Manuale per l’uso Olicom 9600

59 pagine 1.16 mb
Scarica

Vai alla pagina of 59

Summary
  • Olicom 9600 - page 1

    C HELIX TECHNOLO GY CORPORA TION - TI C RY OG EN ICS HELIX T ECHNOLOGY CO RPORATION http://www .helixtechnolo gy .com 9600 Compr essor Installation, Op eration, and Main ten anc e In stru ctio n s 8040540 Re v . 10 1 (12/2004) ...

  • Olicom 9600 - page 2

    ELIX H ©2004 He lix T echno logy Cor poratio n Pri nted in USA The infor mation in thi s documen t is believed to be accura te and reliabl e. However, Helix Technology Corpora tio n, cannot accept a ny fin ancial or other respo nsibiliti es that may result from the use of this infor mation. No warranti es are granted or extended by this document . ...

  • Olicom 9600 - page 3

    ...

  • Olicom 9600 - page 4

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 4 T a bl e of Co nt e nts Section 1 - 9 600 Compressor Description Ge n e ra l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 -1 Be ne fi t s . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Olicom 9600 - page 5

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce 5 P/N 8040 540 T a ble of Co nte nts ( con ti nue d) Section 3 - In stallat ion Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Supply and R eturn Water L ine Connections . . . . . . . . . . . . . . . . . ...

  • Olicom 9600 - page 6

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 6 T a ble of Co nte nts ( con ti nue d) App e ndi x A - Cu st ome r Su ppo rt Inf or m ation Appe ndi x B - Flow Diagram Appendi x C - Troubles hoot ing P r ocedures App e ndi x D - Sch e mat ic Figur es Figure 1- 1: 9600 Com pressor . . . . . . . . . . . . . . . . . . . ...

  • Olicom 9600 - page 7

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce 7 P/N 8040 540 T a ble of Co nte nts ( con ti nue d) Figure 5- 1: Disconnecting Self Sealing Couplings . . . . . . . . . . . . . . . . . . . . . . 5-2 Figure 5- 2: Adsorber Location within the 9600 C ompressor (R e ar Pan e l Rem ov e d ) . . . . . . . . . . . . . . . . . . . . . . . ...

  • Olicom 9600 - page 8

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 1-1 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Section 1 - 9600 Compr essor Description General This manual provides the information r equired to install, operate, and maintain the CT I-CR YOGENICS 9600 C ompressor . NOTE: All per sonnel with ins tallation, ...

  • Olicom 9600 - page 9

    9600 Compres sor Descri ption 1-2 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Syst em Documentation The ma nuals for a sy st em cover two bas ic c omponents: the cr yopump and the Compressor . A manual is shipped with e ach system component to provide information for ins tallation and ope ration of that compone nt. A loose- ...

  • Olicom 9600 - page 10

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 1-3 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Figure 1-1: 9600 C ompre ssor 9 6 0 0 C O M P R E S S O R C O M P R E S S O R 9 6 0 0 ...

  • Olicom 9600 - page 11

    9600 Compres sor Descri ption 1-4 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Speci ficat ions Di me ns io ns The dimensions of the Compres sor are shown in Fi gur e 1-2. Figure 1-2: 9600 Compr e ssor Dimensions CAUTION Do not place a we ight greater than 75 lbs. (34Kg) on top of the Compressor . 19.5 2 IN. (496 MM ) 21.50 ...

  • Olicom 9600 - page 12

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 1-5 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S We i g h t The weight o f the Com pressor is listed in T able 1-1. Electri cal The electri cal speci f icat i ons of the Compress or are listed in T able 1- 2. T able 1-1: Compressor W eight W e ight 200lbs./91k ...

  • Olicom 9600 - page 13

    9600 Compres sor Descri ption 1-6 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Cooling W at er The water used to cool the Compressor mus t meet the specifications sh own in T able 1-3 for proper syst em operation. Figur e 1-3: W at er Flow Rate versus Pressur e Dr op T able 1-3: Cooling W ater Specifications Parame ter V alu ...

  • Olicom 9600 - page 14

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 1-7 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S General The info rmation in T able 1-4 provides general Compressor operating specificat ions. NOTE: The 9600 Compr essor is des igned for continuous operation and should r emain ON when the cr yopumps ar e in a ...

  • Olicom 9600 - page 15

    9600 Compres sor Descri ption 1-8 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Component Description The components of the 9600 Compres sor that are acc essible f rom the rear panel are shown in Figure 1- 4 a nd described in the following par agraphs. Figure 1-4: 9600 Compre ssor Rear V iew Com ponent Locations CO NTROL CIRC ...

  • Olicom 9600 - page 16

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 1-9 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S System Circ uit Br eaker The System C ircuit Breaker protects main input power to the Compressor pump and module. The cir cuit breaker positions are labeled ON (1), which is in the UP position, and OFF ( 0), whi ...

  • Olicom 9600 - page 17

    9600 Compres sor Descri ption 1-10 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Retu rn Gas Coup ling The Return Gas C oupling returns t he helium, which has been cycled through the cryopump, back to the Compressor . Refer to CTI-CR YOGENICS Helium Re frigerat ion System within this section fo r m ore inf orma tion. Cooling ...

  • Olicom 9600 - page 18

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 1-1 1 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Cryopum p Pow e r Phase Switc h NOTE: The Cryopump Power Phase Switch is behind the system cir cuit br e a ker cover . The Cryopump Power Phase Switch matches the output power phase of the 9600 compressor to t ...

  • Olicom 9600 - page 19

    9600 Compres sor Descri ption 1-12 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Figur e 1-5: 9600 Compre ssor Connected to Multip le On-Bo ard Cryopumps NOTE: Y our installation (number of pum ps per compr essor) will vary based upon the On-Board C ryopumps or W aterpumps used. Refer to Appendix A to cons ult your l ocal CTI ...

  • Olicom 9600 - page 20

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 1-1 3 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Multipl e Cryo-T orr Cryop um p Conn ection s The Cryo-T orr Interface pe rmits the c onnection of multiple Cryo-T orr Cryopumps to one Compressor as s hown in Figure 1-6. Re fe r to Section 3 - I nstallation ...

  • Olicom 9600 - page 21

    9600 Compres sor Descri ption 1-14 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S ...

  • Olicom 9600 - page 22

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 2-1 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Section 2 - Unpacking and Inspection In trod ucti o n The 9600 Compres sor is shipped in a s hipping carton incorporating a ramp system which mak es remo ving the Compressor from the carton s afe and easy . Ship ...

  • Olicom 9600 - page 23

    Unpacki ng and Ins pe ction 2-2 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Figur e 2-1: U sing the Shipping Carton Ramp Co m pre ss o r In sp ec t i o n Inspect the Compressor for visible signs of damage as indicated in the follo wing paragraphs. Compressor Inspect the exterior of the Compr essor for visible signs of damag ...

  • Olicom 9600 - page 24

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 3-1 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Section 3 - Installation In trod ucti o n Section 3 pr ovi des you with the information required to ins tall the 9600 Compressor and connect it to si ngle or multiple On-Board or Cryo-T orr Cryopump conf igurati ...

  • Olicom 9600 - page 25

    In st al la ti o n 3-2 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Figure 3-1: 9600 Compressor I nstallation Flowchart Sup ply a nd Re turn Wat er Line Con nections (refer t o page 3-3) Electri cal C onnec tions (refer t o page 3-4) Phase C heck (ref er to pag e 3 -6) Si ng l e Cry opum p Co nn e ct i ons (ref er to pag e 3 ...

  • Olicom 9600 - page 26

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 3-3 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Suppl y a nd Retu rn W ater Lin e Con ne cti o ns NO TE: The water used f or cool i ng the Compr essor must meet the specif ications outlined in Section 1 - Compr essor Descrip tion . Hard W ate r L ines 1. Appl ...

  • Olicom 9600 - page 27

    In st al la ti o n 3-4 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Electri cal Connecti ons The follo wing procedures provide inf ormation for making a ll three phase (180 - 250 V A C) electrical connec tions to the Compressor . P ower Cable Pr eparati on W ARNING Follo w all local high voltage s afety precautions whe n per ...

  • Olicom 9600 - page 28

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 3-5 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Figure 3-2: 9600 C ompre ssor Circuit Break er T erminals (Cover Removed) NO TE: The phase order in which the conduc tor terminal lugs are connected to cir cuit br eaker terminals X, Y , and Z will be determined ...

  • Olicom 9600 - page 29

    In st al la ti o n 3-6 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Phase Check W ARNING Follo w all high voltage saf ety precautions when performing t his procedure to pre v ent the possibility of electrical shock. 1. Make sure power is applied to compressor cir cuit as de scribed in T able 1-2. NO TE: The cir cuit br eak e ...

  • Olicom 9600 - page 30

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 3-7 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Cryopump Po wer Ph ase Switch Sett ing NO TE: On-Boar d Cryopumps can operate on two or three-phase power . Cryo-T orr Cryopumps only operate on two-phase power . 1. Inspect the On-Board Cr yopump(s) being ins t ...

  • Olicom 9600 - page 31

    In st al la ti o n 3-8 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Disconnect in g 1. Using two wrenches as sho wn in Figure 3-3, disconnect the two self sealing coupling connectors quickly to mi nimize helium leakage. Figur e 3-3: Connecting/Disconnecting Helium Flex Line Self Sealing Couplings This 1 3/16 in. wre nch is u ...

  • Olicom 9600 - page 32

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 3-9 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Sing le On- B oar d C r yopu mp Con ne c ti ons CA UTION Make sure the Compressor power is OFF before making an y connections to the rear panel. 1. Connect the Supply and Return lines to the 9600 C ompressor as ...

  • Olicom 9600 - page 33

    In st al la ti o n 3-10 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Single Cry o-T orr Cry opump Con nections CA UTION Make sure the Compressor power is OFF before making an y connections to the rear panel. 1. Connect the Supply and Return lines to the 9600 C ompressor as described in Connect i ng/Discon n ect ing Helium Fl ...

  • Olicom 9600 - page 34

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 3-1 1 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Multipl e On-B oa rd Cryopum p Conn ection s CA UTION Make sure the Compressor power is OFF before making an y connections to the rear panel. Heliu m Line Connections CA UTION The use of se veral compressors o ...

  • Olicom 9600 - page 35

    In st al la ti o n 3-12 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S P ower Cable Connections 1. Connect the On-Board Splitter Box po we r cable between the CR Y OPUMP ELECTRICA L OUTLET on t he rear panel of the Compressor and the On-Board Splitter Box po we r connector as sho wn i n Figure 3- 6. 2. Connect the On-Board Cry ...

  • Olicom 9600 - page 36

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 3-1 3 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Figur e 3-7: Alter native Multipl e On-Board Cry op ump or W at e r pump Installation (Split ter Box located at Compr essor) Multiple Cry o - T orr Cry op ump Connections CA UTION Make sure the Compressor powe ...

  • Olicom 9600 - page 37

    In st al la ti o n 3-14 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S 1. Connect the Supply and Return lines to the 9600 C ompressor as described in Connect i ng/Discon n ect ing Helium Flex Lines within this section. 2. Connect the Gas Return Line to the customer s upplied helium manifold and then to the Gas Return connector ...

  • Olicom 9600 - page 38

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 3-1 5 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S NO TE: The Cryo-T or r Interface c an be installed at the proces s tool containing the cryopumps as s hown in F igur e 3-8 or ne ar the Compr essor as show n in F igur e 3-9. CTI-CR YOGENICS r ecommends that t ...

  • Olicom 9600 - page 39

    In st al la ti o n 3-16 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Figur e 3- 9: Alter nativ e Multiple Cry o-T orr Cryopump I n stallation CRY O PUMP PO WER CA BLES U SER R EMOTE (FROM V ACUUM SYSTEM) HELIUM SUPPL Y HELIUM RETURN WA T E R POWER CR Y O -T ORR INT ERF A CE REMOTE ...

  • Olicom 9600 - page 40

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 4-1 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Sect ion 4 - Oper ation Ad ju st ing Syst em He liu m Pr essur e Y our C TI-CR Y OGE NICS high vacuum pump system is comprised of se veral pressurized components i.e. compressor , flex lines, and cryopumps. Each ...

  • Olicom 9600 - page 41

    Operati on 4-2 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S NO TE: The use of a higher helium c har ge pr es sur e for 50 HZ operation is necessar y in or der to compens ate for the sl ower s peed at whi ch the compr e s sor operates at 50 HZ. The s tatic char ge le vel for 60 H z r e mains at 240-250 PSIG. CA UTION Exceedin ...

  • Olicom 9600 - page 42

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 4-3 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S If you hav e concerns about sys tem perf ormance changing, then check the normal system ope rating pr essure whic h was determ ined in Compressor Operat ion within this s ection. I f the norm al system operating ...

  • Olicom 9600 - page 43

    Operati on 4-4 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S ...

  • Olicom 9600 - page 44

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 5-1 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Secti on 5 - Maint en anc e Sc h edul ed Main tena n ce Suggeste d Ma intena nce Equipment It is r ecommended to ha ve the follo w ing equipment and disposable supplies a v ailable as listed in T able 5-1. T abl ...

  • Olicom 9600 - page 45

    Mainte nan ce 5-2 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Adsorber Rep lacem en t Use the following procedur e to change the adsorb er ev er y three year s. 1. Set the S y s tem Circuit Breaker , on the rear of the 9600 Compres sor , to the OFF position. 2. Remo ve the 4 screws which secure the rear panel to the Compres ...

  • Olicom 9600 - page 46

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 5-3 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S 9. Ensure that the press ure gauge reads the proper value as shown in T able 4-1. If additional gas pr essure is r equired, refer to A dding Heliu m within this section. If gas pressur e needs to be reduced, re ...

  • Olicom 9600 - page 47

    Mainte nan ce 5-4 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S Ad ju st ing Syst em He liu m Pr essur e NO TE: These pr ocedur es can be performed on a c ompr essor that is turned ON or OFF . However , the he lium pr essur e gaug e should be se t to the static helium c har ge pr e ssur e value if the compr essor is turned OF ...

  • Olicom 9600 - page 48

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 5-5 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S • T o the v alue pre viously recorded in the Compr esso r Ope rati on procedure in Section 4 - Operation if the compressor is ON. 3. Close the gas charge co ntrol v alve and install the flare cap. Incr easing ...

  • Olicom 9600 - page 49

    Mainte nan ce 5-6 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S 2. Pur ge the re gulator and charging lines as follo ws: a. Open the re gulator a small amount b y turning the adjusting knob clockwise unt il it contacts the diaphragm, t hen turn approximately 1/8 to 1/4 turn more, so that the re gulator is barely open. b . Loo ...

  • Olicom 9600 - page 50

    Document Ti tl e ELIX H ©2004 Heli x Technology Corpora tio n Pub. No. 8040509 , Rev. 101, 01/2 6/04 ECO No. 16210 A-1 Pr elimary Appe nd ix A - Cust omer Su pport Infor mation Customer Support Center Locations T o loca te a Customer S upport Center near you, please vis it our webs ite www .helixtechnology .com on the world wide web a nd select CO ...

  • Olicom 9600 - page 51

    ...

  • Olicom 9600 - page 52

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 B-1 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S A ppendix B - Flo w Diagram Figur e B-1:9600 Compres sor Flow Diagram ...

  • Olicom 9600 - page 53

    Appendi x B - Flow Diagram B-2 P/N 8 040540 ...

  • Olicom 9600 - page 54

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 C-1 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S A ppendix C - T rou bleshooting Pr ocedur es T roublesho oting t he Compressor The compressor troubleshooting procedur es ar e summarize d in T able C-1. T echnic a l I nqu irie s Ple a se r e fe r to A ppend ix ...

  • Olicom 9600 - page 55

    Appendix C - Trou bles hooting P rocedur e s C-2 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S T able C-1: Compressor T roubleshooting Procedures Problem Possible Cause Correctiv e Action 1) Sys tem ci rcuit br eaker (CB1) tri ps immedia tely to the O FF (0) position when switch ed to the ON (1) position. 1) Incorrect pha sin ...

  • Olicom 9600 - page 56

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 C-3 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S 3) Sys tem ci rcuit br eaker (CB1) will not remain in the ON (1) position wh en switch ed ON. The Control Circ uit c ircuit breaker ( CB2) trips w hen excessive current is being drawn by the cold head or 24 volt ...

  • Olicom 9600 - page 57

    Appendix C - Trou bles hooting P rocedur e s C-4 P/N 8040 540 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S ...

  • Olicom 9600 - page 58

    9600 Com pres sor In stal lati on, Operat ion, a nd Ma intena nce P/N 804054 0 D-1 C HELIX TECHN OLOGY CORPO RA T ION - TI C RY OG EN IC S A p pen d ix D - Sc he ma tic ...

  • Olicom 9600 - page 59

    Figur e D-1:9600 Mot or Driv e Compressor Schemati c ...

Fabbricante Olicom Categoria Air Compressor

I documenti che otteniamo dal fabbricante del dispositivoOlicom 9600 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Olicom
- manuali per l’uso 9600
- schede prodotto Olicom
- opuscoli
- o etichette energetiche Olicom 9600
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Olicom 9600.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Olicom 9600, manuali di manutenzione, brevi manuali o manuali utente Olicom 9600. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Olicom 9600.

Manuali per l’uso simili

Manuale completo del dispositivo Olicom 9600, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Olicom 9600 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Olicom 9600.

Il manuale per l’uso completo Olicom, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Olicom 9600 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Olicom 9600, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Olicom 9600 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Olicom 9600 - che ci dovrebbe aiutare nei primi passi durante l'uso Olicom 9600
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Olicom 9600
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Olicom 9600 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Olicom 9600?

Utilizza il modulo sottostante

Se non hai risolto il problema con Olicom 9600 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Olicom 9600 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)