    Page 1 12431-7-0107 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL F AN TYPE DIRECT VENT W ALL FURNACE MODEL DV -55SPP EFFECTIVE DA TE JANUAR Y 2007 Th is ap pl ia n ce ma y be in st al le d in an af te rm ar k et , pe rm an en tl y lo ca te d, man uf ac tu r ed hom e (U SA only) or mobile home, where not prohibited by state or local codes. Th ...

  • Langley/Empire DV-55SPP - page 2

    Page 2 12431-7-0107 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas ...................................................................................................... 4 Requirements for Massac ...

  • Langley/Empire DV-55SPP - page 3

    Page 3 12431-7-0107 THIS IS A HEA TING APPLIANCE DO NOT OPERA TE THIS APPLIANCE WITHOUT FRONT P ANEL INST ALLED. • Due to high temperatures the appliance should be located out of traffic and away from furnitur e and draperies. • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burn ...

  • Langley/Empire DV-55SPP - page 4

    Page 4 12431-7-0107 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the area ...

  • Langley/Empire DV-55SPP - page 5

    Page 5 12431-7-0107 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above ? ...

  • Langley/Empire DV-55SPP - page 6

    Page 6 12431-7-0107 Introduction Always consult your local Building Department regarding regula - tions, codes or ordinances which apply to the installation of a direct vent wall furnace. Instructions to Installer 1. Installer must leave instruction manual with owner after instal - lation. 2. Installer must have owner fill out and mail warranty ca ...

  • Langley/Empire DV-55SPP - page 7

    Page 7 12431-7-0107 Locating Gas Supply The gas line can enter the unit either through the floor or outside wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Note: Never use plastic pipe. Check to confirm whether your loca ...

  • Langley/Empire DV-55SPP - page 8

    Page 8 12431-7-0107 Clearances 1. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. 2. The DV -55 minimum wall depth is 4 1/2 inches and maximum wall depth is 13 inches. The use of tubes not supplied by the manufacturer results in unsatisfactory performance. ...

  • Langley/Empire DV-55SPP - page 9

    Page 9 12431-7-0107 Locating W all Opening The furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The furnace is 16 inches in width and normal 16 inches on center studs will not allow the furnace to be recessed into the wall unless a stud is repositioned. The wall opening required ...

  • Langley/Empire DV-55SPP - page 10

    Page 10 12431-7-0107 Cutting V ent T ubes This is the most important part of the installation. With the furnace installed on wall the 6" diameter air inlet tube and the 4" diam- eter flue outlet tube are to be marked and cut using the following procedure. 1. Attach 6" diameter air inlet tube onto the collar of air drop assembly . Be ...

  • Langley/Empire DV-55SPP - page 11

    Page 1 1 12431-7-0107 4. Apply furnace cement to 4" diameter flue outlet collar on combustion chamber and to 4" diameter collar on vent cap. Attach 4" diameter flue outlet tube onto flue outlet collar on combustion chamber . Attach vent cap into the 4" diameter flue outlet tube. Attach vent cap to outside mounting plate with ...

  • Langley/Empire DV-55SPP - page 12

    Page 12 12431-7-0107 1. STOP! Read the safety information above. 2. Set the thermostat to lowest setting. 3. T urn off all electric power to the appliance. 4. Remove control access panel (lower front panel). 5. T urn gas control knob clockwise to "OFF ." 6. W ait ten (10) minutes to clear out any gas. Then smell for gas, including near th ...

  • Langley/Empire DV-55SPP - page 13

    Page 13 12431-7-0107 The correct flame will be a short blue inner flame with a much larger light blue outer flame. The main burner (Figure 12) shows the approximate height of each part of the flame for each gas. The burner does not have a primary air adjustment. The flame will be correct if the factory-set pressure and orifice opening are use ...

  • Langley/Empire DV-55SPP - page 14

    Page 14 12431-7-0107 Figure 13 Wiring The appliance, when installed, must be electrically grounded in ac- cordance with local codes or , in the absence of local codes, with the National Electrical Code, ANSI/NFP A 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a thr ee-prong ...

  • Langley/Empire DV-55SPP - page 15

    Page 15 12431-7-0107 Replacing Fan and Oiling the Motor The fan motor sho uld be cleaned and oil ed once each heatin g season. T o reach the motor, withdraw the metal shroud surrounding the fan blade by removing the screws on each side. Oil holes are located on the top at each end of the motor . Use a few drops of #10 motor oil. T o clean the motor ...

  • Langley/Empire DV-55SPP - page 16

    Page 16 12431-7-0107 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. I n d ex P a r t N o . Number Description USE ONL Y MANUF ACTURER'S REPLACEMENT P ARTS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. 1 1 1762 Outer Casing T op 2 632024 Motor Mount (Four Required) 3 1 1764 M ...

  • Langley/Empire DV-55SPP - page 17

    Page 17 12431-7-0107 P AR TS VIEW ...

  • Langley/Empire DV-55SPP - page 18

    Page 18 12431-7-0107 SER VICE NOTES ...

  • Langley/Empire DV-55SPP - page 19

    Page 19 12431-7-0107 SER VICE NOTES ...

  • Langley/Empire DV-55SPP - page 20

    Page 20 12431-7-0107 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com ...

Fabbricante Langley/Empire Categoria Furnace

I documenti che otteniamo dal fabbricante del dispositivoLangley/Empire DV-55SPP possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Langley/Empire
- manuali per l’uso DV-55SPP
- schede prodotto Langley/Empire
- opuscoli
- o etichette energetiche Langley/Empire DV-55SPP
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Langley/Empire DV-55SPP.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Langley/Empire DV-55SPP, manuali di manutenzione, brevi manuali o manuali utente Langley/Empire DV-55SPP. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Langley/Empire DV-55SPP.

Manuali per l’uso simili

Manuale completo del dispositivo Langley/Empire DV-55SPP, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Langley/Empire DV-55SPP dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Langley/Empire DV-55SPP.

Il manuale per l’uso completo Langley/Empire, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Langley/Empire DV-55SPP - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Langley/Empire DV-55SPP, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Langley/Empire DV-55SPP che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Langley/Empire DV-55SPP - che ci dovrebbe aiutare nei primi passi durante l'uso Langley/Empire DV-55SPP
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Langley/Empire DV-55SPP
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Langley/Empire DV-55SPP in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Langley/Empire DV-55SPP?

Utilizza il modulo sottostante

Se non hai risolto il problema con Langley/Empire DV-55SPP con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Langley/Empire DV-55SPP è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)