Manuale per l’uso Linear AE2000PLUS

24 pagine 1.15 mb
Scarica

Vai alla pagina of 24

Summary
  • Linear AE2000PLUS - page 1

    USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - T oll Free FAX (800) 468-1340 www .linearcorp.com AE2000Plus T elephone Entr y & Access Control System PRINTER’S INSTRUCTIONS: INSTR,INSTL,AE2000Plus - LINEAR P/N: 227541 B - INK: BLACK - MA TERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM ...

  • Linear AE2000PLUS - page 2

    2 Contents Introduction The Model AE2000Plus T elephone Entr y & Access Control System is designed for use as a primary access control device f or gated communities, parking garages, offi ce b uildings, apartments, dor mitories, hotels/motels, commercial b uildings and recreational facilities. Housed in a lock ed, rugged stainless steel faced ...

  • Linear AE2000PLUS - page 3

    3 Har dwar e F eatur es ✓ BUILT -IN RADIO RECEIVER Variable gain, high-sensitivity receiver for wireless transmitters ✓ FOUR FORM “C” (N.O. & N.C) RELAYS Each relay has 3-amp @ 24-volt rating ✓ FOUR REQUEST-TO-EXIT INPUTS Activates access device for exiting using a hardwired switch ✓ FOUR SENSING INPUTS For sensing door position to ...

  • Linear AE2000PLUS - page 4

    4 Accessor y Over view PBUS Accessories Sev eral compatib le accessories are availab le to connect to the three 6-wire communications “PBUS” inputs. Up to six PBUS accessor ies can be used with each AE2000Plus unit. AM-RRR R emote Radio R ecei ver For wireless tr ansmitters, connect the Model AM-RRR high-gain superheterodyne UHF receiver . The ...

  • Linear AE2000PLUS - page 5

    5 Component Locations OPTIONAL CAME R A DI S PLAY LEFT CA B INET LOCK OPTIONAL PO S TAL LOCK S PEAKE R KEYPAD MIC R OPHONE R ELAY TE R MINAL S WIE G AND INPUT TE R MINAL S TAMPE R S WITCH R ECEIVE R R AN G E KNO B ANTENNA CONNECTO R MIC R OPHONE PO S TAL LOCK MOUNTIN G PLATE S PEAKE R P R OMPT S PEECH VOLUME ADJU S TMENT CPU/INTE R FACE CONNECTO R ...

  • Linear AE2000PLUS - page 6

    6 Wiring Diagram AE2000PLUS THIS WIRING EXAMPLE SHOWS: DOOR ACCESS WITH A DOOR STRIKE ON RELAY CHANNEL "A" DOOR ACCESS WITH A MAGNETIC LOCK ON RELAY CHANNEL "B" GATE ACCESS WITH A GATE OPERA TOR ON RELAY CHANNEL "C" (YOUR INSTALLATION MAY VARY) G ND DAT 0 DAT 1 LED1 HOLD PW R LED 2 G ND DAT 0 DAT 1 LED1 HOLD PW R LED 2 ...

  • Linear AE2000PLUS - page 7

    7 Impor tant Mounting Requir ements The AE2000Plus T elephone Entr y System can be installed for pub lic or private use. The mounting requirements will vary depending on the installation. Review the f ollowing inf ormation before beginning the installation. Mounting Environment Consider the environmental f actors at the desired mounting location. T ...

  • Linear AE2000PLUS - page 8

    8 Entr y Sys tem Mounting The AE2000Plus cabinet is designed to be mounted three wa ys: • The unit can be mounted directly to a wall or fl at surf ace. • The unit can be mounted recessed into the wall. • The unit can be mounted on a standard gooseneck pedestal. Choose a well lit location near the controlled opening. Wiring access f or power ...

  • Linear AE2000PLUS - page 9

    9 Entr y Sys tem Mounting (Continued) Recessed Mounting The cabinet can be mounted recessed using the accessor y trim-ring (P/N ACP00914). The trim-ring mounts in the wall and the cabinet attaches to the trim-ring. 1. Identify the location of any studs in the wall. 2. Cut a 15-½” wide by 19” high rectangular hole between studs at the mounting ...

  • Linear AE2000PLUS - page 10

    10 Rela y Output Wiring Any of the f our relay outputs channels (A-D) can be used to control access devices on doors or gates . Door or Pedestrian Gate Control 1. Install a low v oltage electric door str ike or magnetic lock as a locking de vice for the door or pedestrian gate. 2. Install the power supply or tr ansformer for the loc king device. DO ...

  • Linear AE2000PLUS - page 11

    11 P ower, Bat ter y, & Gr ound Wiring Power Wiring ✦ NO TE: DO NO T APPL Y PO WE R UNTIL THE IN S T ALLA TION I S COMPLETE. TU R N MA S TE R PO WE R S WITCH OFF B EFO R E WI R IN G . 1. Route two wires between the AE2000Plus and the pow er transf or mer . • For po wer wire runs up to 75 feet, use 18 A WG, THHN 600-v olt insulated wire. • ...

  • Linear AE2000PLUS - page 12

    12 T elephone Wiring For telephone entry and programming, the AE2000Plus connects to a standard telephone line. Impor tant T elephone Wiring Tips • DO NO T ROUTE TELEPHONE AND AC WIRIN G INSIDE THE SAME CONDUIT . Route all telephone wires inside a dedicated conduit that is at least six inches aw ay from any A C line wiring. • All telephone wiri ...

  • Linear AE2000PLUS - page 13

    13 Optional Color CC T V Camera Linear’ s Model CCM-1 (P/N A CP00904) CCTV camera can be installed inside the AE2000Plus Entr y System. The camera pro vides a video signal for vie wing the area in front of the entry system. The CAMERA connector is used to connect the camera to the AE2000Plus. The 4-conductor cable routes power to , and video from ...

  • Linear AE2000PLUS - page 14

    14 PBUS Accessories Up to six accessories (keypads , proximity readers , remote receivers) can be connected to the three PBUS input/output por ts. A typical application for a remote k eypad would be to control a second door or gate . Linear’ s PBUS de vices compatible with the AE2000Plus are: • AM-RRR Remote Radio Receiver • AM-RGR Remote Rad ...

  • Linear AE2000PLUS - page 15

    15 Optional Net w ork Connections Linear’ s AE1000Plus, AE2000Plus, & AM3Plus Access Control Systems can be connected together in a network. A network will allow sharing programming and user inf ormation between the systems. Program each unit to a different netw ork Node Address (see Page 19). ✦ IMPORT ANT COMP A TIBILITY NO TE: Linear’ s ...

  • Linear AE2000PLUS - page 16

    16 Optional Net w ork Connections (Continued) Network Confi guration for AccessBase2000 Programming If the system is going to be programmed using Linear’ s AccessBase2000 software, units comm unicate with each other on the network through RS-485 cable connections . AccessBase2000 does not suppor t unit-to-unit network communications through mode ...

  • Linear AE2000PLUS - page 17

    17 NET-A G ND NET- B NETWO R K UNIT " 3 " NET-A G ND NET- B NETWO R K UNIT "4" NET-A G ND NET- B NETWO R K MA S TE R UNIT "1" NET-A G ND NET- B NETWO R K UNIT "2" ACCE SS CONT R OL HOME R UN NETWO R K U S ING ONE UNIT A S A NETWO R K MA S TE R NOTE : GROUND CABLE SHIELDS ONLY AT ONE END S HIELD S HIELD S HIEL ...

  • Linear AE2000PLUS - page 18

    18 Sys tem A d jus tments The factory settings are suffi cient f or most installations. The system can be adjusted to customize the installation. System V olume Adjustment The sound lev el of the synthesized voice and ke y beep can be adjusted. 1. Locate the SYSTEM V OLUME adjustment on the CPU circuit board. 2. Press ke ys on the keypad while adj ...

  • Linear AE2000PLUS - page 19

    19 Internal Contr ols On-board Pushbuttons Sev en pushbuttons are on the main circuit board. Refer to the fi gure for the location of each pushbutton. • UP button adds one to the value on the ST A TUS/PROGRAM displa y . • DOWN b utton subtracts one from value on the ST A TUS/PROGRAM displa y . Press with the UP button f or one second to enter ...

  • Linear AE2000PLUS - page 20

    20 AE2000Plus Operation Resident Access with an Entr y Code • Residents hav e up to 40 seconds to ke y in their entr y code. • Up to eight seconds are allow ed between each keystrok e. • If the code is entered wrong, press the ke y to reset the ke ypad and re-enter the correct entr y code. (On remote keypads, press the ke y to reset the keypa ...

  • Linear AE2000PLUS - page 21

    21 17-3/8" 21-1/8" 4" OPTIONAL TRIM RING 15-1/4" 19" 4" AE2000PLUS Dimension Drawing Specifi cations MECHANICAL Case dimensions: 15-1/4” W x 19” H x 4” D ELECTRICAL V oltage: 16-24 V olts AC or 12-24 V olts DC Current: 2000 mA @ 16 V AC maximum Backup Battery: Externally charged 12 V olt DC source, 6 amp/hr mini ...

  • Linear AE2000PLUS - page 22

    22 T r oubleshooting System completely dead 1. No power from tr ansformer . Check v oltage at transf or mer terminals. 2. Check v oltage at AE2000Plus power terminal strip. Buzz on speaker 1. Check f or 24 volt A C power shorted to wiring conduit. 2. Check f or telephone line shor ted to ground. 3. V erify that telephone wires are twisted pair. 4. ...

  • Linear AE2000PLUS - page 23

    23 Linear Limited W ar rant y This Linear product is warranted against def ects in material and workmanship for tw enty-four (24) months. This warranty e xtends only to wholesale customers who buy direct from Linear or through Linear’ s normal distr ibution channels. Linear does not warrant this product to consumers. Consumers should inquire from ...

  • Linear AE2000PLUS - page 24

    Copyright © 2008 Linear LLC 227541 B ...

Fabbricante Linear Categoria Automobile Alarm

I documenti che otteniamo dal fabbricante del dispositivoLinear AE2000PLUS possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Linear
- manuali per l’uso AE2000PLUS
- schede prodotto Linear
- opuscoli
- o etichette energetiche Linear AE2000PLUS
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Linear AE2000PLUS.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Linear AE2000PLUS, manuali di manutenzione, brevi manuali o manuali utente Linear AE2000PLUS. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Linear AE2000PLUS.

Manuali per l’uso simili

Manuale completo del dispositivo Linear AE2000PLUS, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Linear AE2000PLUS dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Linear AE2000PLUS.

Il manuale per l’uso completo Linear, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Linear AE2000PLUS - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Linear AE2000PLUS, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Linear AE2000PLUS che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Linear AE2000PLUS - che ci dovrebbe aiutare nei primi passi durante l'uso Linear AE2000PLUS
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Linear AE2000PLUS
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Linear AE2000PLUS in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Linear AE2000PLUS?

Utilizza il modulo sottostante

Se non hai risolto il problema con Linear AE2000PLUS con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Linear AE2000PLUS è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (1)

Виктор Аксенов

При команде ПЕЧАТЬ - в принтере закончилась бумага, хотя заложены листы. Пробовал закладывать по одному листу-тоже самое и потом выскакивает команда - Уровняйте картриджи. Действую по инструкции-все повторяется вновь. Посмотреть шестеренки - не пойму как разобрать. Логику команд я не знаю и от каких датчиков они поступают тоже Помогите: как разобрать и что посмотреть. Жалко выбрасывать,а за диагностику дерут - дешевле новый купить. Работал много лет прекрасно.