    381333–201 G 50 Hanove r Road, F lorham Park, New J ersey 07932–1591 USA For sales or service call 1 800 800–2726 (A SCO ) www.ascopower .com AS CO PO WER TECH NO LOGI E S CA NA DA PO Box 1238, 17 Airport R oad, Brantf ord, O ntario, Can ada N 3T 5T3 Operator’s Manual Seri es 300 Automatic T ransfer S witc hes H–d esi gn , 600 th rou gh 1 ...

  • Emerson 300 - page 2

    Namepl ate The T rans fer Switch nam epla te incl udes data for each sp ecific A SCO S eries 300 A TS. Use th e A TS only wit hin the limits show n on this namep late. Ca talog Num ber Identif icatio n A typ ica l C ata l og Numbe r i s s hown be lo w wi th i ts elements ex plained . The ex ample is fo r a Series 300 A T Sw i t hs w i t c h e dn e ...

  • Emerson 300 - page 3

    terminal bl ock TB for engine start and switch posi tion co ntacts Tr a n s f e r Switch Con tr oller power connectio ns power connectio ns membrane control s 800 and 1000 a mp er e siz es i n typ ical enclo sur e wit h locat ion o f cus tom er co nnectio ns neutral connectio ns neutral connectio ns ...

  • Emerson 300 - page 4

    terminal bl ock TB for engine start and switch posi tion co ntacts Tr a n s f e r Switch Con tr oller power connectio ns power connectio ns membrane control s 1200 amp ere s ize in t ypi cal enclos ure wit h locati on of cus tom er co nnections neutral connectio ns neutral connectio ns ...

  • Emerson 300 - page 5

    SECT ION 1 INST ALLA TION 1 --- 1 Series 300 A utomatic T ransfer Sw itches are fac tory wired an d tested. Instal lation r equires skid r emoval then sec urin g the enc los ure to the s uppor ting foundation. Remove th e Shipping S kid Open the fr ont door and rem ove the four l ag sc rews ( 2 in front, 2 i n rear) securing enc losure to the wood ...

  • Emerson 300 - page 6

    ter min al b lock f or e ngin e s ta rt a nd auxiliary ci rcuit connections left s id e of transfer switch COMMON FEA TU RE 7 closes to start FEA TU RE 8 open s to star t COMMON FEA TU RE 14B closed on em ergenc y FEA TU RE 14A clos ed on nor mal COMMON FEA TU RE 14BA closed on em ergenc y FEA TU RE 14AA clos ed on nor mal Engi ne Sta rti ng Sig na ...

  • Emerson 300 - page 7

    INST ALLA TION (cont inued) 1 --- 3 F unctio nal T est The F unctional T est consists of thr ee chec ks: manual operation, v oltage chec ks, and el ectrical operation. NOT ICE Do these checks in the order presented to avoid damaging the auto matic transfer s witch. R ead all instructions on the W iring Diagram and labels affixed to the autom atic t ...

  • Emerson 300 - page 8

    INST ALLA TION (cont inued) 1 --- 4 observe these l ights Figure 1–5. St andard contro ls and indicato rs. 2–V o l t a g eC h e c k s First check nameplate on tra nsfer swi tch; rated voltage m u s tb et h es a m ea sn o r m a la n de m e r g e n c yl i n e voltages. Use ext reme caution when using a meter to measure volta ges in the fo llowing ...

  • Emerson 300 - page 9

    INST ALLA TION (cont inued) 1 --- 5 p r e s st h i sb u t t o n observe these l ights Figure 1–6. Standard contro ls and indic ators. 3 – Electrica l Opera tion Th i s pr oce du re wi ll che ck t he e le ctr ica l o pe rt i on o f t he A utomatic T ransfe r Switch. See Figure 1–6. Close th e transfe r switc h encl osure door a nd tighten t he ...

  • Emerson 300 - page 10

    Hol d 15 sec .t o start t he engine generator and to transf er the load to emergency . Press to cancel the active exercise period (sto ps engine now or afte r cooldow n) Se e page 5– 1. Hol d 5 sec .t os e t 20 min. engine ex ercise perio d immediately (engine starts) and weekly thereaf ter . ³ blinks sl owly when button is r eleased (set) and d ...

  • Emerson 300 - page 11

    SECT ION 3 TEST ING & SERVIC E 3 --- 1 PREV ENTIV E MAIN TENAN CE F or high rel iabil ity and long l ife for the A TS: Ope rate t he sw itc h at l east o nce a mo nth .P e r f o r m t h i s 4–step Electrical Operat ion T e st (te st with load t ransfer). T r ansfer Swi tch T est 1. Press and ho ld the door -mounted T ra nsfer T est button unt ...

  • Emerson 300 - page 12

    TEST ING & SERVIC E (continued) 3 --- 2 MANUAL L OAD TR ANSFER This pr oced ure w ill m anual ly tr ansfer th e load if th e cont ro lle r is d i sco nne ct ed . Do no t manually operate the transfer switch until bot h power so urces are disconnected: open bot h circuit breakers . 1. Open normal and emergency source ci rcuit brea kers. 2. Use t ...

  • Emerson 300 - page 13

    SECT ION 4 ADJUST MENTS 4 --- 1 Ti me De l a y Ad j u st m e n t Standard ti me delays are set to customer specificati ons (if none specif ied, st andard factory set tings are used). T o change a setting, follow proc edure on page 4-2. Use T abl e 4-1 as a gu ide to time del ay values and their c or- responding adjustment DIP switch or potentiomete ...

  • Emerson 300 - page 14

    ADJUST MENTS (continued) 4 --- 2 NOT ICE Do not make any set ting changes while the contro ller is energized. How to Change a Setti ng 1. Prev ent the transfer switch from operating b y discon- nec ting one s ourc e first, then the o ther, as fol low s: a. If the transfer s witch is in the No rmal p osition, ope n t he e mer gen cy so urce ci r cui ...

  • Emerson 300 - page 15

    SECTION 5 CONTROL FEA TURES – ENGINE EXER CISERS 5 --- 1 These timer s periodic ally exer cise the em ergenc y engine-g enerator p lant. They can be s et to exercise w ith or withou t load tr ansfer, or they can b e compl etely disab led. The engine-gen erator shoul d be exercised u nder load on ce a week for a minimum time period of 20 minutes, ...

  • Emerson 300 - page 16

    CONTRO L F EATURES (continued) 5 --- 2 Opt ion al Ac ce ssory 11BG – SOURCE A VAILABILITY SIG NAL & P ROGRAMMA BLE EN GINE EX ERCIS ER MOD ULE 2–line display 3 buttons connectio ns for source ava ila bilit y signal co ntacts Figure 5–2. Accessory 11B G module ( mounted behind operato r interface and connected to the co ntroll er) incl ude ...

  • Emerson 300 - page 17

    Fa s t/ Sl o w A d j u st Dayl ight Savi ng Time A dju st Date Time Start T Ime Engine Exerciser Run TIm e CONTRO L F EATURES (continued) 5 --- 3 How to Set Option a l Progra mm ab le En gin e Exe rcis er (p art o f Acc. 11BG m od ule) Haza rdous vol tage ca pabl e of causin g shock, burns, o r death is used in this t ransfer switch. Deenergize bo ...

  • Emerson 300 - page 18

    CONTRO L F EATURES (continued) 5 --- 4 INPHASE M ONITOR FOR M OTOR LOAD TR ANSF ER Inphase monitori ng logic con trols tr ansfer and retransfe r of motor loads, so that inrush current s do not exceed normal starti ng currents. It a voids nuisance tripping of cir cuit breakers and m echanic al damag e to mot or co up li ngs . The Motor Load T ransfe ...

  • Emerson 300 - page 19

    CONTRO L F EATURES (continued) 5 --- 5 OPTIONAL STR IP HEA T ER (Accessor y 44) A cc essory 44 Str ip Heater is design ed to keep ambient temp eratures within the A utomatic T ransfer Switc h en closu re a t a ccep ta ble le ve ls. Thi s a cces sor y con si st s of a mounting bra cket with strip heat er, thermosta t, and terminal block. A transform ...

  • Emerson 300 - page 20

    INDEX Printed in U .S.A. Copy right - - - ASC O Power T echn ologies, L.P . 2011 A accessories, 5–2, 5–5 auxil iary cir cuits , 1–2 B battery , 4–2, 5–1 buttons, push, 3–1 bypass time delay, 1–5, 2–1, 3–1 C cable lugs, 1–1 prepar ation, 1–1 cat alo g nu mber, in si de co ve r cleaning, 3–1 connections engine control contact, ...

Fabbricante Emerson Categoria Power Supply

I documenti che otteniamo dal fabbricante del dispositivoEmerson 300 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Emerson
- manuali per l’uso 300
- schede prodotto Emerson
- opuscoli
- o etichette energetiche Emerson 300
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Emerson 300.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Emerson 300, manuali di manutenzione, brevi manuali o manuali utente Emerson 300. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Emerson 300.

Manuali per l’uso simili

Manuale completo del dispositivo Emerson 300, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Emerson 300 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Emerson 300.

Il manuale per l’uso completo Emerson, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Emerson 300 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Emerson 300, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Emerson 300 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Emerson 300 - che ci dovrebbe aiutare nei primi passi durante l'uso Emerson 300
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Emerson 300
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Emerson 300 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Emerson 300?

Utilizza il modulo sottostante

Se non hai risolto il problema con Emerson 300 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Emerson 300 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)