Manuale per l’uso Honeywell Q682

28 pagine 0.37 mb
Scarica

Vai alla pagina of 28

Summary
  • Honeywell Q682 - page 1

    Heating or Cooling Thermostat and W allplate or Heating/Cooling Thermostat and Subbase T8190A/191 108AJ, Q682 D.F. Rev. 9-94 ©Honeywell Inc. 1994 Form Number 69-0643—1 M3375 ...

  • Honeywell Q682 - page 2

    2 69-0643—1 M3375 Recyc ling Notice This control contains mercury in a sealed tube. Do not place control in the trash at the end of its useful life. If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Contact your local waste management authority for instructions regarding rec ...

  • Honeywell Q682 - page 3

    3 69-0643—1 Ta b le of Contents Page Features of Your Thermostat .................................................................................................... ........ 4 Setting the Temperature ....................................................................................................... ........... 7 Inserting Timer Batteries ... ...

  • Honeywell Q682 - page 4

    4 69-0643—1 Features Of Your Thermostat 1 FLIP-UP COVER. Lift it up to set clock for energy saving and normal temperature periods. 2 THERMOSTAT COVER. Lift up and remove to adjust heat anticipator. 3 THERMOMETER. Provides accurate room temperature reading. 4 TEMPERATURE SETTING LEVERS. Left (blue mark) controls the low temperature, right (red mar ...

  • Honeywell Q682 - page 5

    5 69-0643—1 8 PROGRAM INDEX WHEEL. Controls high and low temperature at specific time of day as set by program pins. 9 PROGRAM PINS. Must be inserted into 24- hour timer dial slots to control program index wheel. 10 PIN SLOTS. Located on 24-hour dial at 10- minute intervals for program pin insertion. 11 PROGRAM DIAL. 24-hour dial with light band ...

  • Honeywell Q682 - page 6

    6 69-0643—1 15 WALLPLATE (Included with thermostat.) Provides mounting base and wiring connections for heating-only or cooling-only thermostat. 16 SUBBASE (Optional, not included with thermostat; ordered separately.) Provides mounting base, wiring connections and manual switching control for heating/cooling thermostat. See Setting Subbase Switche ...

  • Honeywell Q682 - page 7

    7 69-0643—1 Fig. 1—Setting high and low temperature setting levers. Setting the T emperature For Heating: ■ Set the left lever (blue mark) to the energy saving temperature you want when you are sleeping or your home is unoccupied. ■ Set the right lever (red mark) to the tempera- ture you want for normal comfort periods. NOTE: You may overri ...

  • Honeywell Q682 - page 8

    8 69-0643—1 Inser ting Timer Batteries Power is supplied to the timer by the 24 Vac transformer, by two AAA alkaline batteries (included), or by the heating or cooling control circuit. Backup batteries may be installed to supply power to the timer if power is interrupted when using a 24 Vac powering method. Install batteries in thermostat as show ...

  • Honeywell Q682 - page 9

    9 69-0643—1 Setting the Timer ■ Lift thermostat flip-up cover and you’ll find the 24-hour program dial, slotted in 10-minute increments. Adjust the timer to the current time by carefully turning the knob clockwise . DO NOT reverse the knob. ■ When time is correctly set, the time indicator arrow (triangle shape) will point to the correct tim ...

  • Honeywell Q682 - page 10

    10 69-0643—1 Pr ogramming You can program your thermostat to automati- cally lower and raise the temperature one or more times every 24 hours, depending on the number of program pins used. Before setting your program Notice the slots on the program dial (Fig. 4). The dial is slotted for the program pins that can be inserted at 10-minute intervals ...

  • Honeywell Q682 - page 11

    11 69-0643—1 temperature (comfort period); a blue pin is inserted at 10:00 PM for low temperature (energy saving period). Two additional sets of pins are located in the program pin storage area. You can set up to six temperature changes with the pins supplied. We recom- mend at least five hours for each energy saving period. ■ To change the pin ...

  • Honeywell Q682 - page 12

    12 69-0643—1 To set the cooling program: ■ Decide when you want the temperature to reach the comfort level. Find the notch on the dial that is one-half hour before this time and insert a blue pin. The low temperature is in effect. The half-hour head start gives the air conditioner time to cool the house before you awaken or arrive home. ■ Dec ...

  • Honeywell Q682 - page 13

    13 69-0643—1 Setting Subbase Switches (if applicab le) The subbase system switch controls system operation as follows: HEAT—Heating system is controlled by the thermostat. Cooling system is off. COOL—Cooling system is controlled by the thermostat. Heating system is off. OFF—Both the heating and cooling systems are off. If the fan switch is ...

  • Honeywell Q682 - page 14

    14 69-0643—1 Tr oubleshooting Your Honeywell thermostat requires little or no attention. Most problems can generally be traced to the following. Problem Check Action No heat. — System switch may be in OFF Move system switch to HEAT position. or COOL position. — Fuse or circuit breaker. If blown or tripped, replace fuse or reset breaker. — F ...

  • Honeywell Q682 - page 15

    15 69-0643—1 Problem Check Action Energy saving — Program dial for proper day Turn timer ahead 12 hours. Turn temperature or night phase. knob clockwise only. program is 12 hours. Rooms do not — Timer program for heating Move red pin one-half hour earlier warm up at the system may need more time on the program dial. programmed to warm up room ...

  • Honeywell Q682 - page 16

    16 69-0643—1 Troubleshooting (Continued) Problem Check Action Room — Thermostat circuits. Heating mode—Move temperature temperatures setting levers 5 ° F [3 ° C] above room are not correct temperature. Heating system should (continued). start. Cooling mode—Move temperature setting levers 5 ° F [3 ° C] below room temperature. Cooling sys ...

  • Honeywell Q682 - page 17

    17 69-0643—1 No cooling. — System switch may be in OFF Move switch to COOL position. or HEAT position. — Fuse or circuit breaker. If fuse is blown or breaker tripped, replace or reset. If fuse blows again, call the heating and air conditioning dealer. — Condenser switch position. Move to ON position. Located outdoors and may be turned off. ...

  • Honeywell Q682 - page 18

    18 69-0643—1 Problem Check Action Thermostat setting — Level position of thermostat. Reinstall thermostat wallplate or and thermometer subbase. Use a spirit level. reading disagree. — Area around thermostat for Thermostat should be about 5 ft drafts or radiant heat. [1.5m] above floor on an inside wall. Contact qualified service technician fo ...

  • Honeywell Q682 - page 19

    19 69-0643—1 Timer does not — Voltage across the two C Remove thermostat from the wallplate run (continued). terminals. or subbase and measure the voltage. Refer to Voltage at Timer Terminals table for cause and reaction. — Pins in program dial. If pins are Push down on pins to make sure they not completely seated in are completely seated in ...

  • Honeywell Q682 - page 20

    20 69-0643—1 Problem Check Action Timer loses time — Batteries may need Replace with two new AAA alkaline (continued). replacement. batteries as shown in Fig. 2. 1 Not applicable on model used in heating-only system. 2 Not applicable on model used in cooling-only system. 3 If timer is not battery powered, timer may still use batteries for backu ...

  • Honeywell Q682 - page 21

    21 69-0643—1 Vo ltage At Timer Terminals AC Voltages at C-C Terminals Check Action 0 Vac. — System power off. — Restore power. — Short in timer power supply wiring. — Replace wiring. — Limit switch contacts stuck open. — Free or replace limit switch. — Transformer supplying power is — Replace transformer. burned out. Up to 15 Vac. ...

  • Honeywell Q682 - page 22

    22 69-0643—1 Servicing the Thermostat Cycle Rate Adjustment The equipment should cycle on and off just enough to keep the room temperature close to the temperature lever settings. If the thermostat seems to cycle the heating system too fast or too slow, adjust the cycle rate by moving the anticipator setting lever one indicator mark at a time (Fi ...

  • Honeywell Q682 - page 23

    23 69-0643—1 Thermometer Adjustment The thermometer was accurately calibrated at the factory and should only need adjustment if it has been dropped or mishandled. If the setpoint lever and the thermometer reading do not agree, follow the procedure below. Remove thermostat cover and open the flip-up cover. Set the thermostat cover on a table near ...

  • Honeywell Q682 - page 24

    24 69-0643—1 If you have questions regarding the installation and programming of your Honeywell thermostat, please visit our web site at www.honeywell.com/yourhome or call the 24-hour automated information line at 1-800-468-1502. ...

  • Honeywell Q682 - page 25

    25 69-0643—1 ...

  • Honeywell Q682 - page 26

    26 69-0643—1 ...

  • Honeywell Q682 - page 27

    27 69-0643—1 Limited One-Y ear W arranty Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell ...

  • Honeywell Q682 - page 28

    Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited/Honeywell Limitée 1985 Douglas Drive No. 740 Ellesmere Road Golden Valley, MN 55422 Scarborough, Ontario M1P 2V9 Printed in U.S.A. www.honeywell.com/yourhome ...

Fabbricante Honeywell Categoria Thermostat

I documenti che otteniamo dal fabbricante del dispositivoHoneywell Q682 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Honeywell
- manuali per l’uso Q682
- schede prodotto Honeywell
- opuscoli
- o etichette energetiche Honeywell Q682
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Honeywell Q682.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Honeywell Q682, manuali di manutenzione, brevi manuali o manuali utente Honeywell Q682. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Honeywell Q682.

Manuali per l’uso simili

Manuale completo del dispositivo Honeywell Q682, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Honeywell Q682 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Honeywell Q682.

Il manuale per l’uso completo Honeywell, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Honeywell Q682 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Honeywell Q682, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Honeywell Q682 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Honeywell Q682 - che ci dovrebbe aiutare nei primi passi durante l'uso Honeywell Q682
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Honeywell Q682
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Honeywell Q682 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Honeywell Q682?

Utilizza il modulo sottostante

Se non hai risolto il problema con Honeywell Q682 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Honeywell Q682 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)