  • Invacare IRC 1730 - page 1

    Dealer: This manual MUST be given to the end user . User: BEFORE using this product, read this manual and save for future refere nce. For more information regarding Invacare products, parts, and services, please visit www.invacare.com Operator’s Manual Stratos™Portable Plus Compressor Nebulizer System Model Number: IRC 1730 ...

  • Invacare IRC 1730 - page 2

    Stratos™Portable Plus 2 Part No 1150755  WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UN DERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. IF YOU A ...

  • Invacare IRC 1730 - page 3

    TABLE OF CONTENTS Part No 1150755 3 Stratos™Portable Plus TABLE OF CONTENTS SPECIAL NOTES ............................................... 5 INTRODUCTION .............................................. 6 REGISTER YOUR PRODUCT .............................. 7 FEATURES ....................................................... 8 TYPICAL PRODUCT PARAMETE ...

  • Invacare IRC 1730 - page 4

    TABLE OF CONTENTS TABLE OF CONTENTS Stratos™Portable Plus 4 Part No 1150755 Battery Specifications ............. ............................................. ............. 21 Conditioning the Battery ....... ............................................. ............. 23 Using the Battery ..................... .................................... ...

  • Invacare IRC 1730 - page 5

    SPECIAL NOTES Part No 1150755 5 Stratos™Portable Plus SPECIAL NOTES Signal  w ords  are  used  in  this  manual  and  apply  to  hazards  or  unsafe  practices  which  could  result  in  personal  injury  or  property  damage.  Refer  to  the  table  below  for ? ...

  • Invacare IRC 1730 - page 6

    INTRODUCTION Stratos™Portable Plus 6 Part No 1150755 INTRODUCTION Yo u r  Inv acare  Stratos  Portable  Plus  Compressor  Nebulizer  System  is  the  latest  in  portable  compressor  nebulizer  technology .  Th e  purpose  of  the  nebulizer  system  is  to  convert  you ...

  • Invacare IRC 1730 - page 7

    REGISTER YOUR PRODUCT Part No 1150755 7 Stratos™Portable Plus REGISTER YOUR PRODUCT The benefits of registering include: 1. Safeguarding your investment. 2. Ensuring long-term maintenance and servicing of your product. 3. Receiving updates with product information, maintenance tips and industry news. Register ONLINE at warranty.invacare.com Pleas ...

  • Invacare IRC 1730 - page 8

    FEATURES Stratos™Portable Plus 8 Part No 1150755 FEATURES Inlet Air Filter AC/DC Power Outlet On/Off Button Compressor Outlet ...

  • Invacare IRC 1730 - page 9

    TYPICAL PRODUCT PARAMETERS Part No 1150755 9 Stratos™Portable Plus TYPICAL PRODUCT PARAMETERS NOTE:  *Weight  is  without  nebulizer  and  tubing. SOUND LEVEL: 58 dBA OPERATING TEMPERATURE RANGE: 50°F - 104°F (10°C to 40°C); 1 0 to 95% RH FOAM INTA KE FILTER: Expanded Polyurethane SAFETY SYSTEMS: High temperature compressor ...

  • Invacare IRC 1730 - page 10

    SUPPLEMENTAL INFORMATION Stratos™Portable Plus 10 Part No 1150755 SUPPLEMENTAL INFORMATION Compressor If  the  unit  shuts  down  frequently  or  fails  to  start,  you  may  have  a  low  v oltage  situation.  Low  voltage  can  also  be  suspected  when: •T h e  compresso ...

  • Invacare IRC 1730 - page 11

    HANDLING Part No 1150755 11 Stratos™Portable Plus HANDLING Shipping Instructions The  shipping  container  has  been  designed  to  assure  protection  of  this  device. If  this  device  is  to  be  reshipped  by  common  carrier ,  it  should  be  packed  in  the  ...

  • Invacare IRC 1730 - page 12

    SECTION 1—IMPORTANT SAFEGUARDS Stratos™Portable Plus 12 Part No 1150755 SECTION 1—IMPORTANT SAFEGUARDS  WARNING SECTION 1 - IMPORTANT SAF EGUARDS contains important information for the safe operation and use of this product. CAUTION “Caution:  Federal  law  restricts  this  device  to  sale  or  rental  by ? ...

  • Invacare IRC 1730 - page 13

    SECTION 1—IMPORTANT SAFEGUARDS Part No 1150755 13 Stratos™Portable Plus  DANGER Risk  of  electric  shock.  DO  NOT  disassemble.  Refer  servicing  to  qualified  service  personnel. FIRE  RISK ‐ DO  NOT  use  this  product  in  an  ox ygen  enriched  environment  ...

  • Invacare IRC 1730 - page 14

    SECTION 1—IMPORTANT SAFEGUARDS Stratos™Portable Plus 14 Part No 1150755  WARNING To Reduce the Risk of Burns, Electrocution, Fire and Injury to Persons: This  product  should  NEVER  be  left  unatten ded  when  plugged  in. Close  supervision  is  necessary  when  this  product  is  used ? ...

  • Invacare IRC 1730 - page 15

    SECTION 1—IMPORTANT SAFEGUARDS Part No 1150755 15 Stratos™Portable Plus  WARNING NEVER  block  the  air  openings  of  the  product  or  place  it  on  a  soft  surface,  such  as  a  bed  or  couch,  where  the  air  openings  may  be  blocked.  Keep  the ...

  • Invacare IRC 1730 - page 16

    SECTION 1—IMPORTANT SAFEGUARDS Stratos™Portable Plus 16 Part No 1150755  WARNING When  not  administering  treatment,  keep  out  of  the  reach  of  small  children.  Some  of  the  parts  of  the  nebulizer  system  are  small  enough  for  children  to  swallow ...

  • Invacare IRC 1730 - page 17

    SECTION 2—OPERATING INSTRUCTIONS Part No 1150755 17 Stratos™Portable Plus SECTION 2—OPERATING INSTRUCTIONS  WARNING Remove the compress or from the carr ying case before use. DO NOT operate unit without filter. Avoid operating this produc t in a dusty environment. Otherwise, premature comp ressor wear could occur. Setup NOTE:  For  t ...

  • Invacare IRC 1730 - page 18

    SECTION 2—OPERATING INSTRUCTIONS Stratos™Portable Plus 18 Part No 1150755  WARNING DO NOT exceed the maximum a llowed quantity of six ml of medication. The maximum capacity of the nebulizer medication cup is 6 ml. CAUTION NEVER pour medication into the compressor outlet. Damage to the comp ressor will occur. 5. Add  the  prescribed  ...

  • Invacare IRC 1730 - page 19

    SECTION 2—OPERATING INSTRUCTIONS Part No 1150755 19 Stratos™Portable Plus 10. T o  use  with  battery ,  charge  for  6  hours.  Refer  to  Conditioning  the  Battery  on  page 23. 11. T o  use  the  nebulizer  system  with  the  AC  power  cord,  connect  the  power ...

  • Invacare IRC 1730 - page 20

    SECTION 2—OPERATING INSTRUCTIONS Stratos™Portable Plus 20 Part No 1150755 1. Sit  in  a  relaxed  and  upright  position.  2. T urn  on  the  device  by  pushing  the  On/Off  button.  3. Begin  treatment  by  placing  the  nebulizer  mouthpiece  between  you r  teeth ? ...

  • Invacare IRC 1730 - page 21

    SECTION 3—BATTERIES Part No 1150755 21 Stratos™Portable Plus SECTION 3—BATTERIES Battery Specifications The  optional  battery  used  with  the  Inv acare  Stratos  Po r ta b l e  Plus  Nebulizer  System  requires  a  few  simple  precautions  to  ensure  proper  operation  and ? ...

  • Invacare IRC 1730 - page 22

    SECTION 3—BATTERIES Stratos™Portable Plus 22 Part No 1150755 CAUTION In case of failure and/or malfun ction, turn the unit off and read the operating manual. DO NOT attempt to open the plastic case or to re place any components. DO NOT short circuit batte ry contacts. Make sure battery contacts DO NOT co me in contact with keys, coins or other ...

  • Invacare IRC 1730 - page 23

    SECTION 3—BATTERIES Part No 1150755 23 Stratos™Portable Plus Conditioning the Battery NOTE:  The  definition  of  conditioning  the  battery  is  simply  charging  the  battery  for  a  full  six  hour  cycle  before  the  initia l  use  of  the  product. 1. Disconnect  ...

  • Invacare IRC 1730 - page 24

    SECTION 3—BATTERIES Stratos™Portable Plus 24 Part No 1150755 Using the Battery NOTE:  For  this  procedure,  refe r  to  FIGURE  3.1  on  page  24. 1. Fit  the  front  hook  on  the  battery  top  into  the  recess  on  the  bottom  of  the  compressor . 2. Press  ...

  • Invacare IRC 1730 - page 25

    SECTION 3—BATTERIES Part No 1150755 25 Stratos™Portable Plus Charging the Battery NOTE:  For  this  procedure,  refe r  to  FIGURE  3.1  on  page  24. 1. Press  in  the  release  button  on  the  front  of  the  battery  pack  and  separate  the  battery  from  the ...

  • Invacare IRC 1730 - page 26

    SECTION 4—CLEANING AND DISINFECTING Stratos™Portable Plus 26 Part No 1150755 SECTION 4—CLEANING AND DISINFECTING Following  the  cleani ng  instructions  after  each  use  will  prevent  any  remaining  medication  in  the  bottle  from  drying  and  causing  the  device  to  n ...

  • Invacare IRC 1730 - page 27

    SECTION 4—CLEANING AND DISINFECTING Part No 1150755 27 Stratos™Portable Plus 2. Disassemble  nebulizer  chamber  by  turning  counterclockwise  and  separating. 3. Fill  tw o  plastic  containers  or  bowls: A. W ashing:  Hot  water/detergent  solution. B. Soaking:  Hot  w ater/vinegar  solu ...

  • Invacare IRC 1730 - page 28

    SECTION 4—CLEANING AND DISINFECTING Stratos™Portable Plus 28 Part No 1150755 Cleaning the Mouthpiece 1. Boil  the  mouthpiece  in  wat e r  for  a  maximum  of  five  minutes  or  autoclave  at  a  maximum  of  121°  C  for  ten  minutes. 2. Allow  the  mouthpiece  to  ...

  • Invacare IRC 1730 - page 29

    SECTION 4—CLEANING AND DISINFECTING Part No 1150755 29 Stratos™Portable Plus  WARNING Unplug unit before cleaning. DO NOT clean using abrasive cleaners. DO NOT submerge in water to clean. Clean outer case with damp cloth. CAUTION If fluid gets into the area around the comp ressor outlet, wipe the area off with a dry cloth and let the nebuliz ...

  • Invacare IRC 1730 - page 30

    SECTION 5—MAINTENANCE Stratos™Portable Plus 30 Part No 1150755 SECTION 5—MAINTENANCE  DANGER DO NOT remove the compressor case. Failure to comply could result in electrical sh ock. All disassembly MUST be performed by an authorized Invacare service center.  WARNING All maintenance on your Inva care Stratos Portable Plus Nebulizer system ...

  • Invacare IRC 1730 - page 31

    SECTION 5—MAINTENANCE Part No 1150755 31 Stratos™Portable Plus Storage 1. Put  the  nebulizer  and  mouthpiece  in  the  carrying  case. 2. Coil  the  air  tubing. 3. W rap  the  AC  cord  in  a  coil. 4. Zip  the  bag  closed. 5. Store  the  device  in  a  safe  area ...

  • Invacare IRC 1730 - page 32

    SECTION 6—TROUBLESHOOTING Stratos™Portable Plus 32 Part No 1150755 SECTION 6—TROUBLESHOOTING PROBLEM SOLUTION Nebul izer ov erhea ts. Th e nebulizer has an interna l thermal protector to prevent the device from overheating. If the internal temperature reaches the preset level, the uni t will automatically shut down, and the power L ED will t ...

  • Invacare IRC 1730 - page 33

    SECTION 6—TROUBLESHOOTING Part No 1150755 33 Stratos™Portable Plus Nebulizer does not work, and the light indicator is red. The thermal protector has been activated due to: a. The device operating outside the condit ions outlined in this manual. b. The device has bee n operating near heat sources or in hot environments. Allow the nebulize r to ...

  • Invacare IRC 1730 - page 34

    LIMITED WARRANTY Stratos™Portable Plus 34 Part No 1150755 LIMITED WARRANTY PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the original purchaser who purchases this product when new and unused from Invacare Corporation or a dealer ...

  • Invacare IRC 1730 - page 35

    LIMITED WARRANTY Part No 1150755 35 Stratos™Portable Plus For warranty servic e, please contact th e Invacare service department during normal business hours at the toll-free telephone number identified on th e back cover of this manual. Upon receiving notice of a n alleged defe ct in a product, In vacare will issue a serialized return authorizat ...

  • Invacare IRC 1730 - page 36

    THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER, WHETHER EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER, SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PURSUANT ...

Fabbricante Invacare Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoInvacare IRC 1730 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Invacare
- manuali per l’uso IRC 1730
- schede prodotto Invacare
- opuscoli
- o etichette energetiche Invacare IRC 1730
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Invacare IRC 1730.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Invacare IRC 1730, manuali di manutenzione, brevi manuali o manuali utente Invacare IRC 1730. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Invacare IRC 1730.

Manuale completo del dispositivo Invacare IRC 1730, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Invacare IRC 1730 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Invacare IRC 1730.

Il manuale per l’uso completo Invacare, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Invacare IRC 1730 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Invacare IRC 1730, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Invacare IRC 1730 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Invacare IRC 1730 - che ci dovrebbe aiutare nei primi passi durante l'uso Invacare IRC 1730
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Invacare IRC 1730
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Invacare IRC 1730 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Invacare IRC 1730?

Utilizza il modulo sottostante

Se non hai risolto il problema con Invacare IRC 1730 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Invacare IRC 1730 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine