Manuale per l’uso HP Extech 380976

20 pagine 1.1 mb
Scarica

Vai alla pagina of 20

Summary
  • HP Extech 380976 - page 1

    User Guide 1 Φ /3 Φ 1000 Amp True RMS Power Clamp-On Model 380976 ...

  • HP Extech 380976 - page 2

    380976 V3.2 4/11 2 Introduction Congratulations on your purchase of the Ext ech 380976 Power Cla mp-On Meter. This device measures 1 Φ /3 Φ Power (True, Ap parent, and Reactive), Horsepo wer, Phase Angle, True RMS Current/Voltage, Resistance, Capacitance, Freque ncy, & Temperature. Power meas urements can be achieved on 3- or 4-wire config ur ...

  • HP Extech 380976 - page 3

    380976 V3.2 4/11 3 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for on e year from date of shipment (a six month limited warranty applies to sensors and cables). If it should bec om e necessary to return the instrument for service during or beyond the warranty period, contact the Cu ...

  • HP Extech 380976 - page 4

    380976 V3.2 4/11 4 Meter Description 1. Transformer Jaws 2. Jaw opening trigger 3. Data Hold & MX/MN button 4. Function Selector 5. Range button 6. Temperature input jack 7. LCD Display 8. ‘COM’ input jack 9. ‘ V ’ input jack 10. Ω µA input jack ...

  • HP Extech 380976 - page 5

    380976 V3.2 4/11 5 Measurements AC + DC Voltage Measure ments WA R NI NG The maximum input is 600V. Do no attempt vo ltage measurements above this limit. Exceeding this limit could cause electrical sh ock and damage to the meter. 1. Set the rotary switch to the ‘ V’ position. 2. Insert the test leads into the meter’s input jacks. (Black to ? ...

  • HP Extech 380976 - page 6

    380976 V3.2 4/11 6 AC Power Measurements 1 Φ KW, KVA, KV A R, Pow er Factor & Phase Angle Measurement 1. Set the rotary switch to the ‘KW/KVA’ position. 2. Insert the test leads to the meter as follows: Black to ‘COM’ and Red to ‘V’. 3. Connect the black lead to the neutral line. 4. Connect the red lead to the power line and clamp ...

  • HP Extech 380976 - page 7

    380976 V3.2 4/11 7 3 Φ 3-Wire KW, HP, KVA, KVAR, Pow er Factor & Phase Angle Measurement 1. First, measure W RS(L1 L2) (refer to the diagram be low). a. Set the rotary switch to the “ V ”. b. Press and hold the “ HOLD ” key while setting the rotary switch to “KW/KVA”, the 3 φ 3W and W L12 symbols will appear. c. Insert the test le ...

  • HP Extech 380976 - page 8

    380976 V3.2 4/11 8 3. The power clamp will process these tw o sets of data (W L12 , W L23 ), and show the result on the LCD. The W L123 symbol will be shown to indicate 3 φ 3W power. The 3 φ 3W power (in watts) is stored in the meter memory. 4. To read a single data record, press the “ HOLD ” key to select des ired W L12 , W L23 or W L123 dis ...

  • HP Extech 380976 - page 9

    380976 V3.2 4/11 9 NOTE Once a phase is selected as COM, user s can not change this selection in the subsequent measurement. For example, if S (or L2) phase is selected, S (or L2) phase is always connected to t he COM during measurement of W RS (or W L1L2 ) and W TS (or W L3L2 ) in 3 φ 3W unbalanced power. NOTE 1. The "+" sign printed on ...

  • HP Extech 380976 - page 10

    380976 V3.2 4/11 10 3 Φ 4-Wire KW, HP, KVA, KVAR, Pow er Factor & Phase Angle Measurement 1. First, measure W R(L1) (refer to t he diagram below). a. Set the rotary switch to the “ V ” position. b. Press and hold the “ RA NG E ” key while setting the rotary switch to the “KW/KVA” position, the 3 φ 4W and W L1 s ymbols should appea ...

  • HP Extech 380976 - page 11

    380976 V3.2 4/11 11 3. Third, measure W T(L3) (refer t o the diagram that follows the steps below) a. Disconnect the test probe from the phase wher e th e jaws were clamped in the previous measurement. b. Connect the test probe of the V (red) terminal to th e third phase (e.g. T or L3 phase). c. Clamp the phase where the test probe is connected to ...

  • HP Extech 380976 - page 12

    380976 V3.2 4/11 12 4. The power clamp will proce ss these t hree sets of data ( W L1, W L2 W L3 ) and s how the r esult o n the L CD. The WL 123 symbol will be s hown to indic ate the 3 φ 4W power (r efer to di agram) . The 3 φ 4W power value in w atts is now stored in the meter’s memory. 5. To read a s ingle data re cord , use the “ HOLD ? ...

  • HP Extech 380976 - page 13

    380976 V3.2 4/11 13 KW+KVA R, KVA+ θ ( Phase A ngle) or A+V di splays. 6. W 3 φ 4W = W R(L1) + W S(L2) W T(L3) KVA K W KVAR WW W 34 2 34 2 34 φφ φ =+ PF K W KVA W W W 34 34 34 φ φ φ = 7. Set the rotary switch to another position to exit this mode and clear the stored data. NOTE 1. The "+" sign printed on meter must face the power ...

  • HP Extech 380976 - page 14

    380976 V3.2 4/11 14 Capacitance Me asurements 1. Fully discharge the capacitor under test before pro ceeding. 2. Insert the test leads into the input jacks. (Black to ‘COM’ and Red to ‘ ’). 3. Set the rotary switch to the ‘ ’ position. 4. Connect the red and black test leads to the capacitor. For Electrolytic (polarized) capacitor s, co ...

  • HP Extech 380976 - page 15

    380976 V3.2 4/11 15 Meter Control Keys HOLD - MX/MN Ke y Data Hold Function Press this key momentarily to put the meter into Data Hold mode ( HOLD will appear on the LCD). In this mode, the meter freezes the displayed reading. To e xit the Data Hold mode, press the key again (the HOLD icon will sw itch off). Note that the Data Hold mode is not avai ...

  • HP Extech 380976 - page 16

    380976 V3.2 4/11 16 Automatic Sleep Mode and Battery Replacement The Meter is powered by a 9V batt ery. An AUTO SLEEP feature is included to preserve battery life. Note: The Auto Power OFF feature is disabled when the meter is in the MIN/MAX m ode Note: In the sleep mode the met er continues to draw a small amount of battery curr ent. Always turn t ...

  • HP Extech 380976 - page 17

    380976 V3.2 4/11 17 Specifications General Specifi cations Display Dual Display; 4-digit, 10,000 count (0 to 9999) LC D Jaw Opening 1.6” (42mm) Max. Input limit Max. voltage between any terminal and ground : 600Vrms Sampling rate 2.5 times per second (Digital Disp lay); Once every 6 seconds (KW, KVA, and KVAR) Auto Sleep After approx. 30 minutes ...

  • HP Extech 380976 - page 18

    380976 V3.2 4/11 18 Measurement Specific ations Accuracy: ± ( % of rdg + number of digits) from 18 o C to 28 o C (64 o F t o 82 o F) R.H. < 80% AC Current (50 Hz to 400Hz) Tr ue RMS Range Resolution Accuracy (% reading) Sensitivity Overload Protection 99.99A 10mA 0.10A 999.9A 100mA ± ( 2% + 20d) (50, 60Hz) ± (4 % + 20d) (40~400Hz) 1.0A 1000A ...

  • HP Extech 380976 - page 19

    380976 V3.2 4/11 19 M Ω (Resistance) Range Resolution Accuracy Overload Protection 9.999M Ω 1K Ω 99.99M Ω 10K Ω ±(5% + 10 d) 600V Capacitance Range Resolution Accuracy Overload Protection 10.000 μ F 1nF 100.00 μ F 10nF 1000.0 μ F 100nF ±(1.5% + 5 d) 7000 μ F 1 μ F ±(4.5% + 15 d) 600V Diode (Continuity <40mV) Range Resolution Accurac ...

  • HP Extech 380976 - page 20

    380976 V3.2 4/11 20  Support line (781) 890-7440 Technical support: Ex tension 200; E-mail: supp ort@extech.com Repair & Returns: Ex tension 21 0; E-mail: repair@extech.com Product specifications subject to change without notice For the late st version of thi s User Guide, Software updates, and other up-to-the-minute pr oduct information, ...

Fabbricante HP Categoria Power Supply

I documenti che otteniamo dal fabbricante del dispositivoHP Extech 380976 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici HP
- manuali per l’uso Extech 380976
- schede prodotto HP
- opuscoli
- o etichette energetiche HP Extech 380976
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso HP Extech 380976.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione HP Extech 380976, manuali di manutenzione, brevi manuali o manuali utente HP Extech 380976. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto HP Extech 380976.

Manuali per l’uso simili

Manuale completo del dispositivo HP Extech 380976, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare HP Extech 380976 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti HP Extech 380976.

Il manuale per l’uso completo HP, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale HP Extech 380976 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice HP Extech 380976, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per HP Extech 380976 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo HP Extech 380976 - che ci dovrebbe aiutare nei primi passi durante l'uso HP Extech 380976
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del HP Extech 380976
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio HP Extech 380976 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su HP Extech 380976?

Utilizza il modulo sottostante

Se non hai risolto il problema con HP Extech 380976 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con HP Extech 380976 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)