  • Giant P200A-3100/5100 - page 1

    Contents: Installation Instructions: page 2 Pump Specifications: pages 3-7 Parts List / Kits: page 8 Torque Specifications: page 8 Exploded View: page 9 Repair Instructions: page 10-11 Warranty Information: back page Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Seri e s P 200 A-3100/5100 Updated 3/98 Stainless Stee ...

  • Giant P200A-3100/5100 - page 2

    INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsa- tion. Dampeners can also reduce the severity of pres ...

  • Giant P200A-3100/5100 - page 3

    P217A-3100/5100 HORSEPOWER REQUIREMENTS RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 1725 1.7 0.9 1.4 1.7 2.0 2.3 3000 3.0 1.7 2.5 3.1 3.5 4.1 3200 3.2 1.8 2.6 3.3 3.8 4.4 3450 3.4 1.9 2.8 3.5 4.0 4.7 Specifications Model P217A-3100/5100 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the va ...

  • Giant P200A-3100/5100 - page 4

    P218A-3100/5100 HORSEPOWER REQUIREMENTS RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 1150 2.1 1.2 1.7 2.2 2.5 2.9 1450 2.6 1.5 2.2 2.7 3.1 3.6 1750 3.4 1.9 2.8 3.5 4.0 4.7 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees t ...

  • Giant P200A-3100/5100 - page 5

    V olume ....................................................................................................... Up to 4.2 GPM Discharge Pressure ..................................................................................... Up to 2000 PSI Inlet Pressure ......................................................................................... ...

  • Giant P200A-3100/5100 - page 6

    Specifications Model P220A-3100/5100 V olume ....................................................................................................... Up to 4.7GPM Discharge Pressure ..................................................................................... Up to 2000 PSI Inlet Pressure ..................................................... ...

  • Giant P200A-3100/5100 - page 7

    Specifications Model P221A-3100 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Ex ...

  • Giant P200A-3100/5100 - page 8

    ITE M PART NO. DESCRIPTION QTY. 1 08300 Crankcase 1 2 08301 Dipstick (Except P217, black ) 1 2 08480 Dipstick (P217, red ) 1 3 08302 Crankcase Plug Cover 1 3A 07190 Drain Plug & Gasket 1 4 08005 O-Ring 1 5 08185 Oil Drain Plug 1 6 07188-0100 Screw, 316 S.S. 4 6A 07223-0100 Spring Washer, 316 S.S. 7 08303 Bearing Cover I 2 8 08490 Sight Glass 1 ...

  • Giant P200A-3100/5100 - page 9

    Exploded View - P200A-3100/5100 Series Unique for P221- 3100 or ...

  • Giant P200A-3100/5100 - page 10

    REPAIR INSTRUCTION - P200A-3100/5100 SERIES Disassembly sequence of fluid end of P200A-3100/5100 series pump Note: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elas- tomers) from cutting and scor ...

  • Giant P200A-3100/5100 - page 11

    Disassembly sequence of the back end of the P200A-3100/5100 series pump. 1 ) Before you begin, drain the oil from the crankcase. 2) Remove the crankcase cover (3) and o-ring (4) from the crankcase (1). To remove the crankshaft (13), remove the bearing cover (7) and sight glass (8). Using a rubber mallet, remove the crankshaft axially through the co ...

  • Giant P200A-3100/5100 - page 12

    GIANT INDUSTRIES, INC. , 900 N. Westwood Ave., P.O. Box 3187, Toledo, Ohio 43607 PHONE (419) 531-4600, FAX (419) 531-6836, www.giantpumps.com  Copyright 1998 Giant Industries, Inc. P200A-3100/5100 DIMENSIONS (mm) 3/98 P200A-3100.PM6 GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer t ...

Fabbricante Giant Categoria Plumbing Product

I documenti che otteniamo dal fabbricante del dispositivoGiant P200A-3100/5100 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Giant
- manuali per l’uso P200A-3100/5100
- schede prodotto Giant
- opuscoli
- o etichette energetiche Giant P200A-3100/5100
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Giant P200A-3100/5100.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Giant P200A-3100/5100, manuali di manutenzione, brevi manuali o manuali utente Giant P200A-3100/5100. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Giant P200A-3100/5100.

Manuali per l’uso simili

Manuale completo del dispositivo Giant P200A-3100/5100, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Giant P200A-3100/5100 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Giant P200A-3100/5100.

Il manuale per l’uso completo Giant, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Giant P200A-3100/5100 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Giant P200A-3100/5100, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Giant P200A-3100/5100 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Giant P200A-3100/5100 - che ci dovrebbe aiutare nei primi passi durante l'uso Giant P200A-3100/5100
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Giant P200A-3100/5100
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Giant P200A-3100/5100 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Giant P200A-3100/5100?

Utilizza il modulo sottostante

Se non hai risolto il problema con Giant P200A-3100/5100 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Giant P200A-3100/5100 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)