    Reference Manual Part Number: MAN -0 0 81 , re v. 4 Release : Ju ly 2014 Net Saf et y JB Series Junc tion Bo x ...

  • Emerson Process Management rev. 4 - page 2

    ...

  • Emerson Process Management rev. 4 - page 3

    Impor tant I nstruc tions Net Safe ty Monitori ng, Inc (Net Safety) des igns , manufactures and tests products to function within spec ific c ond itions . B ecaus e th ese produ cts a re s oph ist icated t ech nic al in stru men ts , it is im por tant that the owner and operation personnel must strictly adhere both to the information printed on the ...

  • Emerson Process Management rev. 4 - page 4

    N otic e The con tent s o f this pu blica tion are pres ente d for infor m ation al pur pos es on ly, an d w hile every effort has been made to ensure their accuracy, they are not to be construed as warranties or guaran te es, ex press ed or i mplie d, re gar ding t he pr od uct s or service s des cri bed h er e in or their use or applic ab ility . ...

  • Emerson Process Management rev. 4 - page 5

    W arrant y 1. Lim ited W arr anty . Subject to the li mitations contained in Section 10 (Lim ita tion of Rem edy and Lia bi lity) her ein, S elle r war rant s th at (a ) the lic ense d firm war e em bodi ed in t he Goods will ex ecut e t he pr ogra mmi ng ins tru cti ons pr ovid ed by Se ller; (b) th at t he G oods manufactured by Seller will be fr ...

  • Emerson Process Management rev. 4 - page 6

    ...

  • Emerson Process Management rev. 4 - page 7

    Referenc e Manual Table of Co ntent s MAN - 0081, Revisi on 4 July 2014 Table of C onten ts I Con tent s Sectio n 1 : Intro duction ....................................................................... 1 1.1 Mod els cov ered .................................................................................................................. 1 1.2 S ...

  • Emerson Process Management rev. 4 - page 8

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 II Table of C onten ts 7.1.4 Relay contacts (JB - IR3SA R) ................................................................................. 19 7.2 Environmental .................................................................................................................. 19 7.2.1 Storage te m ...

  • Emerson Process Management rev. 4 - page 9

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 1 Section 1 : Intr oduction 1.1 Models covere d The Net Safety JB ser ies jun ct ion box is a mu lti - purpose junction box that is used with numerous Net Safety products. It can be used as a termination box for flame detectors or for remote mounting gas senso rs fr om t rans mitt ers. It is avail ...

  • Emerson Process Management rev. 4 - page 10

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 2 1.3 Return of material To expedite the repair and return of this product, proper communication between the customer and the factory is important. Before returning a product for repair, call + 1866 347 342 7 or e- mai l safety.csc @emerson.com for a Material Return Authorization (MRA) number. On ...

  • Emerson Process Management rev. 4 - page 11

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 3 Section 2 : Insta llation 2.1 Unpacking and inspe ction Carefu lly rem ov e all o f the c ompon ent s f rom th e pack agin g an d ver ify t hem again st the en clo sed packing list. Inspect all components for any obvious damage such as broken or loose parts. If you find any components missing or ...

  • Emerson Process Management rev. 4 - page 12

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 4 2.4 Wiring Failure t o follow these installat ion guidelines could result in death or serious injury. Ensure that only qualif ied personnel perform the inst allation. Electr ical shock coul d caus e de ath or seri ous in jury . U se ext reme cauti on when makin g cont act with the lea ds a nd te ...

  • Emerson Process Management rev. 4 - page 13

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 5 Seals s hou ld b e loc ate d as c lose t o t he dev ice a s po ssi ble and n ot m ore th an 18 inc hes (46c m) a way ; seal a ll co ndu its w ithin 18 i nch es (4 6cm). Cons ult the l ocal elect rica l co de f or sp ecif ic re quir ement s. Explos ion proo f inst alla tio ns may requ ire an a dd ...

  • Emerson Process Management rev. 4 - page 14

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 6 2.4.4 Ground connect ions The junctio n box is equipped with an internal and external earth groun d lu g. One c rimp c onne ctor is provi ded for ea ch gr ound lu g. On inst allat ion , crim p th e grou nd w ire to cr imp c onn ector an d then securely fasten crimp connector to ground lug. See F ...

  • Emerson Process Management rev. 4 - page 15

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 7 Section 3 : Terminal board configur ations There a re m ulti ple t erm inal boar d con figu rati ons facil it ated by th e JB s eries junc tio n b ox. T his allo ws effect ive, sa fe , and accurate terminations and sensor separation requirements across the Net Safety product line. These configur ...

  • Emerson Process Management rev. 4 - page 16

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 8 3.1.2 Model s: UVS - AR, and UV/IRS - AR 3.1.3 Models: IR3S -A Flame dete ctor wi rin g Terminal Color Functi on B Blue Manua l Vi/ MV I R Red 4- 20mA S igna l BLK Black COM ( -) W White Vdc (+ ) Green Earth Ground Power an d ou tput wiring Terminal Functi on RRst Remote Res et MVI Manual VI SIG ...

  • Emerson Process Management rev. 4 - page 17

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 9 3.1.4 Models: IR3S -D 3.1.5 Models: IR3S - AD Flame dete ctor wiring Terminal Color Functi on 1 (GN D) Green Earth ground 2 Red Vdc (+ ) 3 Black COM ( -) 4 Blue A (Com m) 5 Brown B (Com m) 6 Not used 7 Not used Power an d ou tput wiri ng Terminal Functi on 1 (GN D) Earth ground 2 Vdc (+ ) 3 COM ...

  • Emerson Process Management rev. 4 - page 18

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 10 3.1.6 Models: IR3S -R Flame dete ctor wi rin g Terminal Color Functi on 1 (GN D) Green Earth ground 2 Red Vdc (+ ) 3 Black COM ( -) 4 Orange Alarm relay 5 Orange Alarm rela y 6 Violet Fault relay 7 Violet Fault relay Power an d ou tput wiri ng Terminal Functi on 1 (GN D) Earth ground 2 Vdc (+ ) ...

  • Emerson Process Management rev. 4 - page 19

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 11 3.1.7 Models: IR3S - AR By de fault t he F ault rela y is fixe d as En erg ized a nd Non - latch ing a nd ca nnot be ch a nge d. The defau lt sett ing for the Alarm re lay is De - ener giz ed an d Non - latching. The current loop jumper pins at J 6 are not jum pered by defau lt. If 4 - 20 mA is ...

  • Emerson Process Management rev. 4 - page 20

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 12 3.2 Gas detection In the follo win g dra win gs, t he sensor wiring s ide r efer s t o the w irin g betwe en the gas transmitter and the junction box terminals. The transmitter wiring sid e refer s to wirin g b etwee n th e transmitte r and the junction box terminals. 3.2.1 Models: Millen nium ...

  • Emerson Process Management rev. 4 - page 21

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 13 3.2.2 Millennium SIR100 and APM 3.2.3 Millennium ST1 toxic sensor series Sensor wirin g Terminal Color Functi on 1 (GN D) Green Earth ground 2 White Vdc (+ ) 3 Black COM (-) 4 Blue A (Com m) 5 Red B (Com m) 6 Not used 7 Not used Transmi tter wiring Terminal Functi on 1 (GN D) Earth ground 2 Vdc ...

  • Emerson Process Management rev. 4 - page 22

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 14 3.2.4 Millennium SC 1 combustible sensor serie s 3.2.5 Millennium ST2 & Gas Shield ST7 toxic sensor ser ies Sensor wirin g Terminal Color Functi on 1 (GN D) Green Earth ground 2 White Vdc (+ ) 3 Red Signal 4 Black COM ( -) 5 Not used 6 Not used 7 Not used Transmi tter wiring Terminal Functi ...

  • Emerson Process Management rev. 4 - page 23

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 15 3.3 Common junction boxe s 3.3.1 HART Port remote connection b ox (JB - MPH - A/S ) The HART Port connector plugs onto the PCB board. The Black wire is a safety ground. Connect the black w ire to e arth g round. When no e arth g roun d is av a ilabl e conn ect the black wire t o the loo p commo ...

  • Emerson Process Management rev. 4 - page 24

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 16 Section 4 : M aintenance 4.1 Troubleshooti ng The junction box is not d esign ed to be r epair ed in th e fiel d. I f pro blem s sho uld dev elop, first ch eck for fau lty wir ing and c onfir m pr oper volt ag e to the ju nction box . I f pro blem s per sist , pleas e con tact Net Safe ty’s t ...

  • Emerson Process Management rev. 4 - page 25

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 17 Section 5 : El ectrostatic se nsitive device Defin ition : El ectr osta tic disc harge (ESD ) is t he t rans fer, bet ween b odie s, o f an e lec tros tat ic char ge caus ed by dir ect cont act or indu ced by an elect rost atic fiel d. The m ost c ommo n cau se o f E SD is phys ica l conta ct . ...

  • Emerson Process Management rev. 4 - page 26

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 18 Section 6 : Wi re resistance table Distan ce Feet ( Meters) AWG #20 0.5mm 2 AWG #18 0.8mm 2 AWG #16 1.0mm 2 AWG #14 2.0mm 2 100 (3 0.5) 1.02 0.64 0.40 0.25 200 (6 1) 2.03 1.28 0.80 0.51 300 (9 1.4) 3.05 1.92 1.20 0.76 400 (1 21.9 ) 4.06 2.55 1.61 1.01 500 (1 52.4 ) 5.08 3.20 2.01 1.26 600 (1 82 ...

  • Emerson Process Management rev. 4 - page 27

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 19 Section 7 : Specifications 7.1 Electrical 7.1.1 Operat ing voltage 10 to 3 2 Vd c 7.1.2 Condu it entries 3 x 3/4” NPT 7.1.3 Power consumption (J B -IR3SAR) Nomina l: 170m A (1. 7W ) @10Vdc Maxim um: 2 75m A ( 2.9W) @ 10 Vdc Nomina l: 73m A (1. 8W) @ 24V dc Maxim um: 1 17m A ( 2.8W) @ 24 Vdc 7 ...

  • Emerson Process Management rev. 4 - page 28

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 20 7.2.6 We i ght A luminum: 2 .0 lbs , 0. 8 kg Stain less st eel: 3. 5lbs , 1.6k g 7.3 War ranty 2 years ...

  • Emerson Process Management rev. 4 - page 29

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 21 Section 8 : Ce rtifications 8.1 North America Clas s I, Divis ion 1 Grou ps B ,C , D T5 Class I, Zon e 1 Ex d I IB +H 2 T5 (Canada) Class I, Zon e 1 AE x d IIB +H 2 T5 (United States) - 55 °C ≤ Ta + 8 5°C NEMA Type 4X/IP67 8.2 ATEX 0575 II 2G Ex d IIB +H 2 T5 Gb - 55 °C ≤ Ta + 85 °C IP6 ...

  • Emerson Process Management rev. 4 - page 30

    Referenc e Manual July 2014 MAN - 0081, Revisio n 4 22 Section 9 : Ordering informatio n Model Descr ipt ion JB Multi - pu rpos e te rmin atio n box Type Performance IR3S AR 4- 20mA A na log an d F ire & F ault Relay s ( IR3S o nly ) MPD Digita l Out put (Gas Sens ors & APM Only ) MPG General junction box MPH Us ed to se parate r emote H AR ...

  • Emerson Process Management rev. 4 - page 31

    Referenc e Manual MAN - 0081, Revisi on 4 July 2014 23 Notes: ...

  • Emerson Process Management rev. 4 - page 32

    MAN -0 081 Revisi on 4 July 2014 Emerson P rocess Manag ement Net Safety Monito ring Inc. 2721 Hopewe ll Place NE Calgary, Alberta, Canad a T1Y 7J7 T +1 (403) 219 0688 T +1 866 347 3427 F +1 (403) 219 0694 www.emerson process.c om/ safety © 2014 Emerson Process Manageme nt. All rights reserved . Emerson Process Management, Rosemount Analytical, an ...

Fabbricante Emerson Process Management Categoria Automobile Electronics

I documenti che otteniamo dal fabbricante del dispositivoEmerson Process Management rev. 4 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Emerson Process Management
- manuali per l’uso rev. 4
- schede prodotto Emerson Process Management
- opuscoli
- o etichette energetiche Emerson Process Management rev. 4
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Emerson Process Management rev. 4.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Emerson Process Management rev. 4, manuali di manutenzione, brevi manuali o manuali utente Emerson Process Management rev. 4. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Emerson Process Management rev. 4.

Manuale completo del dispositivo Emerson Process Management rev. 4, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Emerson Process Management rev. 4 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Emerson Process Management rev. 4.

Il manuale per l’uso completo Emerson Process Management, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Emerson Process Management rev. 4 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Emerson Process Management rev. 4, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Emerson Process Management rev. 4 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Emerson Process Management rev. 4 - che ci dovrebbe aiutare nei primi passi durante l'uso Emerson Process Management rev. 4
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Emerson Process Management rev. 4
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Emerson Process Management rev. 4 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Emerson Process Management rev. 4?

Utilizza il modulo sottostante

Se non hai risolto il problema con Emerson Process Management rev. 4 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Emerson Process Management rev. 4 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (1)

richard rivero

hola buenas tarde tengo una pfaff 130-6 necesito el manual para descargar en español por favor