  • Goodman Mfg IO-367B - page 1

    All information contained herein is subject to change without notice. I NST ALLA TION I NSTRUCTIONS F OR L IGHT C OMMERCIAL S ELF -C ONT AINED P ACKAGED H EA TING & C OOLING U NIT 15 & 20 T ON CPC RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. A TTENTION INST ALLING PERSONNEL Prior to installation, thoroughly familiarize yourself with this I ...

  • Goodman Mfg IO-367B - page 2

    2 REPLACEMENT PARTS O RDERING P ARTS When reporting shortages or damages, or ordering rep air part s, give the complete unit model and serial numbers as stamped on the unit’ s nameplate. Replacement parts for this appliance are available through your contractor or local distributor . For the location of your nearest distributor , consult the whit ...

  • Goodman Mfg IO-367B - page 3

    3 WARNIN G T O PREVE NT THE RISK OF PROPERT Y DAMAGE, PERSONAL INJUR Y, O R DEATH, DO NOT STORE COMB USTIBLE MATERI ALS OR USE GASOLI NE OR OTHER FLAM MA BLE L IQ UID S O R VA PO R S I N T H E V ICIN ITY OF THIS APPL IAN CE. HIG H  VO L T A G E ! I NSTALLATION  AND  RE PA I R  OF  THI S  UNIT  SHOUL D  BE  PERF ORME D  ...

  • Goodman Mfg IO-367B - page 4

    4 UNIT LOCA TION T O PRE VENT PO SSIBL E EQ UIPMEN T DAMAGE , PROP ERT Y DAMAG E , PERSO NAL INJURY OR DEATH , THE FOLLOW I NG BULLET PO INTS MU ST BE OBSE RVED WHEN INSTALLING THE UNIT . W ARNING IMPORT ANT NOTE: Remove wood shipping rails prior to installation of the unit. See important note under Roof Curb Installation Only . A LL I NSTALLATIONS ...

  • Goodman Mfg IO-367B - page 5

    5 • Do not skid or slide on any surface as this may damage unit base. The unit must be stored on a flat, level surface. Protect the condenser coil because it is easily damaged. R OOF C URB I NSTALLATIONS O NLY : Before installing this unit... IMPORT ANT NOTE: This unit has been equipped with a ship- ping brace under the compressor section that MU ...

  • Goodman Mfg IO-367B - page 6

    6 A LL CURBS LOOK SIM ILAR . T O AVOID INCO RRECT CURB PO SITI ONING , CHECK JOB PLANS CAREFU LLY AND VER IFY MARKIN GS ON CURB ASSEM BLY . I NSTRUC TI ONS MAY VARY IN CURB STY LES AND SUP ERSED ES INFORM ATION SHOW N . CAUTION See the manual shipped with the roof curb for assembly and installation instructions. CLEARANCES 36”; minimu m roof over ...

  • Goodman Mfg IO-367B - page 7

    7 RIGGING DET AILS WARN I NG T O PREVENT PROPERTY DAMAGE, THE UNI T SHOULD REMAIN IN AN UPRIGHT POSITION DURI NG ALL RIGGING AN D MOV ING OPERATIONS. T O FACILITATE LIFTING AND MOVING WHEN A CRANE IS USE D, PLACE THE UNIT IN AN ADEQUATE CABLE SL ING. D O NOT LIFT UNIT S TWO AT A TIME . P ROVI SION S FOR FORKS HAVE BEEN INCL UDED IN THE UNIT BASE FR ...

  • Goodman Mfg IO-367B - page 8

    8 CP C W e i g h t s (lbs ) CP C W eigh t s (l b s ) 1 5 T o ns 2 0 To n s Corner W e i gh t - A 580 655 Corner W e i gh t - B 540 535 Corner W e i gh t - C 475 510 Corner W e i gh t - D 440 420 Unit Shi ppi ng W eight 2150 2235 Unit O per ati ng W eigh t 2035 2120 X ( I n ches ) 60" 58 " Y ( I nche s) 43" 40 " DA TA NOTE: These ...

  • Goodman Mfg IO-367B - page 9

    9 CAUTIO N T O AVOI D PROPERTY DAMAGE O R PERSO NAL INJURY DUE TO FIRE , USE ONLY COPPER CO NDUCTORS. L ABEL ALL WIRES PRI OR TO DISCONN ECTI ON WHEN SER VIC ING CONTR OLS . W IRING ERRORS CAN CAUSE IMP ROPER AND DANG EROU S OPERATION . V ERI FY PR OPER OPERATION AFTER SER VIC ING . CAUTION NOTE: A weather-tight disconnect switch, properly sized fo ...

  • Goodman Mfg IO-367B - page 10

    10 3. Use #18 A WG wire for 24V control wiring runs not exceeding 75 feet. Use #16 A WG wire for 24V control wiring runs not exceeding 125 feet. Use #14 AWG wire for 24V control wiring runs not exceeding 200 feet. Low voltage wiring may be National Electrical Code (NEC) Class 2 where permitted by local codes. 4. Route thermostat wires from sub-base ...

  • Goodman Mfg IO-367B - page 11

    11 P RE -S TARTUP I NSTRUCTIONS T O PRE VENT PROP ERT Y DAMAG E OR PERSO NAL INJURY , D O NOT START THE UNIT UNTI L ALL NECE SSARY PRE - CHECK S AND TESTS HAVE BEEN PER FORM ED . CAUTION Prior to the beginning of S t artup, Adjustments, and Checks procedures, the following steps should be completed in the building. THERMOST A T . Set the thermostat ...

  • Goodman Mfg IO-367B - page 12

    12 System V oltage - That nominal volt age value assigned to a circuit or system for the purpose of designating its volt age class. Nameplate V olt age - That voltage assigned to a piece of equipment for the purpose of designating its voltage class and for the purpose of defining the minimum and maximum voltage at which the equipment will operate. ...

  • Goodman Mfg IO-367B - page 13

    13 R EFRIGERATION S YSTEM C HECKS Ensure the hold-down bolts on the compressor are secure and have not vibrated loose during shipment. Check that vi- bration grommets have been inst alled. Visually check all pip- ing and clamps. The entire refrigeration system has been factory charged and tested, making it unnecessary to field charge. Factory charg ...

  • Goodman Mfg IO-367B - page 14

    14 MOTOR SHEA VE ADJUSTMENTS V L , V M & 2 VP V ARIABLE P ITCH K EY T YPE M OTOR S HEAVES The driving and driven motor sheaves should be in align- ment with each other and the shafts p arallel. V L & V M S HEAVES A DJUSTMENT 1. Loosen set screw “B” using a 5/32" Allen key . 2. Making half or full turns from closed position, adjust ...

  • Goodman Mfg IO-367B - page 15

    15 C LEAN O UTSIDE C OIL (Q UALIFIED S ERVICER O NLY ) The coil with the outside air flowing over it should be inspected annually and cleaned as frequently as necessary to keep the finned areas free of lint, hair and debris. C ONDENSER , E VAPORATOR , AND I NDUCED D RAFT M OTORS Bearings on the air circulating blower motor , condenser mo- tor and t ...

  • Goodman Mfg IO-367B - page 16

    16 APPENDIX A BLOWER PERFORMANCE DA T A BEL T DRIVE - ST ANDARD NOTES: High static airflow requires installation of high st atic kit (HSKT240), or factory-built High S t atic model. Unit factory shipped with sheave set at 2.5 turns open. Air flow table represent dry coil with filters inst alled; SCFM correction factor for wet coil is 4%. CFM BH P C ...

  • Goodman Mfg IO-367B - page 17

    17 APPENDIX A BLOWER PERFORMANCE DA T A BEL T DRIVE - HIGH ST A TIC NOTES: High static airflow requires inst allation of high static kit (HSKT240), or factory-built High S t atic model. Unit factory shipped with sheave set at 2.5 turns open. Air flow table represent dry coil with filters inst alled; SCFM correction factor for wet coil is 4%. CFM BH ...

  • Goodman Mfg IO-367B - page 18

    18 APPENDIX B ELECTRICAL DA T A A TTENTION INST ALLING PERSONNEL Use only the heater kit specified for each model as dict ated by the t able above. MI N MAX Q ty R L A L RA Qt y H P R L A HP F LA 20 8/ 230 -60-3 1 8 7 253 2 33 .3 23 9. 0 3 1 / 3 2. 40 BD S T D STAT IC 5 . 0 12 .7 46 0 - 60 - 3 41 4 5 0 6 2 1 7. 9 1 2 5 . 0 3 1/ 3 1 . 2 0 B D S T D ...

  • Goodman Mfg IO-367B - page 19

    19 APPENDIX C UNIT DIMENSIONS VERTICAL DISCHARGE (TOP VIEW) 21” 60 ” 7” 48” 22” B C D A B C D A Mo d e l A BCD 15 T o n 20 T o n 133- 1/2" 88 - 7 / 3 2" 50 - 9 / 3 2" 5 - 5/ 32 " ...

  • Goodman Mfg IO-367B - page 20

    20 © 2010 Goodman Manufacturing Company , L.P . 5151 San Felipe, Suite 500 Houston, TX 77056 www .goodmanmfg.com www .amana-hac.com ...

Fabbricante Goodman Mfg Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoGoodman Mfg IO-367B possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Goodman Mfg
- manuali per l’uso IO-367B
- schede prodotto Goodman Mfg
- opuscoli
- o etichette energetiche Goodman Mfg IO-367B
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Goodman Mfg IO-367B.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Goodman Mfg IO-367B, manuali di manutenzione, brevi manuali o manuali utente Goodman Mfg IO-367B. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Goodman Mfg IO-367B.

Manuali per l’uso simili

Manuale completo del dispositivo Goodman Mfg IO-367B, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Goodman Mfg IO-367B dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Goodman Mfg IO-367B.

Il manuale per l’uso completo Goodman Mfg, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Goodman Mfg IO-367B - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Goodman Mfg IO-367B, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Goodman Mfg IO-367B che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Goodman Mfg IO-367B - che ci dovrebbe aiutare nei primi passi durante l'uso Goodman Mfg IO-367B
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Goodman Mfg IO-367B
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Goodman Mfg IO-367B in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Goodman Mfg IO-367B?

Utilizza il modulo sottostante

Se non hai risolto il problema con Goodman Mfg IO-367B con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Goodman Mfg IO-367B è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)