    Dealer: This manual must be given to the end user. User: Before using this concentrator, re ad this manual and save for future reference. Operator's Manual For more information regarding Invacare products, parts, and services, please visit www.invacare.com Platinum ™ Oxygen Concentrators Standard, with /SensO 2 ® and HomeFill ® Model IRC5L ...

  • Invacare IRC5LXO2AW - page 2

    WARNING Platinum ™ 2 Part No 113486 6  WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UN DERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. IF YOU ARE ...

  • Invacare IRC5LXO2AW - page 3

    TABLE OF CONTENTS Part No 1134866 3 Platinum ™ TABLE OF CONTENTS SPECIAL NOTES ............................................... 5 RECYCLING INFO RMATION ............................. 6 SECTION 1—GENERAL GUIDELINES ..................... 7 Maintenance ......................... ...................................................... ........... 9 Ra ...

  • Invacare IRC5LXO2AW - page 4

    TABLE OF CONTENTS Platinum ™ 4 Part No 113486 6 Routine Maintenanc e ....................... ................................................. 27 SECTION 7—TROUBLES HOOTING GUIDE ............ 31 LIMITED WARRANTY .................................... 33 ...

  • Invacare IRC5LXO2AW - page 5

    SPECIAL NOTES Part No 1134866 5 Platinum™ SPECIAL NOTES Signal  words  are  used  in  this  manual  and  apply  to  hazards  or  unsafe  practices  which  could  result  in  personal  injury  or  property  damage.  Refer  to  the  following  table  for  definit ...

  • Invacare IRC5LXO2AW - page 6

    RECYCLING INFORMATION Platinum™ 6 Part No 1134866 RECYCLING INFORMATION This  product  has  been  supplied  from  an  environmentally  aw are  manufacturer  that  complies  with  the  Wa s t e  Electrical  and  Electronic  Equipment  (WEEE)  Directive  2002/96/CE. This  pro duct ? ...

  • Invacare IRC5LXO2AW - page 7

    SECTION 1—GENERAL GUIDELINES Part No 1134866 7 Platinum™ SECTION 1—GENERAL GUIDELINES  WARNING SECTION 1 - GENERAL GU IDELINES contains important information for the safe operation and use of this product. In  order  to  ensure  the  safe  installation,  assembly  and  operation  of  the  Platinum  co ...

  • Invacare IRC5LXO2AW - page 8

    SECTION 1—GENERAL GUIDELINES Platinum™ 8 Part No 1134866  WARNINGS The  use  of  oxygen  therapy  requires  that  special  care  be  take n  to  reduce  the  risk  of  fire.  Any  materials  that  will  burn  in  air ,  and  some  that  will  not,  are  ...

  • Invacare IRC5LXO2AW - page 9

    SECTION 1—GENERAL GUIDELINES Part No 1134866 9 Platinum™ Fill  humidifier  with  wa t e r  to  the  lev el  shown  by  the  manufacturer .  DO  NOT  overfill. Keep  unit  at  least  7.5  cm  (3  in)  aw ay  from  w alls,  draperies,  furniture,  and  the  like. ...

  • Invacare IRC5LXO2AW - page 10

    SECTION 1—GENERAL GUIDELINES Platinum™ 10 Part No 1134866 DO  NOT  reach  for  prod uct  that  has  fallen  into  wat e r .  Unplug  IMMEDIA TEL Y . This  device  is  to  be  used  only  in  accordance  with  the  prescription  of  a  physician  and  this  Owner ...

  • Invacare IRC5LXO2AW - page 11

    SECTION 2—FEATURES Part No 1134866 11 Platinum™ SECTION 2—FEATURES Oxygen Purity and Fault Indicator Lights (SensO 2 model)/Fault and Power Indicator Lights (LX model) Circuit Breaker Power Switch Elapsed Time Meter (Hour Meter) Cabinet Filter (one of two shown) Flowmet er Oxygen Out let FRONT VIEW TOP VIEW ACCESSOR IES (NOT SHOWN): HomeFill ...

  • Invacare IRC5LXO2AW - page 12

    SECTION 3—SHIPPING AND HANDLING Platinum™ 12 Part No 1134866 SECTION 3—SHIPPING AND HANDLING NOTE:  For  this  procedure,  refe r  to  FIGURE  3.1  on  page 13. Before  yo u  install  and  operate  the  concentrator ,  please  refer  to  Platinum  Series  Owner ʹ s  Manual. ...

  • Invacare IRC5LXO2AW - page 13

    SECTION 3—SHIPPING AND HANDLING Part No 1134866 13 Platinum™ FIGURE 3.1 Unpacking ...

  • Invacare IRC5LXO2AW - page 14

    SECTION 4—TYPICAL PRODUCT PARAMETERS Platinum™ 14 Part No 1134866 SECTION 4—TYPICAL PRODUCT PARAMETERS Regulatory Listing: EN/IEC 60601-1 Alternating Current Type BF equipment Unit running Unit not running Attention - Consider Accompanying Documents DO NOT smoke Class II, Double Insulation Electrical Requirements: 230 VAC ± 10% (253 VAC/207 ...

  • Invacare IRC5LXO2AW - page 15

    SECTION 4—TYPICAL PRODUCT PARAMETERS Part No 1134866 15 Platinum™ *Oxygen Output Concentration Levels: All 5LXO2AWQ/5LXAW/ 5LXO2AW/9LXO2AWQ models * (Stated concentration levels achieved after in itial warm-up period (approximately 30 minutes). IRC5LXAW, IRC5 LXO2AW and IRC5LXO2AWQ 93% minimu m at 1 to 3 L/min. 91% minimu m at 4 L/min. 87% mini ...

  • Invacare IRC5LXO2AW - page 16

    SECTION 4—TYPICAL PRODUCT PARAMETERS Platinum™ 16 Part No 1134866 Change in maximum recommended flow when back pressure of 7k Pa is applied: 0.7 L/min. Filters: Cabinet (2), Outl et HEPA and Compressor Inlet. Safety System: Current overload or line surge shutdown. High temperature co mpressor shutdown. High Pressure Alarm w/compressor shutdown. ...

  • Invacare IRC5LXO2AW - page 17

    SECTION 4—TYPICAL PRODUCT PARAMETERS Part No 1134866 17 Platinum™ Regulatory Listing : IRC5LXAW/IR C5LXO2AW/ IRC5LXO2AWQ/IRC9LXO2AWQ ETL tested as complying with: EN55011 EN61000-3-2 EN61000-3-3 IEC 60601-1, A1, A2 IEC 60601-1-2 IRC5LXO2AW, IRC5LXO2AWQ, IRC9LXO2AWQ Models Only ISO8359 MDD CE marked models: IRC5LXO2AW, IRC5LXO2AWQ, IRC9LXO2AWQ E ...

  • Invacare IRC5LXO2AW - page 18

    SECTION 4—TYPICAL PRODUCT PARAMETERS Platinum™ 18 Part No 1134866 SENSO 2 INDICATO RS LX INDICATORS LABEL SYMBOL STATUS INDICATOR LIGHTS (LED) SYSTEM OKAY O 2 over 85% (± 2%) GREEN Indicator Light O 2 Between 73% (± 3%) to 85% (±2%) YELLOW Indicator light A. YELLOW Solid B. YELLOW Flashing Sensor Failure Call a qualif ied technician. SYSTEM ...

  • Invacare IRC5LXO2AW - page 19

    SECTION 5—OPERATING INSTRUCTIONS Part No 1134866 19 Platinum™ SECTION 5—OPERATING INSTRUCTIONS Introduction Yo u r  oxygen  concentrator  is  intended  for  individual  use  in  the  home.  It  is  an  electronically  operated  device  that  separates  oxygen  from  room  air . ...

  • Invacare IRC5LXO2AW - page 20

    SECTION 5—OPERATING INSTRUCTIONS Platinum™ 20 Part No 1134866 Recommended Guidelines for Optimum Performance NOTE:  Ensure  that  your  concentrator  is  at  least  7.5  cm  (3  in)  aw ay  from  walls,  drap erie s  or  furniture  to  assur e  sufficient  air  flow .  Av o i ...

  • Invacare IRC5LXO2AW - page 21

    SECTION 5—OPERATING INSTRUCTIONS Part No 1134866 21 Platinum™ Connect Humidifier (If So Prescribed) NOTE:  For  this  procedure,  refe r  to  FIGURE  5.1,FIGURE  5.2,  FIGURE  5.3  on  page 22  and  FIGURE  5.4  on  page 23. 1. Fill  humidifier  with  distilled  wa t e r  t ...

  • Invacare IRC5LXO2AW - page 22

    SECTION 5—OPERATING INSTRUCTIONS Platinum™ 22 Part No 1134866 3. Remove  the  filter  access  door  located  on  the  side  of  the  concentrator .  Insert  a  flathead  screwdriver  in  the  plate  groove  on  th e  top  edg e  of  the  filter  access  door  ...

  • Invacare IRC5LXO2AW - page 23

    SECTION 5—OPERATING INSTRUCTIONS Part No 1134866 23 Platinum™ 6. Attach  oxygen  tubing  from  the  humidifier  bottle  to  oxygen  outlet  connector  on  the  oxygen  concentrator . 7. Attach  the  cannula/patient  supply  tubing  to  the  humidifier  bottle  outlet. 8. After ...

  • Invacare IRC5LXO2AW - page 24

    SECTION 5—OPERATING INSTRUCTIONS Platinum™ 24 Part No 1134866 FIGURE 5.5 Power Switch Flowrate NOTE:  For  this  procedure,  refe r  to  FIGURE  5.6  on  page 25. 1. T urn  the  flowrate  knob  to  the  setting  prescribed  by  you r  physician  or  therapist.  WARNING DO NOT ...

  • Invacare IRC5LXO2AW - page 25

    SECTION 5—OPERATING INSTRUCTIONS Part No 1134866 25 Platinum™ NOTE:  The  use  of  some  accessories  such  as  the  pediatric  flowstand  and  the  HomeFill  compr essor  will  deactivate  the  Low  Flow  Alarm. FIGURE 5.6 Flowrate SensO 2 Oxygen Purity Indicators (LX O 2 Sensor Model ...

  • Invacare IRC5LXO2AW - page 26

    SECTION 5—OPERATING INSTRUCTIONS Platinum™ 26 Part No 1134866 FIGURE 5.7 SensO 2 Oxygen Purity Indicators (LX O 2 Sensor Model) GREEN  light  (O 2 ) ‐ Normal  Operation. YELLOW  light  () ‐ Call  supplier  IMMEDIA TEL Y .  Yo u  may  continue  to  use  the  concentrator  unless  in ...

  • Invacare IRC5LXO2AW - page 27

    SECTION 5—OPERATING INSTRUCTIONS Part No 1134866 27 Platinum™ FIGURE 5.8 Indicators (LX Model) Main Power Loss Alarm System The  alarm  system  contains  no  battery ‐ and  is  thereby  maintenance  free.  The  alarm  system  is  powered  by  a  capacitor  that  is  continuousl ...

  • Invacare IRC5LXO2AW - page 28

    SECTION 6—MAINTENANCE Platinum™ 28 Part No 1134866 SECTION 6—MAINTENANCE NOTE:  The  Invacare  concentrators  are  specifically  designed  to  minimize  rou ti n e  pr eventive  maintenance.  In  places  with  high  dust  or  soot  levels ,  maintenance  may  need  to  be ...

  • Invacare IRC5LXO2AW - page 29

    SECTION 6—MAINTENANCE Part No 1134866 29 Platinum™ 3. Dry  the  filters  thoroughly  before  reinstallation. FIGURE 6.1 Cleaning the Cabinet Filter Cabinet  WARNING Unplug the concentrator when cleaning. To avoid electrical shock, DO NOT remove cabinet. 1. Clean  the  cabinet  with  a  mild  household  cle ...

  • Invacare IRC5LXO2AW - page 30

    SECTION 6—MAINTENANCE Platinum™ 30 Part No 1134866 FIGURE 6.2 Preventive Maintenance Record ON EACH INSPECTION MODEL NO. I R C SERIAL NO. PREVENTIVE MAINTENANCE RECORD INVACARE PLATINUM OXYGEN CONCENTRATOR Record Date of Service Record Elapsed Hours On Hour Meter Clean Cabinet Filter(s) Check Prescribed L/min. Flow Rate EVERY 4,380 HOURS FOR IR ...

  • Invacare IRC5LXO2AW - page 31

    SECTION 7—TROUBLESHOOTING GUIDE Part No 1134866 31 Platinum™ SECTION 7—TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: Main Power Loss: Short beeps, long pause 1. Power cord NOT plugged in. 1. Insert plug i nto outlet. Concentrator not operating, power switch On. 2. No power at outlet. 2 . Inspect house circuit breakers or fus ...

  • Invacare IRC5LXO2AW - page 32

    SECTION 7—TROUBLESHOOTING GUIDE Platinum™ 32 Part No 1134866 YELLOW or RED light illumin ated. Alarm: Continuous On red light only. * Only applies t o SensO 2 models. 1. Low oxygen p urity.* 2. Kinked or blocked tubing, cannula or humidifier.* 3. Flowmeter set at 0.5 L/min. or less.* 4. Unit overheating due to blocked air intake. 5. Insufficien ...

  • Invacare IRC5LXO2AW - page 33

    LIMITED WARRANTY Part No 1134866 33 Platinum™ LIMITED WARRANTY A vailable  At: Belgium  &  Luxemburg: Inv acare  nv ,  Autobaan  22,  B ‐ 8210  Loppem Te l :  (32)  (0)50  83  10  10,  Fax:  (32)  (0)50  83  10  11 belgium@inv acare.com Danmark:  Inv acare  A/S,  Sdr .  Ri ...

  • Invacare IRC5LXO2AW - page 34

    LIMITED WARRANTY Platinum™ 34 Part No 1134866 Italia: Inv acare  Mecc  San  s.r .l.,  Vi a  dei  Pini  62,  I ‐ 36016  Thiene  (VI) Te l :  (39)  0445  38  00  59,  Fax:  (39)  0445  38  00  34 italia@inv acare.com  Nederland: Inv acare  BV ,  Celsiusstraat  46,  NL ? ...

  • Invacare IRC5LXO2AW - page 35

    LIMITED WARRANTY Part No 1134866 35 Platinum™ Switzerland: Mobitec  Rehab  AG,  Benkenstrasse  260,  CH ‐ 4108  Wit t e rs w il Te l . :  (41)  (0)61  487  70  80,  Fax.:  (41)  (0)61  487  70  81 office@mobitec ‐ rehab.ch switzerland@inv acare.com United  Kingdom: Inv acare  Ltd,  S ...

  • Invacare IRC5LXO2AW - page 36

    Invacare Corporation www.invacare.com USA One Invacare Way Elyria, Ohio USA 44036-2125 440-329-6000 800-333-6900 Technical Serv ices 440-329-6593 800-832-4707 Manufacturer: Invacare Medical Equipment (Suzhou) Co., Ltd. Unit 2B, Export Processing Zone No. 200 Suhong Road SIP (Suzhou Industrial Park) Suzhou, Jiangsu, PRC 215021 Tel: 86-512-62586192 F ...

Fabbricante Invacare Categoria Oxygen Equipment

I documenti che otteniamo dal fabbricante del dispositivoInvacare IRC5LXO2AW possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Invacare
- manuali per l’uso IRC5LXO2AW
- schede prodotto Invacare
- opuscoli
- o etichette energetiche Invacare IRC5LXO2AW
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Invacare IRC5LXO2AW.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Invacare IRC5LXO2AW, manuali di manutenzione, brevi manuali o manuali utente Invacare IRC5LXO2AW. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Invacare IRC5LXO2AW.

Manuali per l’uso simili

Manuale completo del dispositivo Invacare IRC5LXO2AW, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Invacare IRC5LXO2AW dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Invacare IRC5LXO2AW.

Il manuale per l’uso completo Invacare, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Invacare IRC5LXO2AW - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Invacare IRC5LXO2AW, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Invacare IRC5LXO2AW che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Invacare IRC5LXO2AW - che ci dovrebbe aiutare nei primi passi durante l'uso Invacare IRC5LXO2AW
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Invacare IRC5LXO2AW
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Invacare IRC5LXO2AW in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Invacare IRC5LXO2AW?

Utilizza il modulo sottostante

Se non hai risolto il problema con Invacare IRC5LXO2AW con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Invacare IRC5LXO2AW è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)