Zephyr AK8800AG - page 1
Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: Date of Purchase: Sales Dealer: AUG08.0101 © 2008 Zephyr Corporation W illow AK8800AS AK8800AG READ AND SA VE THESE INSTRUCTIONS INTENDED FOR OUTDOOR COVERED P A TIO OR LANAI AREA. ...
-
Zephyr AK8800AG - page 2
www .zephyronline.com ...
-
Zephyr AK8800AG - page 3
1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ..................... ...
-
Zephyr AK8800AG - page 4
Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY T O PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the man ...
-
Zephyr AK8800AG - page 5
Important Safety Notice 3 CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place. Without these components, operating blowers could catch onto hair , fi ngers and loose clothing ...
-
Zephyr AK8800AG - page 6
List of Materials 4 www .zephyronline.com MODELS: AK8800AS AND AK8800AG P ARTS SUPPLIED 1 - 316S High quality stainless steel Power Pack (AK8800AS) or 1 - Gray powder coated Power Pack (AK8800AG) 2 - Baf fl e fi lters 2 - Halogen light bulbs (pre-installed) 1 - Dual internal blower (pre-installed) 1 - 8” round adapter 1 - Hardware package HARDW ...
-
Zephyr AK8800AG - page 7
5 Installation – Ducting Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft . x ( ) = Ft. 7”-10” Round, straight 1 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 flat elb ow ...
-
Zephyr AK8800AG - page 8
Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 8” round ducting must be used to maintain maximum air fl ow ef fi ciency . Always use rigid type metal ducts only . Flexible ducts could restrict air fl ow by up to 50%. Also use calculation (on page 5) to compute total available duct run when using e ...
-
Zephyr AK8800AG - page 9
7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only . Fasten all connections with sheet metal screws and tape all joints with certi fi ed Silver T ape or Duct T ape. Some Ducting Options Installation ? ...
-
Zephyr AK8800AG - page 10
8 www .zephyronline.com Installation – Speci fi cations top side front C L 11 7/16 ” 13/16” 2 5/8 ” 14 11 / 1 6 ” 15 13/16 ” 2 3/8 ” 14 3/4 ” 24 5/8 ” 25 15/16 ” 29 13/16 ” 1 5/16 ” 1 1/2 ” C L elec. k/o 5” 7 3/4 ” 4 3/8 ” 1 1/2 ” 1 3/4 ” elec k/o 6 1/2 ” 15 13/16 ” 14 11 / 1 6 ” 11 7/16 ” 11 7/16 ” 4 ...
-
Zephyr AK8800AG - page 11
9 ELECTRICAL W ARNING All Electrical work must be performed by quali fi ed electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing ...
-
Zephyr AK8800AG - page 12
10 www .zephyronline.com Installation – Installing the Power Pack Remove support screw from top of Power Pack before installing into cabinet. FIG 2b 1. Place 8” round adapter on top of power pack and secure with (4) M4x8 screws. (FIG 3) 2. Install optional AK088xAS Stainless Steel Liner under custom hood opening. Review manual included with lin ...
-
Zephyr AK8800AG - page 13
11 Light On/Off By pressing , the light is switched On and Off. is on, is off. Blower Speed Selection The 2 speed levels are selected by switching to for level one and for level two. Lights On/Off Adjust Blower Level (2 Speeds) 1 1 2 2 Switching the rocker switch to middle will turn off the blower. Controls – Rocker Switch Controls ...
-
Zephyr AK8800AG - page 14
12 www .zephyronline.com Maintenance – Cleaning and Installing Filters SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier s ...
-
Zephyr AK8800AG - page 15
13 Maintenance – Lights REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, ...
-
Zephyr AK8800AG - page 16
14 www .zephyronline.com T roubleshooting TROUBLESHOOTING PROCEDURES FOR WILLOW Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the power con ...
-
Zephyr AK8800AG - page 17
List of Parts and Accessories 15 DESCRIPTION P ART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baf fl e Filter (each) 50210010 Optional Accessories Liner , 36” AK0886AS Liner , 42” AK0882AS Liner , 48” AK0888AS Liner , 54” AK0884AS Liner , 60” AK0880AS T o order parts, visit us online at http://store.zephyronline.com o ...
Hai una domanda su Zephyr AK8800AG?
Utilizza il modulo sottostante
Se non hai risolto il problema con Zephyr AK8800AG con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Zephyr AK8800AG è probabile che voglia condividere il modo di risolverlo.