Manuale per l’uso IBM eServer System x3650 M3 7945K4G

21 pagine Non applicabile
Scarica

Vai alla pagina of 21

Summary
  • IBM eServer System x3650 M3 7945K4G - page 1

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 1 Product Guide March 2010 IBM System x 3650 M3 Product Overvie w CONTENT S Product Overvie w 1 Selling Features 2 Key ...

  • IBM eServer System x3650 M3 7945K4G - page 2

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 2 Serial over LA N ; as well as text-console redirect over LA N . Another improv ement with the ne w genera tion of X-A ...

  • IBM eServer System x3650 M3 7945K4G - page 3

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 3 • A choice of either standard 1.5V D IMMs, or 1.35V D IMMs that consume 10% less energy . • Four available high- ...

  • IBM eServer System x3650 M3 7945K4G - page 4

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 4 memory is up to 16 X better than st andard ECC memory a t correcting me mory errors. This can help reduce dow ntime c ...

  • IBM eServer System x3650 M3 7945K4G - page 5

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 5 Also available, via configure-to-orde r (CTO): • 130W 4-core X eon 5600 model X5 677 running at 3.46GH z, with impr ...

  • IBM eServer System x3650 M3 7945K4G - page 6

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 6 slots ( 192GB in 12 slots, as of 2Q/ 2010), or up to 24GB of UDIMM (un buffered DIMM) memory in 12 slots ( 48GB in 12 ...

  • IBM eServer System x3650 M3 7945K4G - page 7

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 7 with six 2GB single - rank DIMM s by 7% for SPECjbb2 005. Dual-rank DIM Ms are also better than quad-ran k DIMMs beca ...

  • IBM eServer System x3650 M3 7945K4G - page 8

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 8 updated/patched much like firmwar e. Licensing works the same as for “standard” ESX . Disk Controllers All x3650 ...

  • IBM eServer System x3650 M3 7945K4G - page 9

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 9  Superior Uptime – 3X the availability of mechanical di sk drives – No moving part s to fail – Enterprise w ...

  • IBM eServer System x3650 M3 7945K4G - page 10

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 10 capability for future up grades to Fi bre Channel ove r Ethernet (FCoE) an d iSCSI protocol of floads. By using a co ...

  • IBM eServer System x3650 M3 7945K4G - page 11

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 11 components, in cluding: • Redundant me mory protect ion (with Chipkill protec tion, and memory mi rroring enabled) ...

  • IBM eServer System x3650 M3 7945K4G - page 12

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 12 and operating sy stems personaliz ation. IBM offers ex tensive technical su pport by phone and via the W eb. Support ...

  • IBM eServer System x3650 M3 7945K4G - page 13

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 13 the ability to add more tools to the bootable image and to automatical ly download the bootable environment if nee d ...

  • IBM eServer System x3650 M3 7945K4G - page 14

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 14 processor. Hard Disk Drives — IBM hard disk drive s help you improv e the transaction and cost performance of you ...

  • IBM eServer System x3650 M3 7945K4G - page 15

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 15 IBM System x3650 M3 Images Front View Inside View Rear View Hot-Swap Pow er Supplies USB Hypervisor Key Hot-Swap HDD ...

  • IBM eServer System x3650 M3 7945K4G - page 16

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 16 IBM System x3650 M3 Specifications Machine ty pe 7945-A2x , B2x, C2x, D2x, F2x, G2 x, H2x, J2x, L2x, M2x , N2x Form ...

  • IBM eServer System x3650 M3 7945K4G - page 17

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 17 (* When availab le in 2Q/2010) 1333MHz RDIMM 2GB single -ran k x4 , 1.5V; 2GB single-rank x 8 1.5V; 2GB dual-rank x ...

  • IBM eServer System x3650 M3 7945K4G - page 18

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 18 # of 33MHz legacy PCI sl ots None # of video ports 2 (one front, one rea r) Video controller Matrox G200 eV (in IMM) ...

  • IBM eServer System x3650 M3 7945K4G - page 19

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 19 The Bottom Line The IBM Syste m x3650 M3 is an extremely energy efficient, powerful syste m, incorporating significa ...

  • IBM eServer System x3650 M3 7945K4G - page 20

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 20  Advanced Chipki ll ECC memory protection support  Memory mirroring • Integrated ServeRA ID controller — e ...

  • IBM eServer System x3650 M3 7945K4G - page 21

    Leadership en terprise server with significantly lower co st of own ership in a h ighly available a nd expandab le, rack-dense, 2 U dual-socket server Please see the Legal Information section for important notices and information. 21 For More Information IBM System x Servers ht tp:// ibm.com /sy stems/x IBM Systems Direc tor Service and Support Man ...

Fabbricante IBM Categoria Server

I documenti che otteniamo dal fabbricante del dispositivoIBM eServer System x3650 M3 7945K4G possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici IBM
- manuali per l’uso eServer System x3650 M3 7945K4G
- schede prodotto IBM
- opuscoli
- o etichette energetiche IBM eServer System x3650 M3 7945K4G
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso IBM eServer System x3650 M3 7945K4G.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione IBM eServer System x3650 M3 7945K4G, manuali di manutenzione, brevi manuali o manuali utente IBM eServer System x3650 M3 7945K4G. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto IBM eServer System x3650 M3 7945K4G.

Manuali per l’uso simili

Manuale completo del dispositivo IBM eServer System x3650 M3 7945K4G, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare IBM eServer System x3650 M3 7945K4G dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti IBM eServer System x3650 M3 7945K4G.

Il manuale per l’uso completo IBM, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale IBM eServer System x3650 M3 7945K4G - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice IBM eServer System x3650 M3 7945K4G, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per IBM eServer System x3650 M3 7945K4G che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo IBM eServer System x3650 M3 7945K4G - che ci dovrebbe aiutare nei primi passi durante l'uso IBM eServer System x3650 M3 7945K4G
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del IBM eServer System x3650 M3 7945K4G
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio IBM eServer System x3650 M3 7945K4G in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su IBM eServer System x3650 M3 7945K4G?

Utilizza il modulo sottostante

Se non hai risolto il problema con IBM eServer System x3650 M3 7945K4G con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con IBM eServer System x3650 M3 7945K4G è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)