseri nstit ute.org. Many loc al g ...
-
Chauvet DMX5F - page 8
Scorpion™ S t o r m RGX Us e r Manu al 8 4/27/2009 5:13 PM 2. I NTRODUCTIO N Features 4-channel DM X-5 12 c o ntr olled r ed and green eff ect laser Eff e ct m otor with c ontr o l of rot a ti on and st utter eff ect C o lor s election o f red, gr een or bot h red & g reen wit h s trob e control Built-in automat ic pr ograms via m a st er/sla ...
-
Chauvet DMX5F - page 9
Scorpion™ S t o r m RGX Us e r Manu al 9 4/27/2009 5:13 PM Product O v er view Power LED H a ngi ng bracket Bracket adjustm ent knob (1 of 2) Audio LED Laser Apert ure ...
-
Chauvet DMX5F - page 10
Scorpion™ S t o r m RGX Us e r Manu al 10 4 /27/2009 5:13 PM P RODUCT D IMENSI ONS ...
-
Chauvet DMX5F - page 11
Scorpion™ S t o r m RGX Us e r Manu al 11 4 /27/2009 5:13 PM P ROPER U SAGE CAU TION: Us e of c ontrols , adju stmen ts, or perfo rmance of procedu res o ther than wh at is sp ecifi ed here in may resu lt in haz ardous rad iat ion exposu re 3 meters CAUTI ON : Use of controls, adju stments, or performan ce of procedures other than what is specifi ...
-
Chauvet DMX5F - page 12
Scorpion™ S t o r m RGX Us e r Manu al 12 4 /27/2009 5:13 PM Th e fus e is locat ed inside this compartm ent. R e mo ve using a f lat head scr ewdriver. Han g ing Clamp Note! Clam p is sold s eparately . 3. S ETUP Fuse Replacement W ith a flat head sc rewdriver wed ge th e fus e holder out of its h ousing. Remo ve th e damag ed fuse fr om its hol ...
-
Chauvet DMX5F - page 13
Scorpion™ S t o r m RGX Us e r Manu al 13 4 /27/2009 5:13 PM Fixture Linking You wi ll need a s erial d ata link t o run light s hows of one or m o r e fi xtures using a D MX - 512 c ontroll e r or to run s ynchr onized shows on two or more fi xtures s e t to a mas ter/ slave oper ating mod e. The combined n umber o f chann els r equired b y all ...
-
Chauvet DMX5F - page 14
Scorpion™ S t o r m RGX Us e r Manu al 14 4 /27/2009 5:13 PM Th is drawing provid es a gen eral illu stration of the DMX I nput/ Output p anel of a ligh ting fixture. Universal D MX C ontroller Continue the link Often, the setup for M as te r-Sl ave and Standalone oper ation requires that the first fixture in the chain be initialized for this pur ...
-
Chauvet DMX5F - page 15
Scorpion™ S t o r m RGX Us e r Manu al 15 4 /27/2009 5:13 PM 4. O PERA TING I N ST RUCTIO NS Na vigating the Control Panel Access c ontrol p anel functions using th e f o ur p anel b uttons lo c ated di r e ctl y undern eath th e LE D Display. The C ontrol Pan el LED Dis play sh ow s the menu items you sel e ct fr om th e menu map on page # . W h ...
-
Chauvet DMX5F - page 16
Scorpion™ S t o r m RGX Us e r Manu al 16 4 /27/2009 5:13 PM DMX Channel Values C HANNEL V ALUE F UNCTI ON 1 000 0 19 020 0 39 040 0 59 060 0 79 080 0 99 100 1 19 120 1 39 140 1 59 160 1 79 180 1 99 200 2 55 Control M ode DMX Mo de Automatic fast (r ed) Automatic slow (r ed) Automatic fast (green) Autom ...
-
Chauvet DMX5F - page 17
Scorpion™ S t o r m RGX Us e r Manu al 17 4 /27/2009 5:13 PM S E T T I N G T H E S T A R T I N G A D D R E S S This DMX m ode enab les th e use o f a uni versal DM X c o n troller de vice. Eac h fixtur e requir es a "st a rt address " from 1 t o 512. A fi xtur e req uiring on e or m o r e ch ann els f o r c ontrol b egin s t o r ead the ...
-
Chauvet DMX5F - page 18
Scorpion™ S t o r m RGX Us e r Manu al 18 4 /27/2009 5:13 PM Technical Support Address: S ervic e D ept. 3000 N 29t h Ct, H ollywood, F L 33020 (U. S.A.) Support (E mail): t ech@ch auvetlighti ng.com Telephon e: (954) 92 9-111 5 - (Pr e ss 4) Fax: (954) 929-556 0 - (Atten tion: S ervic e ) W e bsite: h ttp://www.c hauvetli ghting.c om 5. A PPENDI ...
-
Chauvet DMX5F - page 19
Scorpion™ S t o r m RGX Us e r Manu al 19 4 /27/2009 5:13 PM Claims D a mage incurr ed in shippi ng is th e r e sp onsibility of the sh ipper; th eref o r e the damage must be reported t o the c a rr ier up on re c eipt o f m erchandis e. It is th e cust omer's r esponsibility t o notif y and submit claims with the sh ipp er in th e event th ...
-
Chauvet DMX5F - page 20
Scorpion™ S t o r m RGX Us e r Manu al 20 4 /27/2009 5:13 PM Technical Specifications WEIGHT & DIMEN SIONS Length ................................................................................................................................ . 11 in (2 76 mm ) W idth ........................................................................... ...
Hai una domanda su Chauvet DMX5F?
Utilizza il modulo sottostante
Se non hai risolto il problema con Chauvet DMX5F con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Chauvet DMX5F è probabile che voglia condividere il modo di risolverlo.