Manuale per l’uso Honeywell MS9540 Voyager

56 pagine Non applicabile
Scarica

Vai alla pagina of 56

Summary
  • Honeywell MS9540 Voyager - page 1

    METROLOGIC INSTRUMENTS, INC. MS9500 Voyager ® Series Single-Line Hand Held Laser Scanner Installation and User's Guide ...

  • Honeywell MS9540 Voyager - page 2

    Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any for m or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Cop yright Act of 1976. Trademarks Metrologic is a registered trademark ...

  • Honeywell MS9540 Voyager - page 3

    ii T ABLE OF C ONTENTS Introduction Product Overview ............................................................................................. 1 Scanner and Accessori es ................................................................................. 2 Scanner Comp onents ........................................................................ ...

  • Honeywell MS9540 Voyager - page 4

    ii T ABLE OF C ONTENTS IR Activati on Rang e ............................................................................................ 25 Applications an d Protoc ols ................................................................................. 26 Troubleshootin g Guid e ....................................................................... ...

  • Honeywell MS9540 Voyager - page 5

    1 I NTRODUCTION Product Overvie w Metrologic's MS9500 Voyager ® series of hand-held (single-line) l aser scanners offers the user an aggressive solution for sca nning all standard 1D bar codes including GS1 DataBar™ (RS S) bar codes. The MS9500 series is equipp ed with both in-stand and out-of-stand operation e nabling hand-hel d or fixed p ...

  • Honeywell MS9540 Voyager - page 6

    2 I NTRODUCTION Scanner and Accessories B ASI C K IT Part # Description MS9520 or MS9540 Voyager Bar Code Scanner or Voyager CG Bar Code Scanner with CodeGate 00-02544 MetroSelect Single-Line Confi guration Guide* 00-02410 MS9500 Voyager Series Sin gle-Line Hand Held Laser Scanner Installation and User’ s Guide* * Available for download on the Me ...

  • Honeywell MS9540 Voyager - page 7

    3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part # Description 53-53213 x -N-3 USB Full Speed Cable Locki ng Plus-Power™ Type A, Black, Coiled Cord with Long Strain Rel ief 53-53214 x -N-3 USB Full Speed Cable Locki ng Plus-Power™ Type A, Black, Coiled Cord with Lo ng Strain Relief, Extended Length Not for use with Low Speed ...

  • Honeywell MS9540 Voyager - page 8

    4 I NTRODUCTION Scanner Components No. Item Description 1 Green LED ♦ See Visual Indicators on page 18 2 Red LED ♦ See Visual Indicators on page 18 3 Yellow LED ♦♦ See Visual Indicators on page 18 4 Button ♦♦ See How to use CodeGate on page 12 5 Red Window Laser Aperture 6 Speaker See Audible Indica tors on page 17 7 Cable Release Pin-H ...

  • Honeywell MS9540 Voyager - page 9

    5 I NTRODUCTION Disconnecting the Po werLink Cable Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disco nnected from the PowerLink cable. Figure 2. 1. Locate the small ‘pin-hole’ o n the t op of the unit near the bottom of the Voyager logo. 2. Bend an ordi ...

  • Honeywell MS9540 Voyager - page 10

    6 I NTRODUCTION Labels Every scanner has labels and mold ed text located on the undersi de of the unit. The labels and text contain im portant information such as the unit’s d ate of manufacture, serial number, CE and cautio n information. F igure 5 provides examples of the labels and the molded text. Figure 5 . Molded Text and Label Examples Cau ...

  • Honeywell MS9540 Voyager - page 11

    7 I NSTALLING THE S CANNER TO THE H OST S YSTEM RS232, Laser Emulation, and Light Pen Emulation 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the scanner. There will be an au dible click when the connector lock engages. If the scanner is receiving power from the host system, skip to step #5. 3. Connect the ...

  • Honeywell MS9540 Voyager - page 12

    8 I NSTALLING THE S CANNER TO THE H OST S YSTEM RS485  1. Turn off the host system. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the scanner. You will hear a ‘click’ when the connection is made. 3. Connect the other end of the MVC cable to the host device. 4. Turn on the host system. Plugging the scanner into a ...

  • Honeywell MS9540 Voyager - page 13

    9 I NSTALLING THE S CANNER TO THE H OST S YSTEM Keyboard Wedge 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the scanner. You will hear a ‘click’ when the connection is made. If the scanner is receiving power from the host system, skip to step #5. 3. Connect the L-shaped plug of the power supply into th ...

  • Honeywell MS9540 Voyager - page 14

    10 I NSTALLING THE S CANNER TO THE H OST S YSTEM Stand-Alone Key board 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector into the jack on the scanner. You will hear a ‘click’ when the connection is made. If the scanner is receiving power from the host system, skip to step #5. 3. Connect the L-shaped plug of the power supply ...

  • Honeywell MS9540 Voyager - page 15

    11 Figure 10. I NSTALLING THE S CANNER TO THE H OST S YSTEM Integrated USB: Full Speed (-40) Low Speed (-38) 1. Turn off the host system. 2. Connect the 10-pin RJ45 male connector of the USB cable into the jack on the scanner. You will hear a ‘click’ when the connection is made. 3. Connect the other end of the USB cable to the host USB port. 4. ...

  • Honeywell MS9540 Voyager - page 16

    12 T HE MS9540 V OYAGER CG ® S ERIES How to Use CodeGate and the Man ual Activation Mode C ODE G ATE ® M ANUAL A CTIVATION M ODE * * This feature is not a default setting. Refer to the MetroSelect Configuration Guide for instructions on enabling the Manual Activation Mode. Figure 11. Figure 12. Three Modes of Operati on Auto Trigger, In-Stand • ...

  • Honeywell MS9540 Voyager - page 17

    13 S TAND K ITS Types Free Standing Kit #46-46128 ( Figure 13 ) Kit Contains: a. Stand ........................................................... Qty. 1 b. Apron ........................................................... Qty. 1 c. Screw, M3 x 6 mm ...................................... Qty. 2 d. Washer, #5 x .5 OD................................. ...

  • Honeywell MS9540 Voyager - page 18

    14 S TAND K ITS Assembly There are two options for assembling the stand. The first option is a self- supporting stand that can be moved freely a bout on the countertop. The secon d option is used if the stand will be bo lt ed or hard-mounted to the countertop. Stand Option 1: Self-Supported Stand Kit #46-46128 Step 1 Slide the apron over the stand. ...

  • Honeywell MS9540 Voyager - page 19

    15 S TAND K ITS Assembly Stand Option 2: Hard-Mount Kits #46-46128 and #46-46351 Step 3 Screw the stand anchor onto the base assembly until it sits flush. Step 4 Remove the logo plate on the stand b y gently using an exacto knife to releas e the plate hook. Step 5 Position the stand over the base assembly. Step 6 Secure the stand to the base assemb ...

  • Honeywell MS9540 Voyager - page 20

    16 S TAND K ITS Assembly Wall Mount, Option 1: For Kit #46-46508 Step 1 Drill two #39 pilot holes 3. 00 ″ apart. Step 2 Attach the Wall Mount Hanger to the wall with the two #8 wood screws provided. Wall Mount, Option 2: Kit #46-46508 Step 1 Attach the Wall Mount Base to the Wall Mount Hanger with the two 4.8 x 13 mm self-tapping scre ws. Step 2 ...

  • Honeywell MS9540 Voyager - page 21

    17 I NDICATORS Audible When the Voyager is in operation, it provides audi ble feedback. These sounds indicate the status of the scanner . Eight settings are avail able for the tone of the beep (normal, 6 alternate tones and no t one ). To change the beeper tone, refer to the MetroSelect Single-Line Configuration Guide or MetroSet2’s help file s. ...

  • Honeywell MS9540 Voyager - page 22

    18 I NDICATORS Visual Figure 29. LED Configuration The MS9540 has three LED indic ators located on the head of the scanner . The MS9520 has two LED ind icators loca ted on the head of the scann er. When the scanner is in operat ion, the flas hing, or stationary activit y of the LEDs indicates the status of the scanner and the c urrent scan. All LED ...

  • Honeywell MS9540 Voyager - page 23

    19 I NDICATORS Failure Modes Razzberry Tone – On Star t-Up This indicates the scanner has experi enced a flipper/motor failure. Return the unit for repair to an authorized ser vice center. Continuous Razzbe rry Tone with all LEDs Off If, upon power, the scanner emits a c ontinuous razzberry tone, then the scanner has an experienced an electronic ...

  • Honeywell MS9540 Voyager - page 24

    20 C ONFIGURATION M ODES The MS9500 Voyag er has three modes of configuration. • Bar Codes Voyager or Voyager CG can be configured by scanning the bar codes located in the MetroSelect ® Single-Line Conf iguration Guide ( MLPN 00-02544). This manual can be do wnloaded for FREE at www.metrologic.com. • MetroSet ® 2 This user-friendly Windo ws-b ...

  • Honeywell MS9540 Voyager - page 25

    21 C ONFIGURATION M ODES 4. During configur ation, the motor and laser turn off. YOU CANNOT SCAN A BAR CODE WHILE IN SERIAL CONFIGURATION MODE. 5. There is a 20 second window bet ween commands. If a 20 second timeout occurs, the scanner will send a [nak] and you must start over. 6. To enter serial configuratio n mode, sen d the following command [s ...

  • Honeywell MS9540 Voyager - page 26

    22 C ONFIGURATION M ODES EXAMPLE #3 : The following example sho ws the events that occur when an invalid bar co de is sent. This sample will load the factory default settings and then set the baud rate to 19200. FEATURE HOST COMM AND ASCII REPRESENTATION SCANNER RESPONSE Enter Configuration Mode [stx]999999[etx] 02h 39h 39h 39h 39h 39h 39h 03h [ack ...

  • Honeywell MS9540 Voyager - page 27

    23 U PGRADING THE F IRMWARE The Voyager series is part of Metrologic's line of scanners with flash upgr adeable firmware. The upgrade process requir es a new firmware file supplied to the customer by a customer service representative  and Metrologic's MetroSet 2 software  . A personal computer running Windo ws 95 or greater with ...

  • Honeywell MS9540 Voyager - page 28

    24 D EPTH OF F IELD M INIMUM B AR C ODE E LEMENT W IDTH A B C D E F G H J K mm .13 .15 - - .19 - .25 .33 .53 - mils 5.2 5.7 - - 7.5 - 10 13 21 - Figure 30. Depth of Field ...

  • Honeywell MS9540 Voyager - page 29

    25 IR A CTIVATION R ANGE The scanner's laser will turn off if the scanner has been idle. When the scanner's IR detects movement in the activation area ( see figur e below ), the laser will automatically turn on, prepar ing the sca nner for bar code recogn ition, decoding, and transmission. The default laser/ scan mode for the MS9500 serie ...

  • Honeywell MS9540 Voyager - page 30

    26 A PPLICATIONS AND P ROTOCOLS The model number on each scann er includes the scanner number a nd factory default communication protoc ol. Scanner Version Identifi er Communication Protoc ol(s) 00 Laser Emulation and RS232 Transmit/Receive 11 RS485  , RS232 - TXD, RXD, RTS, CTS 14 RS232 - TXD, RXD, RTS, CTS, DTR, DS R 38 Low Speed USB, Serial E ...

  • Honeywell MS9540 Voyager - page 31

    27 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Me tro or 1- 800-436-3876 to pres erve the limited warranty terms. Symptoms Possible Causes Solution All Interfaces No power is being supplied to the unit. Check the transformer, the outlet and power strip. Make sure the ca ...

  • Honeywell MS9540 Voyager - page 32

    28 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The unit powers up, but does not scan and/or beep. The bar code being scanned does not satisfy the configured criteria for character length lock or minimum length. Verify that the bar code being scanned falls into the configured criteria. The scanner defaults to a minimum of 3 character b ...

  • Honeywell MS9540 Voyager - page 33

    29 T ROUBLESHOOTING G UIDE Symptoms Possible Causes Solution The following four items are relevant for a Keyboard Wedge interface only. The unit scans but the data is not correct. The unit’s configuration is not correct. Make sure that the proper PC type AT, PS2 or XT is selected. Verify the correct country code and data format is selected. Adjus ...

  • Honeywell MS9540 Voyager - page 34

    30 RS232 D EMONSTRATION P ROGRAM If an RS232 scanner is not communicating with an IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are work ing. This program is for demonstration purp oses only. It is only intended to prove that cabling is correct, the COM port is working, and the scanner is work ...

  • Honeywell MS9540 Voyager - page 35

    31 D ESIGN S PECIFICATIONS MS9500 Series Specifications O PERATIONAL Light Source Visible Laser Diode 650 nm Laser Power: Less than 1 mW (peak) Depth of Scan Field: 0 mm - 203 mm (0" - 8") for 0.330 mm (13 mil) bar code at default settings Scan Speed: 72 scan lines per second Scan Pattern: Single scan line Minimum Bar Width: 0.127 mm (5.0 ...

  • Honeywell MS9540 Voyager - page 36

    32 D ESIGN S PECIFICATIONS MS9500 Series Specifications M ECHANICAL Length: 198 mm (7.8") Width: Handle - 45 mm (1.8"), Head - 78 mm (3.1") Depth: 40 mm (1.6") Weight: 149 g (5.25 oz) E LECTRICAL Input Voltage: 5VDC ± 0.25V Operating = 0.825 W typical Power: Standby = 0.600 W typical Operating = 165 mA @ 5VDC typical Current: S ...

  • Honeywell MS9540 Voyager - page 37

    33 D EFAULT S ETTINGS Many functions of the scanner can be configu red or enabled/disa bled. The scanner is shipped from the factor y c onfigured to a set of default conditions. All default parameters of t he scanner have a n asterisk ( * ) marked in the default column. If an asterisk is not in the default column then the default setting is off or ...

  • Honeywell MS9540 Voyager - page 38

    34 D EFAULT S ETTINGS Parameter Default RS232 Light Pen RS485 KBW USB Laser Emulatio n Mod 43 Check on Code 39       MSI-Plessy 10/10 Check Digit       MSI- Pless y Mod 10 Check Digit *       Paraf Support ITF       ITF Symbol Lengths Variable       Minimum Sy ...

  • Honeywell MS9540 Voyager - page 39

    35 D EFAULT S ETTINGS Parameter Default RS232 Light Pen RS485 KBW USB Laser Emulatio n Same symbol rescan timeout: 750 msecs       Same symbol rescan timeout: 875 msecs *       Same symbol rescan timeout: 1000 msecs       No Same sy mbol timeout       Infinite Same symbol timeo ...

  • Honeywell MS9540 Voyager - page 40

    36 D EFAULT S ETTINGS Parameter Default RS232 Light Pen RS485 KBW USB Laser Emulation Transmit Sanyo ID Characters   Nixdorf ID   LRC Enabled   UPC Prefix   UPC Suffix   Carriage Return *   Line Feed-Disabled by default in KBW *   Tab Prefix   Tab Suffix   “DE” Disable Command  “FL” L ...

  • Honeywell MS9540 Voyager - page 41

    37 D EFAULT S ETTINGS Parameter Default RS232 Light Pen RS485 KBW USB Laser Emulation 100 msec to Find Supplement Configurable in 100 mse c step s (max 800 msec) *       Coupon Code 128  as code 39    as code 39 † Configurable Code Lengths 7 avail       † Code Selects w ith configurable Code Lengt ...

  • Honeywell MS9540 Voyager - page 42

    38 1 10 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS95 x 0-41 RS232 and Light Pen Emulation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input/LTPN Source 7 Reserved 8 LTPN Data 9 +5VDC The MS9520 and MS9540 scanner interfaces terminate to a 10-pin modular jack. The serial # l ...

  • Honeywell MS9540 Voyager - page 43

    39 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections MS95 x 0-00 Laser Emulation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 Flip Sense/Start of Scan Output 5 Proximity Detect/Trigger Emulation O utput 6 Scan/Laser Enable Input 7 Reserved 8 Data Out 9 +5VDC 10 Shield Ground MS95 x 0-14 RS232 MS95 x 0-40 Full Spe ...

  • Honeywell MS9540 Voyager - page 44

    40 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configuration (Host End) RS232 PowerLink Cable MLPN 53-53000 x -3 Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input/Light Pen Source 5 Signal Ground 6 Light Pen Data (DSR Out for -14 interfaces) 7 CTS Input 8 RTS Output 9 +5VDC 9-Pin Female, D-Type USB Cables ...

  • Honeywell MS9540 Voyager - page 45

    41 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configuration (Host End) Keyboard Wedge Po werLink Cable MLPN 53-53002 x -3 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 Volts DC 5-Pin DIN, Female Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 Volts DC 5 PC Clock 6 No Connect 6-Pin DIN, Male Metrologic ...

  • Honeywell MS9540 Voyager - page 46

    42 L IMITED W ARRANTY The MS9500 Voyager and Voy ager CG series scanners are manufactured by Metrologic at its Suzhou China facility. The MS9500 Voyager and Voyager CG series scanners have a fiv e (5) year limited warranty from the date of manufacture . Metrologic w arrants and represents th at all MS9500 Voyager and Voyager CG series scanne rs are ...

  • Honeywell MS9540 Voyager - page 47

    43 R EGULATORY C OMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adj ustments or performan ce of procedures other than tho se specified herein may result in hazar dous laser light ex posure. U nder no circumst ances shoul d the customer attempt to s ...

  • Honeywell MS9540 Voyager - page 48

    44 R EGULATORY C OMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment. Class A Devices The follo wing is applicabl e when the scann er cable is g reater in lengt ...

  • Honeywell MS9540 Voyager - page 49

    45 R EGULATORY C OMPLIANCE EMC Changes or modifications not expressly approved by the party respo nsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable w hen the scanner cable is les s than 3 meters (9.8 feet) in length w hen full y extended: Les instructions ci-de ssous s’ap ...

  • Honeywell MS9540 Voyager - page 50

    46 P ATENTS This METROLOGIC product may be covere d by, but not limited to, one or more of the following US Patents: US Patent No. 5,081,342; 5,260,55 3; 5,340,971; 5,340, 973 ; 5,424,525; 5,468,951; 5,484,992; 5, 525, 789; 5,528,024; 5,591,95 3; 5,616,9 08; 5,627,359; 5,661,292; 5,777,315; 5, 789,730; 5,7 89,731; 5,811,78 0; 5,825,0 12; 5,828,048; ...

  • Honeywell MS9540 Voyager - page 51

    47 I NDEX A AC .................................. see power accessories ............................... 2, 3 adapter .......................................... 2 C cable .............................. 2–3, 27–29 adapter ...................................... 2 communication ... 1, 2–3, 5, 7–11, 29, 33, 38–41 disconnec t .................. ...

  • Honeywell MS9540 Voyager - page 52

    48 I NDEX P parameter .............................. 33–37 pin assi gnments .............. see cable power ...................... 2, 7–11, 27, 32 PowerLink...................41, see cable protocols ..................... see interfac e R razzberry tone ............. see indicator Red LED ...................... see indicator regulatory compliance ...

  • Honeywell MS9540 Voyager - page 53

    49 ...

  • Honeywell MS9540 Voyager - page 54

    ...

  • Honeywell MS9540 Voyager - page 55

    April 2008 Printed in China 00 - 024 10 K ...

  • Honeywell MS9540 Voyager - page 56

    January 2008, Version 03 Printed in the USA 00 - 024 10 J ...

Fabbricante Honeywell Categoria Barcode readers

I documenti che otteniamo dal fabbricante del dispositivoHoneywell MS9540 Voyager possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Honeywell
- manuali per l’uso MS9540 Voyager
- schede prodotto Honeywell
- opuscoli
- o etichette energetiche Honeywell MS9540 Voyager
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Honeywell MS9540 Voyager.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Honeywell MS9540 Voyager, manuali di manutenzione, brevi manuali o manuali utente Honeywell MS9540 Voyager. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Honeywell MS9540 Voyager.

Manuali per l’uso simili

Manuale completo del dispositivo Honeywell MS9540 Voyager, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Honeywell MS9540 Voyager dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Honeywell MS9540 Voyager.

Il manuale per l’uso completo Honeywell, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Honeywell MS9540 Voyager - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Honeywell MS9540 Voyager, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Honeywell MS9540 Voyager che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Honeywell MS9540 Voyager - che ci dovrebbe aiutare nei primi passi durante l'uso Honeywell MS9540 Voyager
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Honeywell MS9540 Voyager
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Honeywell MS9540 Voyager in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Honeywell MS9540 Voyager?

Utilizza il modulo sottostante

Se non hai risolto il problema con Honeywell MS9540 Voyager con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Honeywell MS9540 Voyager è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)