Manuale per l’uso Field Controls UV-12HP

12 pagine 0.8 mb
Scarica

Vai alla pagina of 12

Summary
  • Field Controls UV-12HP - page 1

    UV-AIRE™ AIR PURIFYING SYSTEM Mode l: UV-12C,18C,28C, 28,12HP,18HP,28HP,12H PC,18HPC,28HPC READ THESE INSTRUCTIONS CAREFULLY AND COMPLETE LY BEFORE PROCEEDING WITH THE INSTALLATION LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE. DO NOT INSTALL THI ...

  • Field Controls UV-12HP - page 2

    Page 2 I. INDICATION FOR USE This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or co ndition nor for use in the mitigation, treatment, or pr evention of any disease or condition. II. GENERAL INFORMATION There are different size units avail able, depending on t he squ are footage of your home. See ch ...

  • Field Controls UV-12HP - page 3

    Page 3 III. INSTALLATION 1. Locate a suitable location for the unit downstream from t he ‘A’ coil in the supply plenum or in the return plenum; preferably downstream from the air filter. For optimum “clea n ing” effect on the ‘A’ coil, mount the unit in the supply plenum as close as possible to the ‘A’ coil. (See Figu re 1) Figure 1 ...

  • Field Controls UV-12HP - page 4

    Page 4 2. Determine the type of duct you have. (For flex duct applications, refer to Figure 26 on page 11) I F YOU HAVE METAL DUCT : a. Apply supplied wet and stick mounting template to air d uct in either a vertical or horizontal position as shown in Figure 2. b. Drill 1/8” diameter mounting hole s at positions indicated on template. c. Cut out ...

  • Field Controls UV-12HP - page 5

    Page 5 3. Remove base unit and cover from box. 4. Apply supplied “Duct Se al Kit” according to instructions included in kit. (See Figure 12) 5. Determine whether to use flat or angled bracket. (Refe r to “Bulb Mounting Bracket Selection” in Section VI for aid in this decision ) a. Flat Bracket Installation i. Remove the two hex nuts and fla ...

  • Field Controls UV-12HP - page 6

    Page 6 8. Insert lamp t hrough the hole until lam p cannot be inserted any further. (See Figure 16) 9. Swing the swivel bracket over the end of lamp. Hand-tighten the wing nut o n the stud. Be careful no to over tighten the wing nut. The po rcelain at the lamp base may crack when over tightened. (See Figure 17) 10. Plug ballast plug into end of lam ...

  • Field Controls UV-12HP - page 7

    Page 7 13. Close the cover and tighten co ver screw. (See Figure 21) 14. Plug the power cord into a standard electrical outlet. NOTE: Seal the joints an d seams of the plenum near the mounting location to reduce any direct viewing of light. (See Figure 1) 15. Press the power switch to the “ON” posi tion. (Light on switch should be on indicating ...

  • Field Controls UV-12HP - page 8

    Page 8 V. ALARM CIRCUIT WIRING The UV Aire units supplied with a circuit board allo ws for the wi ring of the UV Aire unit into an alarm or security system to monitor the operation of the UV lamp. This circuit is a set of normal open conta cts that close if the operational time exceeds 90 00 hrs or if th e lamp burns out. 1. Turn off power switch o ...

  • Field Controls UV-12HP - page 9

    Page 9 Chart A VI. BULB MOUNTING BRACKET SELECTION The UV-AIRE TM units come with an a ngled mounting bracket and flat mount ing bracket to position the bul b either straight or at an angle. Cho ose one or the other br acket method be st suited for your needs. Refer to the configurations chart below when making your selection. A NGLED L AM P M OUNT ...

  • Field Controls UV-12HP - page 10

    Page 10 VII. MAINTENANCE 1. Inspect and clean lamp at least every 6 months. 2. Replace your UV-Aire™ Ai r Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously fo r maximum lamp life and light effectiveness. VIII. REPLACEM ENT PROCEDURE VERY IMPORTANT: Turn switch on unit to “OFF? ...

  • Field Controls UV-12HP - page 11

    Page 11 IX. TROUBLESHOOTING GUIDE 1. If the LED is illuminating a “YELLOW” color a nd the ci rcuit board alarm beeps every 15 minutes, the lamp shoul d be replaced soon. 2. If the LED is illuminating a “RED” col or and the circui t board ala rm beeps every 5 minutes, the lamp sho uld be replaced immediately. 3. If the lamp does not light up ...

  • Field Controls UV-12HP - page 12

    Page 12 WARRANTY INFORMATION The health aspects associa ted with the use of these products and t heir ability to aid in di sinfecting of environmental air have not been investigated b y UL. P/N 46453400 Rev E 10/05 Limited  Warranty  Field  Controls,  L.L.C.  warrants  that  the  following  Field  Controls,  L.L.C. ...

Fabbricante Field Controls Categoria Air Cleaner

I documenti che otteniamo dal fabbricante del dispositivoField Controls UV-12HP possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Field Controls
- manuali per l’uso UV-12HP
- schede prodotto Field Controls
- opuscoli
- o etichette energetiche Field Controls UV-12HP
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Field Controls UV-12HP.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Field Controls UV-12HP, manuali di manutenzione, brevi manuali o manuali utente Field Controls UV-12HP. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Field Controls UV-12HP.

Manuale completo del dispositivo Field Controls UV-12HP, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Field Controls UV-12HP dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Field Controls UV-12HP.

Il manuale per l’uso completo Field Controls, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Field Controls UV-12HP - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Field Controls UV-12HP, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Field Controls UV-12HP che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Field Controls UV-12HP - che ci dovrebbe aiutare nei primi passi durante l'uso Field Controls UV-12HP
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Field Controls UV-12HP
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Field Controls UV-12HP in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Field Controls UV-12HP?

Utilizza il modulo sottostante

Se non hai risolto il problema con Field Controls UV-12HP con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Field Controls UV-12HP è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)