Manuale per l’uso Siemens OPTISET E MEMORY

28 pagine 0.14 mb
Scarica

Vai alla pagina of 28

Summary
  • Siemens OPTISET E MEMORY - page 1

    Hicom 118 optiset E standar d optiset E ad v ance / ad v ance plus optiset E memor y s ...

  • Siemens OPTISET E MEMORY - page 2

    2 ...

  • Siemens OPTISET E MEMORY - page 3

    3 User Guide Introduction .............................................................................................. 5 Executive / Secretary Features .............................................................. 7 Dial Executive / Dial Secretary ................................................................ 7 Answering Calls for Executive/s ...

  • Siemens OPTISET E MEMORY - page 4

    4 User Guide - Cont’ d Optional Features .................................................................................. 22 Programming Keys ................................................................................. 22 System Abbreviated Dialling .................................................................. 23 Last Number Redial .. ...

  • Siemens OPTISET E MEMORY - page 5

    5 Intr oduction This guide is designed to assist extension users on a Siemens Hicom 118 Communication System to use all authorised features. Your extension may not be authorised ∗ ∗ ∗ ∗ ∗ to use all features. The Siemens representative can confirm features that are available to you. ∗ ∗ ∗ ∗ ∗ - authorised features are those feat ...

  • Siemens OPTISET E MEMORY - page 6

    6 Intr oduction - Cont’ d The telephones are easily recognised by three dialogue keys namely: ✔ Yes Key Forward Scroll Key Backward Scroll Key The Siemens optiset E Digital Feature telephones operate via a Menu- controlled User Guidance Display System. The display will automatically offer you a choice of the available options most suited to the ...

  • Siemens OPTISET E MEMORY - page 7

    7 Dial Executive / Dial Secretary The Dial Exec / Dial Secr keys have multiple functions These keys provide direct access to the Executive or Secretary without using the Transfer option. The LED indicates when the Executive or Secretary is busy on a call. Transfer a Call to the Executive or Secretary. - press Dial Executive / Dial Secretary key - a ...

  • Siemens OPTISET E MEMORY - page 8

    8 Ans wering Calls f or Ex ecutive/s When the Secretary is FREE , calls for the Executive/s will ring on the Secretary’s extension. Answer Call for Executive/s when FREE CALL from: external ans. incoming call? - Exec LED will flash on Secretary extension - lift handset or press Speaker key Transfer the call - press Dial Executive key - announce t ...

  • Siemens OPTISET E MEMORY - page 9

    9 Exec Ring er Options Incoming calls for the Executive may be routed in several ways for answering:- 1 Ring on Secretary’s extension 2 Ring on Executive’s extension 3 Ring on both extensions 4 Ring on any other selected extension Ring on Secretary’s extension - press Exec Ringer key on Secretary extension - Exec Ringer LED is on Incoming cal ...

  • Siemens OPTISET E MEMORY - page 10

    10 Call Forwar ding / Diver t This feature allows for 3 types of forwarding, or diversion, of your calls to an extension of your choice. If the Secretary is diverting calls to a destination which is different from the Executive’s destination then the Exec Ringer key must not be pressed. Programme Call Forwarding / Divert - press Divert key divers ...

  • Siemens OPTISET E MEMORY - page 11

    11 Internal and External Dialling Handset Operation - lift handset, listen for internal dial tone - dial the required extension number or external number preceded by line access code (code is normally 0 ) Handsfree Operation - do not lift handset - dial the required extension number or external number preceded by line access code (code is normally ...

  • Siemens OPTISET E MEMORY - page 12

    12 Call T ransf er You may transfer an internal or external call from your extension to any other extension or to the switchboard. Transfer to a Free Extension (Announcing the Call) - press ✔ ✔ ✔ ✔ ✔ key to confirm enquiry option - dial required extension - announce the call and replace handset Transfer to a Free Extension (Call not Annou ...

  • Siemens OPTISET E MEMORY - page 13

    13 Call T ransf er - Cont’ d If the extension remains busy or unanswered the call will automatically be transferred back to your extension. recalling from: 23 ans incoming call? - lift handset ...

  • Siemens OPTISET E MEMORY - page 14

    14 Enquiry Call This feature allows you to hold an existing call, dial another extension or an external number, conduct a conversation without the original caller overhearing, and then return to the original caller. This call can also be converted to a 3 Way conference . Activate Enquiry Call - press ✔ ✔ ✔ ✔ ✔ key to confirm enquiry optio ...

  • Siemens OPTISET E MEMORY - page 15

    15 3 W ay Conference You are engaged on a call and wish to include a third party. The third party may be either external or internal. Activate Conference - you are engaged on a call - scroll to set up Conference option - press ✔ ✔ ✔ ✔ ✔ key please dial return to held call - dial required extension or 0 and external number ext 12 Conferenc ...

  • Siemens OPTISET E MEMORY - page 16

    16 Call Pic kup The Call Pickup feature allows you to answer any ringing extension in your pickup group from your telephone. Activate Call Pickup An extension within your pickup group is ringing - Call Pickup LED flashes - a ping ring will also alert you to an incoming call CALL for: 23 group pickup? - lift handset, listen for internal dial tone - ...

  • Siemens OPTISET E MEMORY - page 17

    17 T ransfer a Second Caller Answer Second Call If you are busy on a call when the Call Pickup LED flashes and you wish to answer the waiting call. - ask existing caller to hold - press Call Pickup key - first call is placed on hold - second call is now on the line external return to held call? Transfer Second Call - scroll to enquiry? option - pre ...

  • Siemens OPTISET E MEMORY - page 18

    18 Call P ark This feature allows you to Park an external or internal call on your extension to be retrieved at any extension or from the switchboard. There are 10 Park positions (0-9 on keypad). Park a Call - press Park key plus location number (0-9) - replace handset - call is now parked Retrieve a Parked Call before Recall - lift handset, listen ...

  • Siemens OPTISET E MEMORY - page 19

    19 Call Bac k Call Back requests can be left on extensions which have been rung and not answered or are busy. Activate Call Back Busy - called extension is busy - press ✔ ✔ ✔ ✔ ✔ key to confirm Call Back? option CALL BACK set - replace handset or press Release key The system will automatically call you back when both your extension and th ...

  • Siemens OPTISET E MEMORY - page 20

    20 Call Forwar ding / Diver t This feature allows for 3 types of forwarding, or diversion, of your calls to an extension of your choice. Programme Call Forwarding / Divert - press Divert key diversion type: 1=all calls? - scroll to required type of forwarding (1,2 or 3) - press ✔ ✔ ✔ ✔ ✔ key to confirm to: - enter required extension numbe ...

  • Siemens OPTISET E MEMORY - page 21

    21 Electr onic T elephone Loc k This feature allows you to lock your extension by dialling your code, which prevents unauthorised use of your extension. The initial or default code is 00000. Set your Lock Code - dial ∗ ∗ ∗ ∗ ∗ 93 - dial default Lock Code (00000) - dial new Lock Code (5 digits) - dial new Lock Code again Lock your Extensio ...

  • Siemens OPTISET E MEMORY - page 22

    22 Pr ogramming Ke ys Spare keys on the optiset E telephone and on the add-on Key Module are available for programming of direct dialling numbers, internal or external. Hicom Function keys These keys are programmable by yourself for any required Hicom features. Programme Function keys - dial ∗ ∗ ∗ ∗ ∗ 91 - press required key to be program ...

  • Siemens OPTISET E MEMORY - page 23

    23 System Abbre viated Dialling The system allows for the storage of 256 external telephone numbers. By utilising the System Abbreviated Dialling, you will be permitted to dial specific numbers that would be outside your normal trunk barring limits. Use the System Abbreviated Dialling - select the relevant access code from the Abbreviated Dialling ...

  • Siemens OPTISET E MEMORY - page 24

    24 Night Ser vice When the Night Bell rings - dial ∗ ∗ ∗ ∗ ∗ 423 - you are now connected to the caller Check with System Administrator if any other type of Night Service is operational. V olume / T one Settings The Plus and Minus keys allow for the individual setting of the levels of speech, ringing and ring tones. Change Handsfree volume ...

  • Siemens OPTISET E MEMORY - page 25

    25 ...

  • Siemens OPTISET E MEMORY - page 26

    26 optiset E memor y ...

  • Siemens OPTISET E MEMORY - page 27

    27 Electr onic Notebook Programme External Numbers and Names - press MENU key - press 8 key - enter required name - press 8 key - enter required number (preceded by 0 for external no.) - press 8 key - enter additional information (i.e. company name or cell number) - press 8 key (up to 5 rows can be used for other information) - press END key to exi ...

  • Siemens OPTISET E MEMORY - page 28

    28 Siemens Telecommunications (Pty) Ltd. Private Bag X71 Halfway House 1685 ...

Fabbricante Siemens Categoria Telephone

I documenti che otteniamo dal fabbricante del dispositivoSiemens OPTISET E MEMORY possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Siemens
- manuali per l’uso OPTISET E MEMORY
- schede prodotto Siemens
- opuscoli
- o etichette energetiche Siemens OPTISET E MEMORY
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Siemens OPTISET E MEMORY.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Siemens OPTISET E MEMORY, manuali di manutenzione, brevi manuali o manuali utente Siemens OPTISET E MEMORY. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Siemens OPTISET E MEMORY.

Manuali per l’uso simili

Manuale completo del dispositivo Siemens OPTISET E MEMORY, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Siemens OPTISET E MEMORY dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Siemens OPTISET E MEMORY.

Il manuale per l’uso completo Siemens, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Siemens OPTISET E MEMORY - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Siemens OPTISET E MEMORY, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Siemens OPTISET E MEMORY che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Siemens OPTISET E MEMORY - che ci dovrebbe aiutare nei primi passi durante l'uso Siemens OPTISET E MEMORY
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Siemens OPTISET E MEMORY
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Siemens OPTISET E MEMORY in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Siemens OPTISET E MEMORY?

Utilizza il modulo sottostante

Se non hai risolto il problema con Siemens OPTISET E MEMORY con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Siemens OPTISET E MEMORY è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)