Manuale per l’uso Dynacord DPA 4140

23 pagine 0.34 mb
Scarica

Vai alla pagina of 23

Summary
  • Dynacord DPA 4140 - page 1

    23 POWER AMPLIFIER DPA 4120 / DPA 4140 OWNER'S MANUAL 40 0 W A TT S P O W E R A M P L I F I E R P R O T E C T S T A ND B Y T E S T D P A 4 140 G R O UND F A U L T C L I P 0d B - 13d B R EA D Y Performance Features Power amplifier with 200 W or 400 W output power according to the IEC 283-3 standard within a 19“ - cabinet (3 HU) providing the ...

  • Dynacord DPA 4140 - page 2

    24 ...

  • Dynacord DPA 4140 - page 3

    25 Indicators, controls and connections 400 W A TT S P O W E R A M P L I F I E R G R O UN D F A U L T C L I P 0d B - 13d B R EA D Y P R O T E C T S T A N D BY T ES T D PA 414 0 8 6 7 1 2 3 4 5 P O W E R + 1 1 5 V / 2 30 V A C 5 0 - 60 H z T 8 A F O R 1 15 V T 4 A F O R 2 30 V G R O U ND E D U N G R O UND E D CH AS S I S S W I T CH C I RC U I T T O ...

  • Dynacord DPA 4140 - page 4

    26 19 CIRCUIT ⊥ TO CHASSIS SWITCH 20 DC INPUT 24V = (battery) 21 IDENT ADDRESS switch 22 REMOTE CONTROL connectors 23 STATUS indicator A locking screws power supply printed board B locking screws INPUT MODULE Contents Performance Features ............................................................................................................. ...

  • Dynacord DPA 4140 - page 5

    27 14.3 NRS 90222 remote module ......................................................................................................... 69 14.4 NRS 90224 pilot tone and ground fault surveillance ........................................................................ 70 15. Warranty ................................................................ ...

  • Dynacord DPA 4140 - page 6

    28 DPA 4120 : For 115V AC operation, the mains fuse (11) has to be replaced by a slow blowing 4 ampere type , labeled " T4A " (see also paragraph 11.1). DPA 4140 : For 115V AC operation, the mains fuse (11) has to be replaced by a slow blowing 8 ampere type , labeled " T8A " (see also paragraph 11.2). If the appliance is correct ...

  • Dynacord DPA 4140 - page 7

    29 figure 1 connections of the input sockets figure 2 LF cable for coupling two amplifiers DPA 41xx 5. Outputs 5.1 POWER OUTPUT The power output is balanced and off-ground potential. The output is factory-configured for the connection of 100V loudspeaker systems. Connection has to be performed by inserting the supplied 5-pole plug into the power ou ...

  • Dynacord DPA 4140 - page 8

    30 of 200W (connection impedance 50 ohms) with the DPA 4120, respectively 400W (connection impedance 25 ohms) with the DPA 4140. Connection is performed using the 100V output (17) (see also figure 3). In a few special cases it is also possible to operate the loudspeaker systems with 70V or 50V output voltage (see also paragraph 7). Caution It is po ...

  • Dynacord DPA 4140 - page 9

    31 6.1 STANDBY indicator When the appliance is correctly connected and mains and/or battery power is present, the green STANDBY indicator (4) will light. 6.2 READY indicator Both amplifiers, the DPA 4120 and the DPA 4140, employ power-on switching delays of approximately 3 sec. to effectively eliminate power-on switching noise. After this time, the ...

  • Dynacord DPA 4140 - page 10

    32 output bridge B411 to 100 V B407 70 V B408 50 V B409 4 ohms B410 table 1 bridge B411 settings figure 5 coding-bridges S405 / S406 settings switching the output voltage output recognitio n OUTPUT CONFIG Caution It is possible that during operation shock-hazard output voltages can be present at the POWER OUTPUT connector (>34V peak value). Thus ...

  • Dynacord DPA 4140 - page 11

    33 Note: Functioning changes in the models DPA 4120 (starting with serial numbers: 100 11) and DPA 4140 (starting with serial numbers: 100 11) in association with the input module NRS 90225: To achieve reliable attenuation of switching noise (knacks), the monitor output stays muted as long as the READY -relay is not pulled. Because of circuit desig ...

  • Dynacord DPA 4140 - page 12

    34 - re-insert the input module and tighten the locking screws (B). 8.4 NRS 90227 output transformer for the floating, balanced monitor output In case that floating monitor outputs are required, the outputs of the INPUT MODULE NRS 90225 and REMOTE MODULE NRS 90222 are prepared for retrofitting output transformers. If so, it is necessary to addition ...

  • Dynacord DPA 4140 - page 13

    35 Output Transformer NRS 90227 figure 6 printed board assemb ly 81338 showing the input transformer NRS 90208 and the output transformer NRS 90 227 Input Transformer NRS 90208 Output Transformer 90 227 figure 7 printed board assembly 81339 showing the input transformer NRS 90208 and the output transformer NRS 90 227 8.5 NRS 90224 pilot tone & ...

  • Dynacord DPA 4140 - page 14

    36 When off-ground potential loudspeaker cable networks are employed we recommend insulation-monitoring using the ground fault surveillance module NRS 90224. Error recognition: An occurring ground fault either signals that one of the cables is damaged - which most likely point towards a total line interruption in the near future - or that connectio ...

  • Dynacord DPA 4140 - page 15

    37 figure 8 printed board assembly 84187 in the DPA 4120 showing the NRS 90224 pilot tone & ground fault surveillance and the bridges B411 and S405, S406 for switching the output voltage; inserted B 411 ...

  • Dynacord DPA 4140 - page 16

    38 NRS 90 224 figure 9 printed board assembly 84175 in the DPA 4140 showing the NRS 90224 pilot tone & ground fault surveillance and the bridges B411 and S405, S406 for switching the output voltage; inserted Checking the pilot tone surveillance function: When the NRS 90224 is installed and the power amplifier is switched on, the green READY ind ...

  • Dynacord DPA 4140 - page 17

    39 Checking the ground fault surveillance function: When the NRS 90224 is installed and the power amplifier is switched on, the green READY indicator (7) has to light. Utilizing an external switch to connect one pole of the 100V-loudspeaker network via a 47 k ohms resistor for approximately 5 seconds to ground potential, the corresponding red GROUN ...

  • Dynacord DPA 4140 - page 18

    40 F 503 F 502 figure 10 printed board assembly 85270 in the DPA 4120 showing the DC fuses F502 and F503 ...

  • Dynacord DPA 4140 - page 19

    41 F 503 F 502 figure 11 printed board assembly 85268 in the DPA 4140 showing the DC fuses F502 and F503 ...

  • Dynacord DPA 4140 - page 20

    42 F 601 F 602 figure 12 printed board assemblies 86243 DPA 4120 and DPA 4140 showing the AC fuses F601 and F602 Caution Before opening the appliance, make sure to disconnect the mains and/or battery power source! Replacing the fuses F502 and F503 (only to be carried out by the experienced service technician!) The battery fuses F502 and F503 are lo ...

  • Dynacord DPA 4140 - page 21

    43 Caution For security reasons it is necessary to ensure that, after the installation is completed, all wiring located beneath the power supply input PCB are within a distance of at least 6 mm to the printed board assembly. 12. Specifications 12.1 DPA 4120 power amplifier 200 W power supply: mains operation 115 V / 230 V~ AC, ±10 % mains frequenc ...

  • Dynacord DPA 4140 - page 22

    44 ambient temperature range +5 °C .. +40 °C dimensions (W x H x D) 483 x 132 x 345 mm depth with / without connections max. 400 mm / max. 340 mm weight without extensions 13.2 kg finish anthracite 12.2 DPA 4140 power amplifier 400 W power supply: mains operation 115 V / 230 V~ AC, ± 10 % mains frequency 50 - 60 Hz security class I mains operati ...

  • Dynacord DPA 4140 - page 23

    45 interfering voltage (A) ≤ 1.2 mV = -56 dBu features of the monitor output: electronically balanced nominal output voltage 2 V = + 8.2 dBu nominal load impedance 600 ohms ambient temperature range +5 °C .. +40 °C dimensions (W x H x D) 483 x 132 x 345 mm depth with / without connections max. 400 mm / 340 mm weight without extensions 16.7 kg f ...

Fabbricante Dynacord Categoria Car Amplifier

I documenti che otteniamo dal fabbricante del dispositivoDynacord DPA 4140 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Dynacord
- manuali per l’uso DPA 4140
- schede prodotto Dynacord
- opuscoli
- o etichette energetiche Dynacord DPA 4140
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Dynacord DPA 4140.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Dynacord DPA 4140, manuali di manutenzione, brevi manuali o manuali utente Dynacord DPA 4140. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Dynacord DPA 4140.

Manuali per l’uso simili

Manuale completo del dispositivo Dynacord DPA 4140, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Dynacord DPA 4140 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Dynacord DPA 4140.

Il manuale per l’uso completo Dynacord, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Dynacord DPA 4140 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Dynacord DPA 4140, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Dynacord DPA 4140 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Dynacord DPA 4140 - che ci dovrebbe aiutare nei primi passi durante l'uso Dynacord DPA 4140
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Dynacord DPA 4140
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Dynacord DPA 4140 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Dynacord DPA 4140?

Utilizza il modulo sottostante

Se non hai risolto il problema con Dynacord DPA 4140 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Dynacord DPA 4140 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)