    FL 2242 Feb. 2000 BLAST CHILLERS MODEL NUMBERS CCBC-4-35 CCBC-12-75 CCBC12-UA-100 INSTALLATION, OPERATION & SERVICE MANUAL ...

  • Cres Cor CCBC-4-35 - page 2

    TABLE OF CONTENTS BLAST CHILLER INTRODUCTION Page 1 SECTION 1 DESCRIPTION Page 2 Chill Processing CCBC-4-35 Features and Specifications Page 3 CCBC-12-75 Features and Specifications Page 5 CCBC-12-UA-100 Features and Specifications Page 7 C o n t r o l P a n e l L a y o u t P a g e 9 SECTION 2 INSTALLATION Page 10 Unpacking and Installation Instruc ...

  • Cres Cor CCBC-4-35 - page 3

    INTRODUCTION [ Page 1 ] BLAST CHILLER INTRODUCTION THE BLAST CHILLER is the easiest and simplest way to chill f oods safely without addi tional labor. All food service operators prepare foods in advance or chill foods at the end of a workday. More often than not the foods are chilled in standard refrigerati on, often creating an unsafe time and te ...

  • Cres Cor CCBC-4-35 - page 4

    [ Section 1-Description ] [ Page 2 ] Chill Processing Under-Counter and Re ach-In Refrigerator/Storage Cabinet CCBC-4-35 The CCBC-4-35 is ideal for food service operations, wh ich require a small volume blast chiller. This model is capable of chilling 35 lbs. of food product to 38°F in approximately 90 minutes. Daily capacity is over 140 lbs. Of p ...

  • Cres Cor CCBC-4-35 - page 5

    [ Section 1-Description ] [ Page 3 ] CCBC-4-35 Chill Temp Blast Chiller Standard Features:  Stainless Steel Exterior and Interior  Two Operational Features: - Blast Chill Processing Refrigerator - 38°F Storage Refrigerator  Operational Indicator Panel with Mic roprocessor: - Blast Chill Cycle Controlled Automatically by E ither a Food Pro ...

  • Cres Cor CCBC-4-35 - page 6

    [ Section 1-Description ] [ Page 4 ]  Flush Mounted Doors, Anti-Condensation Heaters and Removable Magnetic Door Gaskets  Four (4) Pairs of Adjustable Pans lides for 12" x 20" x 2 1/2" Pans  Heavy Duty Casters  Hot Gas Condensate Vaporization  Large Surface Area Evaporat or and High Velocity Fan  CFC Free R-134A Ref ...

  • Cres Cor CCBC-4-35 - page 7

    [ Section 1-Description ] [ Page 5 ] CCBC-12-75 Reach-In Blast Chill Standard Features:  Stainless Steel Exterior and Interior  Two Operational Features: - Blast Chill Processing Refrigerator - 38°F Storage Refrigerator  Operational Indicator Panel with Mic roprocessor: - Blast Chill Cycle Controlled Automatic ally by Either Food Probes o ...

  • Cres Cor CCBC-4-35 - page 8

    [ Section 1-Description ] [ Page 6 ] - Power Failure Alarm - Three (3) Food Probes with Digital Temperature indicator  Seven (7) Day Temperature Recorder with Printout Dem and  Stainless Steel Front, Side s, Door and Interior  Flush Mounted Doors, Anti-C ondensation Heaters and Remova ble Magnetic Door Gaskets  Twelve (12) Pairs of Adju ...

  • Cres Cor CCBC-4-35 - page 9

    [ Section 1-Description ] ________[ Page 7 ] The CBBC-12-UA-100 Reach-In Blast Chiller Standard Features Stainless Steel Exterior and Interior  Two Operational Features: - Blast Chill Processing Refrigerator - 38°F Storage Refrigerator  Operational Indicator Panel with Mic roprocessor: - Full Microprocessor Controlled by a Digital Timer (con ...

  • Cres Cor CCBC-4-35 - page 10

    [ Section 1-Description_] ___ ____[ Page 8 ] - On/Off Switch with Bl ast Cycle and Cancel Button - Digital Temperatur e Display and Defrost Indicator - Power Failure Alarm - Food Probe with Digital Temperature Indicator  Galvanized Stee1 Top Stainless Stee l Top, Front, Sides, Door and Liner  Flush Mounted Doors, Anti-Condensation He aters an ...

  • Cres Cor CCBC-4-35 - page 11

    [ Page 9] Control Panel For CCBC-4-35 1. Select Chill Mode 2. Select Hard or Soft Blast 3. Select Timer for pro be or time of process 4. When satisfied with selections, press Check to Start Cycle 5. Press if you want to erase and start programming over Control Panel For CCBC-12-75 & CCBC-12-UA-100 1. Select Chill Mode 2. Select Hard or Soft Bla ...

  • Cres Cor CCBC-4-35 - page 12

    [ Section 2-Installation ] [ Page 10 ] UNPACKING INSTRUCTIONS IMPORTANT: It is high ly recommended that your refrigerator or freezer be installed by an authorized CresCor Service Agency (List enclosed) A. Receiving Shipment Upon arrival, examine the exte rior of the shipment packaging for any signs of rough handling. If the cabinet is damaged, it s ...

  • Cres Cor CCBC-4-35 - page 13

    [ Section 2-Installation ] [ Page 11 ] C. Removing Plastic Film Stainless steel surfaces are protect ed with plastic f ilm when shi pped. The film is easily removed by grasping an edge corner of the film and pulling it off . D. Locating Your new Blast Chill Unit The cabinet should not be placed in the immediat e vicin ity of ranges, ovens and other ...

  • Cres Cor CCBC-4-35 - page 14

    [ Section 2-Installation ] [ Page 12 ] 3. Make sure cabinet is sitting level with all f our (4) casters (o r legs) in contact with the floor. 4. Also make sure the door stays open when opened past 90 degrees. 5. Inspect magnetic door gasket to be sure it is making contact on all four (4) sides. Also make sure it is not cut, tor n, twisted or otherw ...

  • Cres Cor CCBC-4-35 - page 15

    [ Section 3-Operation ] [ Page 13] GENERAL OPERATION OF BLAST CHILLER All CRESCOR BLAST CHILLERS have 3 basic modes: 1. Normal refrigeration storage 1°C/34°F to 3°C/38°F 2. Blast chill hard –10°C/14°F 3. Blast chill soft 1°C/34° Normal Cycle 1°/34°F to 3°C/38°F This is the storage temperature at which the food can be held. Blast Chill ...

  • Cres Cor CCBC-4-35 - page 16

    [ Section 3-Operation ] [ Page 14 ] 6) By pressing button ‘3’, select the Timer for the desired duration or pr obed blast. Default to probe blast unless it is known how long a product will chill. 7) If a variety of products are used make sure one probe is strategically placed near the top shelf, 1 in the center and 1 at a lower shelf. If a vari ...

  • Cres Cor CCBC-4-35 - page 17

    [ Section 3-Operation ] [ Page 15] To activate a blast chill cycle you must: 1. Choose the required store mode with button 1 2. Choose the require blast type with button 2 (select hard blast unless all ite ms chilling are delicate) 3. Choose the blast duration or probe with button 3 (select probe unless you know how long it take s the product to ch ...

  • Cres Cor CCBC-4-35 - page 18

    [ Section 3-Operation ] [ Page 16] If a blast cycle is cancelled and the defrost thermostat is m easuring 1°C/32°F or less, the BLAST CHILLER automatically goes into a defrost cycl e. When the BLAST CHILLER is in the defrost mode the “Cab inet Temp” window of the control panel will display “DEF” During the defrost cycle some fans will sto ...

  • Cres Cor CCBC-4-35 - page 19

    [ Section 3-Operation ] [ Page 17] PRINTER If equipped, the printer is activated af ter each blast cycle. The printer provides hard copy historical data of cabinet performance or warning tickets to archive or act upon. The following formats are available: Midnight Ticket At midnight, a ticket is automatically printed for archiving in the morning. T ...

  • Cres Cor CCBC-4-35 - page 20

    [ Section 4- Maintenance ] [ Page 18 ] CAUTION ! HINTS: 1. Turn Off Blast Chiller 1. Use the mildest cleaning product that will 2. Allow Cabinet to warm slight ly. do the job 3. Do not hose Blast Chiller. 2. Always rub in the dire ction of polish lines to Avoid scratching the surface.  Wipe up spills as soon as possible. 3. Use only a soft cloth ...

  • Cres Cor CCBC-4-35 - page 21

    [ Section 5- Troubleshooting ] [ Page 19 ] SERVICE & TROUBLESHOOTING  Setting or Resetting Time and Date SET UP PROCE DURE SWI TCH FUNCTION I N S PECI AL SWITCH MODE I/O ON/O FF SWITCH 1 W hen held i n, dis plays the code f or cur rent param eter 2 Step back to pr evious par amet er, and whil e held in dis plays the param eter code. W hen re ...

  • Cres Cor CCBC-4-35 - page 22

    [ Section 5- Troubleshooting ] [ Page 19a ] ALARM CODES 7-Segment Display The left hand window shows the cabinet wall temperature. The right hand displays show the probe temperatur es during a blast cycle, and are norm ally blank during store. If a probe fails it will indicate pf (probe failure) during a blast. Cab temp window also acts as a count ...

  • Cres Cor CCBC-4-35 - page 23

    [ Section 5- Troubleshooting ] [ Page 20 ]  Cabinet has no power to c ontroller-display not lit: 1. Make sure the power is connected to the cabinet that the cord is plugged in on the models with power cord and plug. 2. Check main circuit breaker at power supply panel; make sure it is on. 3. Model CCBC-12-UA-100 only, has an "isolator" ...

  • Cres Cor CCBC-4-35 - page 24

    [ Section 5- Troubleshooting ] [ Page 21 ] 3. Compressor runs continuously. (1) Check compressor for "pumping" efficiency. (2) Door not closed tig ht or gasket leaking. (3) If no DPC, or if DPC set too low to open, check refrigerant charge and/or thermostatic expansi on valve for adequate feeding.  Cabinet has power, display shows &quo ...

  • Cres Cor CCBC-4-35 - page 25

    [Section 5-Troubleshooting ] [ Page 22 ] 2. Door not shut tight 3. Gaskets leaking 4. Check defrost heater operator (if used): (a) Defective heater (b) Blown fuse (if used) (c) Defective "klixon" if used 5. Check defrost settings: (a) Check defrost thermostat ("St 5") setting (b) Check defrost differential ("dt 5") set ...

  • Cres Cor CCBC-4-35 - page 26

    [ Section 5-Troubleshooting ] [ Page 23 ] (c) Check make sure ribbon car tridge is properly installe d - both sides snapped in place 4. Printer is printing backwards and all characters reversed (a) Paper tape is feeding inc orrectly over top of printer ribbon. This can readily occur when inserting a ribbon cartridge w ith paper tape still protrudin ...

  • Cres Cor CCBC-4-35 - page 27

    [ Section 6 – Parts and Drawings ]________ ______________ __ [ Page 24 ] Parts List and Breakdown Drawing of Blast Chillers ...

  • Cres Cor CCBC-4-35 - page 28

    [ Page 25 ] ...

  • Cres Cor CCBC-4-35 - page 29

    [ Page 26 ] PARTS LIST CCBC-4-35 BLAST CHI LLER 208V 60HZ SINGLE PHASE Drawing Number Description Part Number 1 COMPRESSOR CAJ 4492Y R134A WCOMP 345 1a CONDENSER 3X11X21 WCOND 250 1b DRIER 1/4 X 3/16 SWEAT T R134A WDRIER 110 1c SIGHT GLASS 1/4" SWEAT WSIGHT 020 2 RECEIVER 2.2 L WRECEIVER 060 3 EXPANSION VALVE BODY TEN 2 R134A WVALVE 196 3 1/4& ...

  • Cres Cor CCBC-4-35 - page 30

    [ Page 27 ] ...

  • Cres Cor CCBC-4-35 - page 31

    [ Page 28 ] PARTS LIST CCBC-12-75 BLAST CHILLER 208V 60HZ SINGLE PHASE Drawing Number Description Part Number 1 COMPRESSOR FH4518 Y 208/220V 60HZ WCOMP 365 1 CONDENSER 4X17X17.5 WCOND208 3 EVAPORATOR FAN MOTOR 4X200MM AXIAL FAN ZIEHL WFAN 115 3 FLAT GUARD WGUARD 080 3 1.5 UF CAPACITOR 230V 60HZ WCAPACITOR 050 4 EVAPORATOR 4X12X41 WEVAP311 5 SIGHT G ...

  • Cres Cor CCBC-4-35 - page 32

    [ Page 29 ] ...

  • Cres Cor CCBC-4-35 - page 33

    [ Page 30 ] PARTS LIST CCBC-12-UA-100 BLAS T CHILLER 208V 60HZ 3 PHASE Drawing Number Description Part Number 1 COMPRESSOR TFH 4524Z 2 08/230V 60HZ WCOMP 833 2 CONDENSER 4X17X17.5 WCOND 208 3 EVAPORATOR FAN MOTOR 4X200MM AXIAL FAN ZIEHL WFAN 115 3 FLAT GUARD WGUARD 080 3 1.5 UF CAPACITOR 230V 60HZ WCAPACITOR 040 4 EVAPORATOR 5X45X16 WEVAP348 5 SIGH ...

  • Cres Cor CCBC-4-35 - page 34

    General Rules of Thumb [ Page 31 ]  Pre-Chill the cabinet for thirty (3 0) minutes before you do first load. (to remove interior residual heat)  Doubling the food thickness triples the pull-down time.  Don't stack food or containers on t op of or alongside of each other. (this increases the "thickness)  Covering the food incre ...

  • Cres Cor CCBC-4-35 - page 35

    Contact Information [ Page 32 ] Please Send Serial registration information to : Fax: (800) 378 – 8333 E-mail to: parts&service@crescor.com Or Mail To: CresCor 5925 Heisley Road Mentor, OH 44060 Toll Free: 877-273-7267 Fax: 440-350-7267 See us online at: http://www.crescor.com Questions? Call and Speak To One Of Our Friendly Service Counselor ...

  • Cres Cor CCBC-4-35 - page 36

    [ Page 33 ] Notes __________________ _____________________ ___________________ __________________ _____________________ ___________________ __________________ _____________________ ___________________ __________________ _____________________ ___________________ __________________ _____________________ ___________________ __________________ ________ ...

  • Cres Cor CCBC-4-35 - page 37

    [Page 34] MEATS * Roasted Meats Roasted meats should be prepared according to the recipe using roast gui delines for each product. Roast Beef (top round) - Follow recipe and roast guidelines. Recommended doneness for rethermalization is about 140° F. (60° C.). To p round should be quartered and placed in the blast chiller. If roast beef is used f ...

  • Cres Cor CCBC-4-35 - page 38

    [Page 35] Seafood Fish - Prepare all fish fillets according to recipe for breaded, baked, broiled, steamed, etc. Be careful not to overcook. Blast chill immediately. Shrimp/Scallops/Shellfish - Prepare according to recipe and blast chill immediately. Be careful not to overcook. If prepared with a sauce (creole, etc.), cook the sauce separate and mi ...

  • Cres Cor CCBC-4-35 - page 39

    [Page 36] SOUPS Conventional Soup Prepare conventionally. For creamed soups, s ubstitute a modified starch for a portion of the thickening agent by 30 to 50%. Canned Soup No cooking is necessary for broth based soups. Cream soups should be diluted with milk or water, mixed completely, and blast chilled. Frozen Soup Follow instructions on the soup c ...

  • Cres Cor CCBC-4-35 - page 40

    [Page 37] Broccoli/Cauliflower/Green Beans/Carrots Prepare green beans and carrots in bite size and broccoli and cauliflower in flowerets. Steam to desired doneness, then blast chill. Stuffed Vegetables (eggplant, zucchini) Prepare stuffing and blast chill. Steam shell and blast chill or place in ice bath. Stuff vegetable shell and blast chill to b ...

  • Cres Cor CCBC-4-35 - page 41

    [Page 38] RICE Prepare according to standardized recipe, then blast chill. If rethermalized product is dry, liquid may be added. PASTA AND NOODLES Cook to al dente, rinse well w ith cold water, then chill. Chill in 2-1/2" pans with water with ice added. Drain partially before rethermi ng. The best way to heat pasta is to run it under hot water ...

  • Cres Cor CCBC-4-35 - page 42

    [Page 39] • Add a 2" perforated insert to pan. • Break eggs (25-30) in separate bow l and slip onto the 1/2 pan insert. • Steam a maximum of 3 minutes (time s hould be tested at each facility as equipment performance will vary at each location). • Lift perforated insert out of pan and plunge into ice wate r to retard cooking. The white ...

  • Cres Cor CCBC-4-35 - page 43

    [Page 40] BREAKFAST BURRITOS/CREPES Burrito and crepe filling is prepared conventio nally and chilled. When filling is chilled, then fill crepes and burritos. Blast chill filled products. BREAKFAST SANDWICHES Prepare sandwich filling separately and chill. Assemble sandwiches, wrap, and blast chill for additional 15-20 minutes. HASH BROWNS/OVEN FRIE ...

Fabbricante Cres Cor Categoria Refrigerator

I documenti che otteniamo dal fabbricante del dispositivoCres Cor CCBC-4-35 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Cres Cor
- manuali per l’uso CCBC-4-35
- schede prodotto Cres Cor
- opuscoli
- o etichette energetiche Cres Cor CCBC-4-35
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Cres Cor CCBC-4-35.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Cres Cor CCBC-4-35, manuali di manutenzione, brevi manuali o manuali utente Cres Cor CCBC-4-35. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Cres Cor CCBC-4-35.

Manuali per l’uso simili

Manuale completo del dispositivo Cres Cor CCBC-4-35, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Cres Cor CCBC-4-35 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Cres Cor CCBC-4-35.

Il manuale per l’uso completo Cres Cor, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Cres Cor CCBC-4-35 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Cres Cor CCBC-4-35, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Cres Cor CCBC-4-35 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Cres Cor CCBC-4-35 - che ci dovrebbe aiutare nei primi passi durante l'uso Cres Cor CCBC-4-35
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Cres Cor CCBC-4-35
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Cres Cor CCBC-4-35 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Cres Cor CCBC-4-35?

Utilizza il modulo sottostante

Se non hai risolto il problema con Cres Cor CCBC-4-35 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Cres Cor CCBC-4-35 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)