    DS-102 Dual Channel RS-232 Asynchronous Communications Adapter for ISA compatible machines User's Manual QUATECH, INC. TEL: (330) 434-3154 662 Wolf Ledges Parkway FAX: (330) 434-1409 Akron, Ohio 44311 BBS: (330) 434-2481 INTERFACE CARDS FOR IBM PC/AT AND PS/2 ...

  • Quatech DS-102 - page 2

    ...

  • Quatech DS-102 - page 3

    28 VIII. TROUBLESHOOTING 27 VII. SPECIFICATIONS 25 BAUD RATE SELECTION 24 FIFO polled mode operation (16550 UART only) 23 FIFO INTERRUPT MODE OPERATION (16550 UART only) 22 SCRATCHPAD REGISTER 22 MODEM STATUS REGISTER 21 LINE STATUS REGISTER 20 MODEM CONTROL REGISTER 19 LINE CONTROL REGISTER 18 FIFO CONTROL REGISTER (16550 only) 16 INTERRUPT IDENTI ...

  • Quatech DS-102 - page 4

    ...

  • Quatech DS-102 - page 5

    WARRANTY INFORMATION Quatech, Inc. warrants the DS-102 to be free of defects for one (1) year from the date of purchase. Quatech, Inc. will repair or replace any board that fails to perform under normal operating conditions and in accordance with the procedures outlined in this document during the warranty period. Any damage that results from impro ...

  • Quatech DS-102 - page 6

    © 1993, Quatech, Inc. NOTICE The information contained in this document cannot be reproduced in any form without the written consent of Quatech, Inc. Likewise, any software programs that might accompany this document can be used only in accordance with any license agreement(s) between the purchaser and Quatech, Inc. Quatech, Inc. reserves the righ ...

  • Quatech DS-102 - page 7

    I . GENERAL INFORMATION The Quatech, Inc. DS-102 provides two RS-232 asynchronous serial communication interfaces for IBM-compatible personal computer systems using the ISA (Industry Standard Architecture) expansion bus. The DS-102's two serial ports are implemented using 16450 Universal Asynchronous Receiver/Transmitters (UARTs). For higher p ...

  • Quatech DS-102 - page 8

    II . INSTALLATION If the default address and interrupt settings are sufficient, the DS-102 can be quickly installed and put to use. The factory defaults are listed in Figure 1 . YES 3 2F8 hex (COM2) Serial 2 YES 4 3F8 hex (COM1) Serial 1 ENABLED ? IRQ ADDRESS PORT Figure 1 --- Default address and IRQ settings for DS-102 The serial port outputs on t ...

  • Quatech DS-102 - page 9

    IRQ2 IRQ3 IRQ4 IRQ5 IRQ6 IRQ7 Set IRQ levels here (Diagram not to scale) 16450/16550 16450/16550 SW1 Serial 1 SW2 Serial 2 J4 Set addresses here (SW1, SW2) (J5, J6) J7 J8 J1 Serial 1 Serial 2 CN1 CN2 J5 J6 Serial 1 Serial 2 J2 J3 QUATECH INC. DS-102 Figure 2 --- Diagram of DS-102 Quatech DS-102 User's Manual 3 ...

  • Quatech DS-102 - page 10

    III . ENABLING AND ADDRESSING PORTS Setting the address Each serial port on the DS-102 uses 8 consecutive I/O locations in the range of 0000 hex to 07FF hex. The base address of each port is set using a DIP switch pack on the DS-102. When setting the address selection switches, a switch in the "ON" position specifies that the correspondin ...

  • Quatech DS-102 - page 11

    Switch on bit = 0 Switch off bit = 1 Serial 1 uses SW1 Serial 2 uses SW2 Factory default setting for Serial 1 --- 03F8 hex (COM1) ON 1234567 8 8 2 1 F 4 8 8 2 1 3 0 SW1 Factory default setting for Serial 2 --- 02F8 hex (COM2) ON 123456 78 8 2 1 F 4 8 8 2 0 2 0 SW2 Example: 03E8 hex (typical for COM3) ON 1234567 8 8 2 0 E 4 8 8 2 1 3 0 Example: 02E8 ...

  • Quatech DS-102 - page 12

    The standard addresses for serial ports COM1 and COM2 are listed in Figure 5 . Recommended addresses for serial ports COM3 and COM4 are also listed. The switch settings for these addresses are shown in Figure 4 . 02E8 hex COM4 Recommendations only. No official standards exist for COM3 and COM4. 03E8 hex COM3 Factory default for Serial 2. 02F8 hex C ...

  • Quatech DS-102 - page 13

    (This page intentionally left blank.) Quatech DS-102 User's Manual 7 ...

  • Quatech DS-102 - page 14

    IV . SETTING INTERRUPT LEVELS ( IRQ S) The DS-102 interrupt circuitry allows each port to use any interrupt level in the range IRQ2 through IRQ7. The interrupt levels are selected using jumper packs J5 for Serial 1 and J6 for Serial 2. In Figure 7 , the factory default settings for Serial 1 and Serial 2 are shown. IRQ7 IRQ2 IRQ3 IRQ4 IRQ5 IRQ6 Seri ...

  • Quatech DS-102 - page 15

    Interrupt Sharing An interrupt sharing circuit allows a port on the DS-102 to share an interrupt with the other port on the board or with another Quatech adapter supporting sharable interrupts. When interrupt sharing is used, the software must query each port attached to a given IRQ level when an interrupt for that IRQ is received by the computer. ...

  • Quatech DS-102 - page 16

    V . EXTERNAL CONNECTIONS RS-232-C devices are classified by their function as either Data Terminal Equipment (DTE) or Data Communication Equipment (DCE). Generally, data terminal equipment is defined as the communication source and data communication equipment is defined as the device that provides a communication channel between two DTE-type devic ...

  • Quatech DS-102 - page 17

    To simplify connections to other devices, each port on the DS-102 is equipped with a jumper block that allows the port to be configured as either a DTE- or DCE-type device. This allows the DS-102 to communicate with either DTE- or DCE-type devices without using a null modem cable. J7 is used for Serial 1 and J8 is used for Serial 2. The DTE/DCE sel ...

  • Quatech DS-102 - page 18

    The DS-102 connects to peripheral equipment through male D-9 connectors. Adapters are available to convert these connectors into standard D-25 male connectors. The standard serial port connections are listed in Figure 13 . 22 9 22 9 Ring Indicator (RI) 4 7 5 8 Clear To Send (CTS) 5 8 4 7 Request To Send (RTS) 20 4 6 6 Data Set Ready (DSR) 7 5 7 5 S ...

  • Quatech DS-102 - page 19

    (This page intentionally left blank.) Quatech DS-102 User's Manual 13 ...

  • Quatech DS-102 - page 20

    VI . SERIAL PORT FUNCTIONAL DESCRIPTION This section contains information intended for advanced users planning to do custom programming with the DS-102. The information presented here is a technical description of the interface to the 16450 or 16550 UART. The 16450 UART is an improved functional equivalent of the 8250 UART, performing serial-to-par ...

  • Quatech DS-102 - page 21

    Accessing the Serial Port registers Figure 15 lists the address map for the 16450 and 16550 UARTs. Each register can be accessed by reading from or writing to the proper I/O address. This I/O address is determined by adding an offset to the base address set for the particular serial port. The base address is set using DIP switches on the DS-102 (se ...

  • Quatech DS-102 - page 22

    INTERRUPT ENABLE REGISTER This register is located at I/O address [base+1]. It enables the five types of UART interrupts. Interrupts can be totally disabled by setting all of the enable bits in this register to a logic 0. Setting any bit to a logic 1 enables that particular interrupt. ETBEI --- Received Data Available Interrupt: When set (logic 1), ...

  • Quatech DS-102 - page 23

    IP --- Interrupt pending: When logic 0, indicates that an interrupt is pending and the contents of the interrupt identification register may be used to determine the interrupt source. See Figure 18 . 0 IID0 --- 1 IID1 --- 2 Interrupt Identification: Indicates highest priority interrupt pending if any. See Figure 18 . NOTE: IID2 is always a logic 0 ...

  • Quatech DS-102 - page 24

    FIFO CONTROL REGISTER (16550 only) This register, which applies only to the 16550 UART, is a write-only register located at I/O address [base+2]. It is used to enable the FIFO mode, clear the FIFOs, set the threshold level for the receive FIFO to generate interrupts, and to set the mode under which the device uses DMA. Note that DMA mode is NOT sup ...

  • Quatech DS-102 - page 25

    LINE CONTROL REGISTER This register is located at I/O address [base+3]. It is used for specifying the format of the asynchronous serial data to be processed by the UART, and to set the Divisor Latch Access Bit (DLAB) allowing access to the baud rate divisor latches. WLS0 --- 0 Word length select: Determines the number of bits per transmitted word. ...

  • Quatech DS-102 - page 26

    MODEM CONTROL REGISTER This register is located at I/O address [base+4], and is used to control the interface with the modem or device used in place of a modem. This register allows the states of the "modem control signals" to be changed. These are DTR (Data Terminal Ready) and RTS (Request To Send). It is also possible to place the UART ...

  • Quatech DS-102 - page 27

    LINE STATUS REGISTER This register is located at I/O address [base+5]. It is used to provide various types of status information concerning the data transfer. As Figure 22 shows, the Line Status Register indicates several types of errors, an empty transmit buffer, a ready receive buffer, or a break on the receive line. DR --- Data ready: Indicates ...

  • Quatech DS-102 - page 28

    MODEM STATUS REGISTER This register is located at I/O address [base+6]. It reports on the status of signals coming from the modem or equipment used in place of a modem. It allows the current states of "modem control signals" to be sensed. These signals include the DCD (Data Carrier Detect), RI (Ring Indicator), DSR (Data Set Ready), and C ...

  • Quatech DS-102 - page 29

    FIFO INTERRUPT MODE OPERATION (16550 UART only) When the receiver FIFO and receiver interrupts are enabled: 1 . The receive data interrupt is issued when the receive FIFO reaches the trigger level. The interrupt is cleared as soon as the receive FIFO falls below the trigger level. 2 . The Interrupt Identification Register's receive data availa ...

  • Quatech DS-102 - page 30

    FIFO polled mode operation (16550 UART only) The receiver and transmitter are operated independently, which would allow either or both to be used in a polled mode rather than using interrupts to determine when the UART needs to be serviced. To use the UART in a polled mode, the software is responsible for continuously checking for the conditions th ...

  • Quatech DS-102 - page 31

    BAUD RATE SELECTION The 16450 or 16550 UART determines the baud rate of the serial output using a combination of the clock input frequency and the value written to the divisor latches. Standard personal computer serial interfaces use an input clock of 1.8432 MHz. To increase versatility, the DS-102 uses an 18.432 MHz crystal and a frequency divider ...

  • Quatech DS-102 - page 32

    2.86 2 56000 - 3 38400 - 6 19200 - 12 9600 - 16 7200 - 24 4800 - 32 3600 - 48 2400 0.69 58 2000 - 64 1800 - 96 1200 - 192 600 - 384 300 - 768 150 0.026 1047 110 - 1536 75 - 2304 50 ERROR BETWEEN DESIRED AND ACTUAL VALUES (%) DIVISOR LATCH VALUE DESIRED BAUD RATE Figure 25 --- Divisor Latch settings for common baud rates using 1.8432 MHz input clock ...

  • Quatech DS-102 - page 33

    VII . SPECIFICATIONS Bus interface: Industry Standard Architecture (ISA) 8-bit bus Serial ports Controller: 16450 (16550 optional) Interface: Two male D-9 connectors Two male D-25 connectors optional using adapter cables Transmit drivers: MC1488 or compatible High level output voltage: +9V min, +10.5V max Low level output voltage: -9V min, -10.5V m ...

  • Quatech DS-102 - page 34

    VIII . TROUBLESHOOTING Listed here are some common problems and frequent causes of those problems. Suggestions for corrective action are given. If the information here does not provide a solution, contact Quatech Customer Service for technical support. Any unauthorized repairs or modifications will void the DS-102's warranty. Computer will not ...

  • Quatech DS-102 - page 35

    DS-102 Dual Channel RS-232 Asynchronous Communications Adapter User's Manual Revision 3.00 August 13, 1993 ...

Fabbricante Quatech Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoQuatech DS-102 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Quatech
- manuali per l’uso DS-102
- schede prodotto Quatech
- opuscoli
- o etichette energetiche Quatech DS-102
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Quatech DS-102.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Quatech DS-102, manuali di manutenzione, brevi manuali o manuali utente Quatech DS-102. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Quatech DS-102.

Manuali per l’uso simili

Manuale completo del dispositivo Quatech DS-102, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Quatech DS-102 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Quatech DS-102.

Il manuale per l’uso completo Quatech, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Quatech DS-102 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Quatech DS-102, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Quatech DS-102 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Quatech DS-102 - che ci dovrebbe aiutare nei primi passi durante l'uso Quatech DS-102
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Quatech DS-102
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Quatech DS-102 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Quatech DS-102?

Utilizza il modulo sottostante

Se non hai risolto il problema con Quatech DS-102 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Quatech DS-102 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)