    OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL “ SE ” ...

  • Hubbell Electric Heater Company " SE " - page 2

    2 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659 FAX: (203) 378-3593 INTERNET: http://www.hubbellheaters.com/ -- IMPORTANT -- Always reference the f ull model num ber and serial number when calling the factory. WARNING / CAUTION 1. Tank is to be complete ly fille d with water and a ll air is to be vente d bef ...

  • Hubbell Electric Heater Company " SE " - page 3

    3 TABLE OF CONTENTS SECTION TITLE PAG E # I GENERAL DESCRI P TI ON AND CONSTRUCTION 5 II INSTAL LATI ON 10 III S C H E D U LE D M A IN TE NANC E AND OPERATION 12 I V TROUBL ES HOOTI NG 14 V SERVICI NG AND REPLACEMENT OF PARTS 16 VI MI SCELL ANEOUS C HARTS AND FORMULAS 24 ...

  • Hubbell Electric Heater Company " SE " - page 4

    4 ...

  • Hubbell Electric Heater Company " SE " - page 5

    5 SECTION I - GENERAL DESCRIPTION AND CONST RUCTION GENERAL DESCRIPTION This book describes a packaged electric water heater that is a stationary, self-contained unit. The complete assembly consists of the storage tank, immersion electric heating element(s), thermostat, safety relief valve, safety high temperature cut out, magnetic contactor(s), an ...

  • Hubbell Electric Heater Company " SE " - page 6

    6 CONTROL THERMOS TAT The water heater is supplied with either a surface mounted or immersion thermostatic switch that is installed and wired at the factory . See drawing for specific details. The surface mounted thermostat can be adjusted through a range of 110° - 170° F . The immersion thermostat can be adjusted through a range of 100° - 190° ...

  • Hubbell Electric Heater Company " SE " - page 7

    7 MAGNETIC CONTACTOR The magnetic contactor(s) is a heavy -duty resistive load ty pe rated for 100,000 cy cles. T he co nt act o r su ppl i es p ow er t o t he hea ti ng e le men t( s) and is si z ed b as ed on t he resistive load (non-inductive) rating of the circuit. The contactor supplies power on ly whe n t he t he rm os ta ti c s wit ch is en ...

  • Hubbell Electric Heater Company " SE " - page 8

    8 Fused Low Voltage Transformer A fused low voltage transformer may be supplied. This option is used to step down higher voltages to 120-volt for the control circuit. Dial Temperature an d Pressure Gauge A combination temperature (70° - 250° F) and pressure (0 – 200 psi) gauge with 2½-inch dial may be supplied for in-line installation (shipped ...

  • Hubbell Electric Heater Company " SE " - page 9

    9 On/Off Switch A built-in non-fused On/Off disconnect switch may be supplied with the control panel to disconnect power to the control panel control and power circuit wiring. Individually Fused Ele me nts To prevent the possibility of damag e to circuits and elements in c ase of electrical overloa ds, fuses may be supplied for each circuit. Two ty ...

  • Hubbell Electric Heater Company " SE " - page 10

    10 SECTION II – INSTALLATION WARNING / CAUTION DO NOT TURN ON THE ELECTRI C POWER SUPPL Y to this equipment until heate r is completely filled with water and all air has been re leased. If the heater is NOT fille d with water when the power is turned on, the heating elements will burn out. For protection against excessive pressures and temperatur ...

  • Hubbell Electric Heater Company " SE " - page 11

    11 Outlet to floor drain Install into provided tapping Manual Release Lev e r Temperature Probe Temperature and Pressure Relief Valve 5. I nstall a relief valve overflow pipe to a nearby floor drain. CAUTION: No valve of any ty pe should be installed between the relief valve and tank or in the drain line. FILLING THE HEATER 1. Completely close the ...

  • Hubbell Electric Heater Company " SE " - page 12

    12 SECTION III - SCHEDULED MAINTE NANCE AND OPERATION WARNING / CAUTION Before performing any maintenance procedure, make certain power supply is OFF and cannot accidentally be turned on. MAINTENANCE AND OPERATION The water heater is automatic in its operation. I t will maintain a full tank of water at the temperature setting of the thermostat. The ...

  • Hubbell Electric Heater Company " SE " - page 13

    13 ANNUAL INSPECTION 1. Flush tank as follows a. Shut off power supply . b. Close valve on hot water outlet piping. c. Open valve on drain piping. d. Cold water inlet line pressure will be strong enough to flush sediment from the bottom of the tank out through the drain. L et water run for 3-4 minutes. e. Close drain valve. f. Open hot water valve. ...

  • Hubbell Electric Heater Company " SE " - page 14

    14 SECTION IV – TROUBLESHOOTING Symptom Probable Cause Corrective Action / Remedy Circuit breaker tripped at source. Reset circ uit breaker. On/Off switch in ‘OF F’ position, if installed. Turn switch to ‘ON’ position. Circuit breaker at control cabinet trippe d, if installed. Reset circ uit breaker. Blown fuse in element fuse block, if i ...

  • Hubbell Electric Heater Company " SE " - page 15

    15 Faulty thermostat. Chec k thermostat adjustment. Monitor thermostat as described in S e ct i o n III, Q u a rt e r l y In s p e c t i on. Replace if necessary. Blown fuse in element fuse block, if installed. Replace fuse. Heating element not worki ng on all phases Check to see th at heating element is working on all phases, by checking the resis ...

  • Hubbell Electric Heater Company " SE " - page 16

    16 SECTION V - SERVICING & REPLACEMENT OF PARTS WARNING / CAUTION Before servicing or replacing any part make sure to turn the power supply switch to the OF F position. SURFACE TEMPERATURE HIGH LIMIT CUT -OFF 1. Disconnect power from unit. 2. Remove access cover. 3. Disconnect the four (4) 14 gauge wires. Control Wires 4. Remove the two (2) mou ...

  • Hubbell Electric Heater Company " SE " - page 17

    17 IMMERSION TEMPERATURE HIGH L IMIT CUT-OFF 1. Disconnect power from unit. 2. Remove access cover. 3. Remove high limit c over screw and cover. Cover Cover Screw Reset Switch 4. Disconnect the two (2) 14 gauge wires. Wires Capillary Tube 5. Remove capilla ry tube a nd bulb from thermowell 6. Remove two (2) mounting screws. Mounting Screws 7. Remov ...

  • Hubbell Electric Heater Company " SE " - page 18

    18 HEATING ELEM ENT 1. Disconnect power from unit. 2. Shut off incoming water supply . 3. Attach hose to drain connection. 4. Lift manual release lever on relief valve to let air into sy stem or break union on outgoing water line. 5. Drain water from tank. 6. Disconnect the wires from the heating elem ent terminal s. 7. Remove the 3/8-16 nuts. Tank ...

  • Hubbell Electric Heater Company " SE " - page 19

    19 ...

  • Hubbell Electric Heater Company " SE " - page 20

    20 SURFACE MOUNTED THE RMOSTAT 1. Disconnect power from unit. 2. Remove access cover and locate t hermostat. 3. Disconnect the two (2) 14 gauge wires. Control Wires 4. Remove two (2) mounting screws. Mounting Screws 5. Replace thermost at using the reverse procedure. ...

  • Hubbell Electric Heater Company " SE " - page 21

    21 IMMERSION THE RMOSTAT 1. Disconnect power from unit. 2. Remove access cover and locate t hermostat. 3. Remove high limit c over screw and cover. Cover Cover Screw 4. Disconnect the two (2) 14 gauge wires. Wires Capillary Tube 5. Remove capilla ry tube a nd bulb from thermowell. 6. Remove two (2) mounting screws. Mounting Screws 7. Replace thermo ...

  • Hubbell Electric Heater Company " SE " - page 22

    22 MAGNETIC CONTACTOR 1. Disconnect power from unit. 2. Disconnect line and load wires to contactor. 3. Disconnect two (2) 14 gaug e control circuit wires. Control Wires Line Wires Load Wires 4. Loosen two (2) holding screws and remove contactor. Mounting Screws (Bottom screw not shown) 5. Replace with new cont actor using reverse procedure. ...

  • Hubbell Electric Heater Company " SE " - page 23

    23 RELIEF VALVE 1. Disconnect power from unit. 2. Shut off incoming water supply . 3. Lift test lever on relief valve to relieve pressure in tank. 4. Disconnect overflow piping. 5. Unscrew relief valve, remove assemb ly and repl ace with new one. 6. Connect overflow piping. 7. Turn on incoming water supply and check for leaks. 8. Turn safety switch ...

  • Hubbell Electric Heater Company " SE " - page 24

    24 SECTION VI – MISCELL ANEOUS CHARTS AND FORMULAS ELEMENT CHA RT Resistance (Ohms) Element Part # I mmersion L ength Hairpin 1 Φ 3 Φ DELTA 3 Φ WYE 2-38683N 13" 57.6 19.2 57.6 38.6 3-38683N 13" 43.2 14.4 43.2 28.9 4-38683N 13" 34.4 11.5 34.4 23.0 5-38683N 13" 27.9 9.3 27.9 18.7 6-38683N 13" 21.6 7.2 21.6 14.5 7-38683N ...

  • Hubbell Electric Heater Company " SE " - page 25

    25 TORQUE VALUE S BOLT SIZE 18-8 S/S IN. - LB S . BRASS IN. - LB S . SI LI CON BRONZE IN. - LB S . ALUMI NUM 2024-T4 IN. - LB S . 316 S/S IN. - LB S . MONEL IN. - LB S . 4-40 5.2 4.3 4.8 2.9 5.5 5.3 4-48 6.6 5.4 6.1 3.6 6.9 6.7 5-40 7.7 6.3 7.1 4.2 8.1 7.8 5-44 9.4 7.7 8.7 5.1 9.8 9.6 6-32 9.6 7.9 8.9 5.3 10.1 9.8 6-40 12.1 9.9 11.2 6.6 12.7 12.3 8 ...

Fabbricante Hubbell Electric Heater Company Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoHubbell Electric Heater Company " SE " possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Hubbell Electric Heater Company
- manuali per l’uso " SE "
- schede prodotto Hubbell Electric Heater Company
- opuscoli
- o etichette energetiche Hubbell Electric Heater Company " SE "
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Hubbell Electric Heater Company " SE ".

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Hubbell Electric Heater Company " SE ", manuali di manutenzione, brevi manuali o manuali utente Hubbell Electric Heater Company " SE ". A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Hubbell Electric Heater Company " SE ".

Manuale completo del dispositivo Hubbell Electric Heater Company " SE ", come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Hubbell Electric Heater Company " SE " dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Hubbell Electric Heater Company " SE ".

Il manuale per l’uso completo Hubbell Electric Heater Company, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Hubbell Electric Heater Company " SE " - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Hubbell Electric Heater Company " SE ", FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Hubbell Electric Heater Company " SE " che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Hubbell Electric Heater Company " SE " - che ci dovrebbe aiutare nei primi passi durante l'uso Hubbell Electric Heater Company " SE "
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Hubbell Electric Heater Company " SE "
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Hubbell Electric Heater Company " SE " in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Hubbell Electric Heater Company " SE "?

Utilizza il modulo sottostante

Se non hai risolto il problema con Hubbell Electric Heater Company " SE " con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Hubbell Electric Heater Company " SE " è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)