Manuale per l’uso Oregon Scientific BPW128

15 pagine 0.51 mb
Scarica

Vai alla pagina of 15

Summary
  • Oregon Scientific BPW128 - page 1

    GB 1 mmHg 60 80 100 120 140 160 180 200 220 / min 2 1 21.2 22.2 85 90 158 92 110 155 93 112 10:05 10:12 x x x x x x LOG BOOK : Age: Weight: kg/lbs ...

  • Oregon Scientific BPW128 - page 2

    2 GB BOLD BOLD LEYENDA : - INCREMENTO RÁPIDO - DESTELLANDO - PULSAR BOTÓN - PULSAR MANTENER OPRIMIDO EL BOTÓN ES BOLD BOLD LEGEND : - FAST INCREMENT - FLASHING - PRESS BUTTON - PRESS AND HOLD BUTTON GB BOLD BOLD LEGENDE : - AUGMENTATON RAPIDE - CLIGNOTEMENT - APPUYER SUR LE BOUTON - APPUYER SANS LACHER SUR LE BOUTON F ...

  • Oregon Scientific BPW128 - page 3

    GB 3 INFORMATION CONCERNING THE CE SYMBOL This device complies with the European regulations based on the Medical Products Code, and bears the CE mark “CE0123”. The device has been quality inspected according to EG guideline 93/42/EWG and tested in compliance to the EN1060-1 Non-invasive sphygmomanometers-Part 1, General requirements and EN1060 ...

  • Oregon Scientific BPW128 - page 4

    4 GB DESCRIPTION AND FUNCTION OF PARTS A. Liquid Crystal Display (LCD) and protective cover - Large easy-reading display - 5 functional symbols - Systolic [SYS/mmHg], Diastolic [DIA/mmHg], Mean [MAP/mmHg], Pulse [pul/min.]and date & time display. B. Battery compartment Houses two (2) LR03 /AAA/ UM4 size 1.5V batteries C. Button - For time adjus ...

  • Oregon Scientific BPW128 - page 5

    GB 5 DISPLAY-SYMBOL DESCRIPTION Memory Mark Weak Battery Inflating Mark Air releasing Pulse Mark INSTALLING BATTERIES 1. Slide battery cover off. 2. Install batteries first. Ensure correct polarity. Battery Type: 2 Alkaline LR03 (AAA)size 3. Replace the cover. Replace the batteries if: 1. the weak battery mark appears in the display 2. nothing appe ...

  • Oregon Scientific BPW128 - page 6

    6 GB PROPER EQUIPMENT SETUP 1. Remove all watches, jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff sh ould be wrapped on bare skin for correct measurements. 2. Apply cuff to left wrist with palm facing up. 3. Make sure the edge of the cuff is about 1 cm from the plam. 4. In order to ensure accur ...

  • Oregon Scientific BPW128 - page 7

    GB 7 WHAT IS MEAN ARTERIAL PRESSURE (MAP) The Mean Arterial Pressure is the average pressure forcing blood through the arteries. It is not the average of the systolic and diastolic blood pressure. It corresponds to a state of balance between the compressive and expansive forces acting on the arterial wall when there is no distension of the arterial ...

  • Oregon Scientific BPW128 - page 8

    8 GB MEASUREMENT With the individual in a sitting position and with the cuff attached as previously mentioned, a blood pressure reading can be obtained. Note: - For accurate pressure measurement, take blood-pressure readings in a seated position. Avoid leaning back while the measurement is being taken. - Ensure that the lower arm is raised so that ...

  • Oregon Scientific BPW128 - page 9

    GB 9 HOW TO TAKE MEASUREMENT Refer to Fig1 Fig1 2sec Fig1 ...

  • Oregon Scientific BPW128 - page 10

    10 GB Note: 1. Remove all watches, jewelry, etc. prior to attaching the wrist monitor. Clothing sleeves should be rolled up and the cuff should be wrapped on bare skin for correct measurements. 2. Apply cuff to left wrist with palm facing up. 3. Make sure the edge of the cuff is about 1 cm from the plam. 4. In order to ensure accurate measurements, ...

  • Oregon Scientific BPW128 - page 11

    GB 11 HOW TO SET THE TIME Refer to Fig3 Fig 3 mode ...

  • Oregon Scientific BPW128 - page 12

    12 GB AUTOMATIC POWER OFF The device will automatically switch off after about 1 minute. However, to conserve battery power, press the button whe n finished to turn the unit off. ERROR MESSAGES Display Err 1 Err 2, 8, 12, 13, 14, 15 Err 3 Err 4 Err 5, 6, 7 Err 9, 10,11 Description Deflation period too long Incorrect measurement Cuff is not fastened ...

  • Oregon Scientific BPW128 - page 13

    GB 13 SPECIFICATIONS Measuring method : Oscillometric / non-invasive Application : Adults Measurement location : Wrist section of lower arm Circumference (approx. ) 5.3"-7.7"(13.5-19.5cm) Pressure Measuring range : 30 - 280mmHg Pulse Measuring Range : 30 - 200 pulse/min Accuracy : (Pressure) +/- 3mmHg (Pulse) +/- 5% Operating environment ...

  • Oregon Scientific BPW128 - page 14

    14 GB Should you require assistance regarding this product and its operation, please contact our Customer Care Department at 1-800-853-8883 or via email at helpme@oscientific.com. WARRANTY This product is warranted to be free of manufacturing defects for a period of 12 months from date of retail purchase. Defective product should be directed to the ...

  • Oregon Scientific BPW128 - page 15

    GB 15 measurement again, ensure that the cuff is properly attached, the arm is in the proper position and that movement has been minimized during the measurement process. If the device does not function: - Check that the unit is on. After about 3 minutes of inactivity, the unit will automatically turn off. - Ensure that batteries are properly inser ...

Fabbricante Oregon Scientific Categoria Blood Pressure Monitor

I documenti che otteniamo dal fabbricante del dispositivoOregon Scientific BPW128 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Oregon Scientific
- manuali per l’uso BPW128
- schede prodotto Oregon Scientific
- opuscoli
- o etichette energetiche Oregon Scientific BPW128
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Oregon Scientific BPW128.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Oregon Scientific BPW128, manuali di manutenzione, brevi manuali o manuali utente Oregon Scientific BPW128. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Oregon Scientific BPW128.

Manuali per l’uso simili

Manuale completo del dispositivo Oregon Scientific BPW128, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Oregon Scientific BPW128 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Oregon Scientific BPW128.

Il manuale per l’uso completo Oregon Scientific, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Oregon Scientific BPW128 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Oregon Scientific BPW128, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Oregon Scientific BPW128 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Oregon Scientific BPW128 - che ci dovrebbe aiutare nei primi passi durante l'uso Oregon Scientific BPW128
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Oregon Scientific BPW128
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Oregon Scientific BPW128 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Oregon Scientific BPW128?

Utilizza il modulo sottostante

Se non hai risolto il problema con Oregon Scientific BPW128 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Oregon Scientific BPW128 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine