Manuale per l’uso Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace

16 pagine 0.52 mb
Scarica

Vai alla pagina of 16

Summary
  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 1

    Upflo w/Horizontal Right or Upflo w/Horizontal Left Induced Draft Gas Furnace XR 80 TUD040,060,080,100,120,140C Single-Stage F an Assisted Comb ustion System PUB. NO . 22-1640-06-0702 (EN) FURN-PRC001-EN ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 2

    © 2002 American Standard Inc. All Rights Reserved 2 22-1640-06-0702 (EN) General Featur es Natural Gas Models Central Heating furnace designs are cer tified by the American and Canadian Gas Associations for both natur al and L.P . gas . Limit setting and rating data were estab lished and approved under standard rating conditions using American Nat ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 3

    22-1640-06-0702 (EN) 3 Contents General Features 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6 TUD040C924K 6 TUD040C930K 6 TUD060C924K 6 TUD060C936K 6 TUD080C924K 7 TUD080C936K 7 TUD080C948K 7 TUD080C960K 7 TUD100C936K 8 TUD100C945K 8 TUD100C948K 8 TUD100C960K 8 TUD100C972K 9 TUD120C954K 9 TUD120C960K 9 TUD140C9 ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 4

    4 22-1640-06-0702 (EN) Featur es and Benefits • P o wer supply 115/1/60 • Multi-por t In-shot b ur ners • Integrated solid state control with self diagnostics • Silicon Nitride hot surface igniter with adaptive heat up • Complete front service access • Heavy guage aluminized steel heat exchanger • Slide out bl ower assemb ly • Blowe ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 5

    22-1640-06-0702 (EN) 5 Optional Equipment Thermostat .............................................................................................................................................................. BA Y ST A T388 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Hor izontally) ....................................................... ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 6

    6 22-1640-06-0702 (EN) General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 For U . S. applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele vations abo ve 2,000 f ee t above sea lev el. F or Canadian applications, above input r atings (BTUH) are up to 4,500 feet, derate 4% per ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 7

    22-1640-06-0702 (EN) 7 General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 F or U.S . applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele v ations above 2,000 f ee t above sea le vel. F or Canadian applications, abov e input ratings (BTUH) are up to 4,500 feet, der ate 4% pe ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 8

    8 22-1640-06-0702 (EN) General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 For U . S. applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele vations abo ve 2,000 f ee t above sea lev el. F or Canadian applications, above input r atings (BTUH) are up to 4,500 feet, derate 4% per ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 9

    22-1640-06-0702 (EN) 9 General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 F or U.S . applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele v ations above 2,000 f ee t above sea le vel. F or Canadian applications, abov e input ratings (BTUH) are up to 4,500 feet, der ate 4% pe ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 10

    10 22-1640-06-0702 (EN) Per for mance Data FURN AC E AIRFLO W (CFM) VS. ST A TIC PRESSU RE (ins. w .g.) M OD EL SP EE D T AP 0.1 0 0.2 0 0.3 0 0.4 0 0.5 0 0.6 0 0.7 0 0.8 0 0 .90 TUD040C924K 4 - 3 - 2 - 1 - HIGH - Bla ck ME D . -HIGH - Blue ME D .-LO W - Y ello w LOW - Red 1018 847 716 617 1004 832 701 599 982 809 678 575 950 779 648 544 910 742 61 ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 11

    22-1640-06-0702 (EN) 11 Per for mance Data FURNACE AI RFL O W (C FM) VS. ST A T I C PR ESSURE ( i ns. w . g. ) M O DE L S P E E D T A P 0 .10 0 .20 0 .30 0 .40 0 .50 0 .6 0 0 .70 0 .80 0 .90 TUD1 00 C97 2K BO TTOM AND LEFT SIDE RET URN 4 - 3 - 2 - 1 - HI GH - Bl ack M E D .-H I G H - B lue M E D .-LO W - Y e l lo w LO W - Red 2484 2458 2432 2387 23 ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 12

    12 22-1640-06-0702 (EN) Field Wiring F rom Dwg. 21B341437 Rev . 1 F rom Dwg. 21B341436 Re v . 1 Field Wiring Diagram For Single Stage Heating/Cooling (Outdoor Section Without T ransformer) Field Wiring Diagram For Heating Onl y ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 13

    22-1640-06-0702 (EN) 13 F rom Dwg. 21B341423 Rev . 1 F rom Dwg. 21B341422 Rev . 1 T winning Field Wiring ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 14

    14 22-1640-06-0702 (EN) F rom Dwg. 21C341699 Re v . 1 TUD-C Outline Drawing (All dimensions are in inches) ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 15

    22-1640-06-0702 (EN) 15 Electrical Data Schematic Diagrams f or Gas Furnaces F rom Dwg. 21D341704 Rev . 1 ...

  • Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - page 16

    P .I. T rane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. T rane A business of American Standard Companies www .trane.com Literature Order Number FURN-PRC001-EN File Number — Supersedes TUD-D-1 3/98 Stocking Location PI Louisville & Webb/Mason-Hou ...

Fabbricante Trane Categoria Gas Heater

I documenti che otteniamo dal fabbricante del dispositivoTrane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Trane
- manuali per l’uso Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace
- schede prodotto Trane
- opuscoli
- o etichette energetiche Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace, manuali di manutenzione, brevi manuali o manuali utente Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace.

Manuali per l’uso simili

Manuale completo del dispositivo Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace.

Il manuale per l’uso completo Trane, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace - che ci dovrebbe aiutare nei primi passi durante l'uso Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace?

Utilizza il modulo sottostante

Se non hai risolto il problema con Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Trane Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)