SMC Networks SMC9462TXの取扱説明書

62ページ 0.49 mb
ダウンロード

ページに移動 of 62

Summary
  • SMC Networks SMC9462TX - page 1

    EZ Card1000 1000 Mbps Gigabit Ether net PCI Netw ork Card ◆ High performance for instant acces s to network resources ◆ 1000B ASE-T model for C ategory 5 UTP ◆ Supports PC I 32 and 64-bi t b us-mas ter architectures ◆ Full-duplex operation for up to 2 Gbps o f bandwidt h ◆ IP , TCP and U DP check sum off-loading capability reduces CPU o v ...

  • SMC Networks SMC9462TX - page 2

    ...

  • SMC Networks SMC9462TX - page 3

    6 Hughes Irvine, CA 9261 8 Phone: (9 49) 707-24 00 EZ Card 1000 User Guide From SMC’ s EZ line of feature-rich workgroup LAN solutio ns Mar ch 20 01 Pub. # 1 50416-102 R01 ...

  • SMC Networks SMC9462TX - page 4

    Informati on furnished by SMC Networks, Inc. (SMC) is believed to be accu rate and r eliable. Ho wever , no re sponsibi lity is assumed b y SMC for its us e, no r for a ny inf ringe ment s of pat ents or oth er rig hts of thi rd part ies w hic h may r es ult fr om its use. No lice nse i s gra nted by imp lication or otherwise under any paten t or p ...

  • SMC Networks SMC9462TX - page 5

    L IMITED W ARRAN TY Limited Wa rranty Limited W arranty Statement: SMC Networks, Inc. (“SMC”) warrants its products to be free from d efects in workman ship and m aterials, under nor mal us e and service , for the applicable warranty ter m. All SMC prod ucts carry a standard 90-day limited warranty from the date of pur chase from SMC or its Aut ...

  • SMC Networks SMC9462TX - page 6

    L IMITED W ARRAN TY IN F ACT OR BY OPERA TION OF LA W , ST A TUTOR Y OR OTHER WISE, INCLUDING W ARRAN TIES OR CO NDIT IONS OF ME RCHAN T AB ILITY A ND F ITNES S FOR A P ARTICULAR PUR POSE. SMC N E ITHER A SSUMES NOR A U THORIZE S ANY OTHER PERSON TO A SSUME FOR IT A NY O THER LIABI LITY IN CO NNECT ION W ITH THE SALE, INST A LLA TION, MA INTENANCE ...

  • SMC Networks SMC9462TX - page 7

    i C OMPLIANCES FCC - Class B This equipm ent ha s been t ested and found to co mply with the limits for a Class B dig ital devic e, pur suant to Par t 15 of th e FCC Ru les. The se limi ts ar e desi gned t o pr ovide r ea- sona ble pro tection ag ainst harmful in terference i n a reside ntial insta llation. T his equip- ment genera tes, uses and ca ...

  • SMC Networks SMC9462TX - page 8

    C OMPLIANCES ii Industry Canada - Class B This digital appara tus does not exc eed the Cl ass B lim its for ra dio noi se emiss ions f rom dig ital appar atus as s et out in the inte rference -causi ng equip ment standa rd entit led “Digital Ap paratus, ” ICES-003 o f the D epartment of Communicati ons. Cet app are il nu mériqu e re spect e le ...

  • SMC Networks SMC9462TX - page 9

    iii T ABLE OF C ONTENTS 1 Installing The Network Card . . . . . . . . . . . . . . . 1-1 Intro duction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Hard ware Descr iption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 LED Indi cators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 P ...

  • SMC Networks SMC9462TX - page 10

    iv Network T ype . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Network A ddress . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Jumbo Frame Siz e . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 IEEE Co m pliance. . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Receive B uffer . . . . . . . . . . . . . . . . . . . . ...

  • SMC Networks SMC9462TX - page 11

    1-1 C HAPTER 1 I NSTALLING T HE N ETWORK C ARD Introduction SMC’s EZ Card 1 000 network int erface card is a Gigabi t Ether net card fo r 32 and 64-bit PCI local bus c ompliant com puters. It oper ates u nder the 1 000BAS E-T sp ec ifica tio n over Cat egory 5 UTP Cable . This adap ter pro vides up to t en times th e bandwidth of Fast Ethern et. ...

  • SMC Networks SMC9462TX - page 12

    I NSTAL LING T HE N ETW ORK C ARD 1-2 Hardware Descr iption The EZ Card 1 000 is a Gi gabi t Ethe rnet n etw ork ca rd de signed for 32 and 6 4-bit PCI-bus comput ers. The SMC9462T X has a single RJ-45 con nector to att ach t o C ategor y 5 UTP cabl e an d su ppor ts 10 Mbps , 100 Mbps an d 100 0 Mbp s Ethe rne t oper ation s. It a lso supports ful ...

  • SMC Networks SMC9462TX - page 13

    I NSTA LLING T HE N ETWORK C ARD 1-3 LED Indicators The EZ Card 100 0 network c ard inc ludes stat us LED indicato rs as descr ibed in the foll owing figure and table. Figure 1-2. Statu s LE Ds LED Status Description Link On Green Indicates a valid 1000BASE-T connection on the fiber port. ACT Flashing Green Indicates that the adapter is transmittin ...

  • SMC Networks SMC9462TX - page 14

    I NSTAL LING T HE N ETW ORK C ARD 1-4 Package Contents After unpac king th e EZ Card 10 00, che ck the conte nts of th e box to be sur e you ha ve receive d the f ollowing compone nts: ◆ EZ Card 1000 net work card SM C9462TX ◆ SuperDisk™ network drivers di skette ◆ This Us er Guide ◆ SMC Warranty Registration Card Immediat ely infor m you ...

  • SMC Networks SMC9462TX - page 15

    I NSTA LLING T HE N ETWORK C ARD 1-5 System Require ments Befor e you ins tal l the EZ Ca rd 1000 card , chec k your sy stem f or the foll owin g requ irem ents : ◆ A PC and BI OS that supp ort the PC I Local Bu s Specificat ion v2.2 o r lat er ◆ An available bus-mast ering 32- bit or 64-bi t PCI slot ◆ Cate gory 5 or 5e UTP c able wi th RJ- ...

  • SMC Networks SMC9462TX - page 16

    I NSTAL LING T HE N ETW ORK C ARD 1-6 • Use a 64-bit P CI slot i f your PC sup ports thi s stand ard. • If usin g a 32-bit PCI sl ot, the end of th e card ’ s edge c onnect or will be expos ed. Be caref ul tha t it doe s not to uch a ny conduc ting pa rts on the P C mothe rboard. Note: Some PC mothe rboard desig ns may not provi de adequa te ...

  • SMC Networks SMC9462TX - page 17

    I NSTA LLING T HE N ETWORK C ARD 1-7 4. Replace the cha s sis cov er on yo ur PC an d power it on. 5. Th e EZ Card 10 00 shou ld b e autom atica lly co nfigu red by the host co mpute r ’ s BIOS . Ho weve r , if you ha ve a n olde r comp ut er , you may have to manual ly configu re the com puter ’ s BIOS settin gs. 6. The SMC SuperDisk that acco ...

  • SMC Networks SMC9462TX - page 18

    I NSTAL LING T HE N ETW ORK C ARD 1-8 Connecting Category 5 Cable To con nect to a 1 000BASE-T Gigabit Ethernet device, use the RJ-45 conne ctor on the n etw ork c ard and Cate gory 5, 5 e o r be tter UTP cable. T his conn ectio n can be made dire ctly to the devi ce, or indi rectly vi a a wall outlet that has the proper wiring for an RJ-45 connec ...

  • SMC Networks SMC9462TX - page 19

    I NSTA LLING T HE N ETWORK C ARD 1-9 Connecting UTP Cable 1. Attac h the male RJ- 45 connector on one end of a UT P cable to the net wor k card ’ s RJ-45 port . Figure 1-4. Connecting UTP Cable 2. Attac h the ma le con nector on the other end of th e UTP cable dire ctly to an Ethernet or Fas t Ethe rnet device. OR Attac h the male co nnector on t ...

  • SMC Networks SMC9462TX - page 20

    I NSTAL LING T HE N ETW ORK C ARD 1-10 ...

  • SMC Networks SMC9462TX - page 21

    2-1 C HAPTER 2 I NSTALLING AND C ONFIGURING N ETWORK D RIVERS Windows NT 4.0 In stallation Caution: Prior to inst alli ng the driv er, ma ke sur e you have upgraded to NT Se rvice P ack 4 or later. First-Time Installation If yo u have al ready ins talled a network c ard, configured Windows NT Net working, or conf igured a network dr iver , refer to ...

  • SMC Networks SMC9462TX - page 22

    I NSTAL LING AND C ONFIGURI NG N ETWORK D RIVE RS 2-2 4. Wh en p rompt ed to “ Select a Network Adapter , ” click on “ Have Disk. ” Insert the Sup erDisk when prompted an d click on “ OK. ” 5. Y ou ar e pr ese nted wi th the “ Select OE M Option ” window. Highl ight “ EZ Card 1000 ” and click on “ OK. ” 6. Wh en pr ompte d t ...

  • SMC Networks SMC9462TX - page 23

    I NSTALL ING AND C ONFI GURING N ETWORK D RIVER S 2-3 Secondary Installation Follo w thi s proce dur e if yo u have alrea dy ins tal led an othe r netw ork card or l oade d an othe r d river. 1. Be su re to i nstall W indows N T Service Packet 4 o r later if it is not already installed. 2. Install the SMC network card (if not already installed ), a ...

  • SMC Networks SMC9462TX - page 24

    I NSTAL LING AND C ONFIGURI NG N ETWORK D RIVE RS 2-4 Further Configuration Y ou can m odify c ard setti ngs, ins tall additi onal proto cols and o ther netwo rk comp onen ts vi a the Windo ws NT “ Net wor k ” applet. 1. Double- c lick on the “ My Co mput er , ” “ Contr ol Panel, ” an d “ Netw ork ” icons. T he “ Network ” dialo ...

  • SMC Networks SMC9462TX - page 25

    I NSTALL ING AND C ONFI GURING N ETWORK D RIVER S 2-5 Windows 2000 Insta llation The EZ Card 10 00 dr ive r for Wind ows 2000 confo rm s to the Network Dr iver Inte rface Specifi cation (NDIS) 5. 0 and can be found in the “ Win ntWin2 000 ” directory on the SMC SuperDisk drive r diske tte. 1. If W indows 200 0 is already inst alled on you r c ...

  • SMC Networks SMC9462TX - page 26

    I NSTAL LING AND C ONFIGURI NG N ETWORK D RIVE RS 2-6 Novell NetWare Installation NetWare Server 5.0 Instal ling the LAN dr iver is part of the NetW are installatio n process. Use the fo llowing i n struct ions with t hose in the NetW are installation manual to inst all the driver . Y ou will need th e SMC SuperDisk during this procedure . Shutdow ...

  • SMC Networks SMC9462TX - page 27

    I NSTALL ING AND C ONFI GURING N ETWORK D RIVER S 2-7 8. A scr een with thre e dialo g boxes i s disp layed. T o change th e driver configu r ation, t ab to the “ SMC9462_1 P aramet ers ” dia log box and modif y the d river p aramet ers. De pending on the network that the car d is attac hed to, the Link, Speed, Du plex Mode, an d Phy Type par a ...

  • SMC Networks SMC9462TX - page 28

    I NSTAL LING AND C ONFIGURI NG N ETWORK D RIVE RS 2-8 NetWare Server 4.11 Instal ling the LAN dr iver is part of the NetW are installatio n process. Use the fo llowing i n struct ions with t hose in the NetW are installation manual to inst all the driver . Y ou will need th e SMC SuperDisk during this proced ure. 1. Shutdown your co mputer an d ins ...

  • SMC Networks SMC9462TX - page 29

    I NSTALL ING AND C ONFI GURING N ETWORK D RIVER S 2-9 9. A scr een with thre e dialo g boxes i s disp layed. T o change th e driver configu r ation, t ab to the “ SMC9462_1 P aramet ers ” dia log box and modif y the d river p aramet ers. De pending on the network that the car d is attac hed to, the Link, Speed, Du plex Mode, an d Phy Type par a ...

  • SMC Networks SMC9462TX - page 30

    I NSTAL LING AND C ONFIGURI NG N ETWORK D RIVE RS 2-10 Linux 2.2. X or Later Installa tion This sectio n desc ribes t he proce dure for manual an d automatic loading and conf iguration of the EZ Card 1000 Uni x stream driv er for Linux 2.2 .X or later . The Lin ux driv er can b e found i n the “ linu x ” direct ory on the SMC Super Disk driver ...

  • SMC Networks SMC9462TX - page 31

    I NSTALL ING AND C ONFI GURING N ETWORK D RIVER S 2-11 RxBufSize: This is the size of the receive buffer memory spac e alloca ted pe r rece ive desc ript or (the labe l given to e ach pa cket receiv ed). The de fault value i s 2048. It should be set at 20 48 to ensure good p erformance wh en not using jumbo f rames. W hen using jumbo frames it shou ...

  • SMC Networks SMC9462TX - page 32

    I NSTAL LING AND C ONFIGURI NG N ETWORK D RIVE RS 2-12 BOOTPROTO=none BROADCAST=207.200.5.255 NETWORK=207.200.5.0 NETMASK=255.255.255.0 IPADDR=207.200.5.2 Automatic Installation This sectio n descri bes how to ins tall the Linux driver so that i t is automat ically l oaded and configured at boot tim e. The following descr iption is bas ed on th e R ...

  • SMC Networks SMC9462TX - page 33

    I NSTALL ING AND C ONFI GURING N ETWORK D RIVER S 2-13 where “ ethx ” will be “ eth0 ” i f you do not h ave any ot her adapters, “ eth1 ” i f you already have one, and so o n. The param eters are the ones di scuss ed in the pr eviou s para graph. 5. Fi nd o ut wh ere the netwo rk co nfig urati on scrip ts are , no rm ally in the “ /et ...

  • SMC Networks SMC9462TX - page 34

    I NSTAL LING AND C ONFIGURI NG N ETWORK D RIVE RS 2-14 Windows 98 Installation The EZ Card 100 0 driver for W indows 98 co nforms to the Netw ork Driver Interface Sp ecificat ion (ND IS) 5.0 and can be fo und in the “ W in98 ” dir ecto ry on the SMC Super Disk driv er di skett e. 1. If Wi ndows 98 is al ready ins talled o n your co mputer , pr ...

  • SMC Networks SMC9462TX - page 35

    I NSTALL ING AND C ONFI GURING N ETWORK D RIVER S 2-15 11. When Wind ows prompts with “ SMC EZ Card 1000 Adapter ” in the “ Add Ne w Hard ware Wi zard ” dialog box, clic k the “ Finis h ” button . 12. Remove the SM C SuperDisk dr iver d iskette from yo ur flop py drive. 13. Restart y our comput er to initializ e the network fu nction . ...

  • SMC Networks SMC9462TX - page 36

    I NSTAL LING AND C ONFIGURI NG N ETWORK D RIVE RS 2-16 Other Installa tions Refe r to the install ation document s on SMC ’ s SuperDisk for instr uctions on inst alling d rivers for us e with ot her op erating systems . Please n ote that n ew release s of SMC driv ers and operati ng systems may re sult i n proc edu res sli ghtly dif fer ent than ...

  • SMC Networks SMC9462TX - page 37

    3-1 C HAPTER 3 C ONFIGURING AND T ESTING THE N ETWORK C ARD Configuration This sectio n desc ribes t he confi g urati on procedure in a W indows envi ronment. Whe n you install the Wi ndows driver , the config uration ut ility is also ins talled. Y ou can run thi s utility by clicki ng on the “ Prop erti es ” button for the card i n the “ Net ...

  • SMC Networks SMC9462TX - page 38

    C ONFIGURING AND T ESTING THE N ETWORK C ARD 3-2 config uration th e switch will sense the link speed bu t will default to half duplex. If t he link pa rtner is conf igured to full d uplex, th e adapter w ill no t con nect co rrec tly re sulti ng in h igh e rror r ates and ineffic ient co m munic ation. T herefore , auto-ne gotiat ion shou ld be di ...

  • SMC Networks SMC9462TX - page 39

    C ONFIGURING AND T ESTING THE N ETWORK C ARD 3-3 Receive Buffer This field l ets you s et the number o f buffers alloc ated in t he memory for use by the ad apter whil e receivi ng packets. Decr easing the nu m ber of buffers reduc es the memory requirement of the adapter . Transmit Buffer This field l ets you s et the number o f buffers alloc ated ...

  • SMC Networks SMC9462TX - page 40

    C ONFIGURING AND T ESTING THE N ETWORK C ARD 3-4 ...

  • SMC Networks SMC9462TX - page 41

    A-1 A PPENDIX A T ROUBLESHOOTING PCI Compatibility Early PCI B IOS vers ion s do no t prop erly supp ort the PCI specific ation and m ay “ hang ” whe n a netwo rk card dr iver tri es to load. If this occurs , make s ure your BIOS co rrectly supports the PCI Local B us Specificat ion (v2.2 or later) an d upgrade y our computer BIOS t o the late ...

  • SMC Networks SMC9462TX - page 42

    T R OUBLESHOOTI NG A-2 ◆ Make s ure th e PCI s lot is config ured to supp ort INT A. ◆ Ensure that INTA for the slot is assigne d to a free in terrupt (IRQ) numbe r. ◆ Check th e BIOS Setup prog ram ’ s PCI par amete rs for the slot where t he EZ Car d 1000 n etwork car d is ins talled. En sure the slot is co nf igur ed for l eve l-trig ge ...

  • SMC Networks SMC9462TX - page 43

    T R OU BLE SHOO TI NG A-3 Solutions for Common Problems Prob lems are of ten c aused by ca bling error s, c onfl icts wit h oth er devi ces inst alled in the same comp uter , or softwar e that h as been config ured inc orrectly . If y ou encou nter a pr oblem wi th the EZ Card 1000 netwo rk card, use the follo wing checkli s ts to identify an d cor ...

  • SMC Networks SMC9462TX - page 44

    T R OUBLESHOOTI NG A-4 Network Connection Problems If you r comput er cann ot find t he EZ Card 1 000 card or t he network driver does not instal l correctl y, check the following items be fore contacti ng SMC Technical Supp ort. ◆ Make su re the card is se curely seated in t he PCI s lot. C heck for any hard ware probl ems, su ch as physic al da ...

  • SMC Networks SMC9462TX - page 45

    B-1 A PPENDIX B C ABLES Cable Specifications Twisted-Pair Cable and Pin Assignments Caution: DO NOT pl ug a phone ja ck connec tor into any RJ -45 port. U se on ly twis ted-pai r cabl es with RJ-45 connect ors that confor m with FCC standards . For 10BASE-T/100BASE-TX connections, a twisted-pair cable must have two pa irs of w ires. Eac h wire pair ...

  • SMC Networks SMC9462TX - page 46

    C ABLES B-2 Caution: Each wir e pair must be at tached to the RJ-4 5 conn ectors in a specifi c orientati on. Figur e B-1 i llustr ates how the pins on the RJ -45 connect or are numb ered . Be su re to hold th e con nec tors i n the same or ient ati on when at taching the w ires to th e pin s. Figure B-1. RJ-45 Connector Pin Numbers ...

  • SMC Networks SMC9462TX - page 47

    C ABLE S B-3 10BASE-T/100BASE-TX Pin Assignments With 10BASE -T/1 00B ASE-T X cabl e, pin s 1 and 2 a re us ed for trans mitting data , and pins 3 and 6 for recei ving data. Th e “ + ” and “ - ” si gns in the tables below ar e used t o repr esent the polarity of the wire s that make up each wire pair . 1000BASE-T Pin Assignments The t able ...

  • SMC Networks SMC9462TX - page 48

    C ABLES B-4 ...

  • SMC Networks SMC9462TX - page 49

    C-1 A PPENDIX C S PECIFICATIONS Bus Inter face 32-bit and 64-b it bus master , PCI Interrupt INT A Network Inter face 1000 BASE-T: UTP cabl e; Category 5, 5e or better 100BASE- TX: UTP cabl e; Category 5 10BAS E-T : UTP cabl e; Category 3, 4, or 5 Data Rate 1000 Mb ps, 100 Mbp s, 10 Mb ps half and full dupl ex Cabling 4 pa irs of C ategor y 5, 5e o ...

  • SMC Networks SMC9462TX - page 50

    S PECI FIC ATION S C-2 We i g h t 2.8 o z (80g ) Te m p e r a t u r e Operating 32 to 14 0 ° F (0 to 60 ° C) Storage - 40 to 18 ° F (-22 to 85 ° C) Humidity 5 to 9 5% (non- condensing ) Standar ds IEEE 8 02. 3ab 10 00BA SE-T IEEE 8 02. 3u 100B ASE -TX IEEE 80 2.3 10BASE-T IEEE 8 02. 3x Ful l-Dup lex f low co ntro l PCI v2.2 Compliances CE Mar k ...

  • SMC Networks SMC9462TX - page 51

    S PECIFICATIO NS C-3 Software Drivers ODI Drivers NetWare Ser ver 4.11 or later NDIS Dr ivers Windows NT 4.0 Windows 98 Windows ME Windows 2000 Unix Drivers Linux 2.2.X or late r ...

  • SMC Networks SMC9462TX - page 52

    S PECI FIC ATION S C-4 ...

  • SMC Networks SMC9462TX - page 53

    Glossary-1 G LOSSARY 10BAS E-T IEEE 80 2.3 specificat ion for 1 0 Mbps Et hernet ov er two pair s of Cate gory 3, 4, or 5 UT P cabl e. 100BASE-TX IEEE 80 2.3u specificat ion for 1 00 Mbps F ast Eth ernet over t wo pairs of Cate gory 5 UTP cable . 1000BAS E-T IEEE 80 2.3ab specifi c ation fo r Gigabit Et hernet over four pai r s of Categ ory 5 UTP c ...

  • SMC Networks SMC9462TX - page 54

    Glossary-2 End Station A works tation, server , switch, bridge or rou ter . Ethernet A net work com municati on system develope d and stand ardized by DEC, Int el, and Xero x, us ing ba seband tr ansmissi on, CSM A/CD acces s, logi cal b us topolo gy, and coaxi al cable. T he suc cessor I EEE 802.3 s tandard p rovides f or integ ration int o the OS ...

  • SMC Networks SMC9462TX - page 55

    Glossary-3 IEEE 802.3 Defines carrie r sens e multip le acce ss with collis ion det ection (CSMA/CD) access method and physical layer specification s. IEEE 802.3u Defines CSMA/CD acce ss method and physical laye r specific ations for 100 BASE-TX Fas t Ethernet. IEEE 802.3ab Defines CSMA/CD acce ss method and physical laye r specific ations for 10 0 ...

  • SMC Networks SMC9462TX - page 56

    Glossary-4 Network Dia meter Wire distance between tw o end stations in the same colli sion domai n. Switched Ports Ports t hat are on separa te colli sion dom ains or LA N segment s. Transmission Control Protocol/Internet Prot ocol (TCP/IP) Proto col sui te that in clude s TCP as t he prim ary trans port pr otocol , and IP as the ne two rk la yer ...

  • SMC Networks SMC9462TX - page 57

    Index-1 A Auto-Negotiation 2-2 B BIOS requirements 1-5 , A-1 bus-mastering 1-5 , A-1 C cable adjusting Category 5 cable 1-8 guidelines 1-7 RJ-45 pin assignments B-3 specifications B-1 card installation 1-5 Category 5 cable 1-8 checklist of contents 1-4 compli ance s i configuration Linux 2-10 Windows 98 2-14 Windows NT 2-4 connection guidelines 1-7 ...

  • SMC Networks SMC9462TX - page 58

    I NDEX Index-2 N NetWare Installation 2-6 NetWar e Serv er 5.0 2-6 network status LEDs 1-3 P package contents 1-4 PC requirements 1-5 PCI bus specification 1-5 compatibility A-1 configuration 1-7 pin assignments B-1 R RELEASE.TXT file 1-7 requirements of system 1-5 RJ-45 connector 1-2 , B-2 RJ-45 po rts pinouts B-3 S specifications cable B-1 static ...

  • SMC Networks SMC9462TX - page 59

    ...

  • SMC Networks SMC9462TX - page 60

    6 Hughes Irvine, C A 9261 8 Phone: (949 ) 707-240 0 FOR TECHNICAL SUPPOR T , CALL: From U. S.A. an d Ca nada (8 :30 A M - 8 :00 PM Pacific Time) (800) SMC-4-YOU; (94 9) 707-240 0; (949) 707-2 460 (Fax) From Europe (8:00 AM - 5:30 PM UK Greenwich Mean T ime) 44 (0) 1189 7487 40; 44 (0) 11 89 74874 1 (Fax) INTERNET E-mail a ddresses: techsupp ort@smc ...

  • SMC Networks SMC9462TX - page 61

    6 Hughes Irvine, C A 9261 8 Phone: (949 ) 707-240 0 ...

  • SMC Networks SMC9462TX - page 62

    -6 ...

メーカー SMC Networks カテゴリー Network Card

SMC Networks SMC9462TXのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SMC9462TXの取扱説明書
- SMC Networksの製品カード
- パンフレット
- またはSMC Networks SMC9462TXの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、SMC Networks SMC9462TXの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、SMC Networks SMC9462TXの取り付け説明書、サービスマニュアル、簡易説明書、またはSMC Networks SMC9462TXのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、SMC Networks SMC9462TXの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

SMC Networks SMC9462TXデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSMC Networks SMC9462TXを使用するのを助ける技術的文書のことです。説明書は通常、全てのSMC Networks SMC9462TXユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

SMC Networksの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. SMC Networks SMC9462TXの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSMC Networks SMC9462TXの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。SMC Networks SMC9462TXに関してこのドキュメントで見つけることができる全てのヒントの目次
3. SMC Networks SMC9462TXデバイスの基本機能を使うにあたってのヒント。 SMC Networks SMC9462TXのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。SMC Networks SMC9462TXに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSMC Networks SMC9462TXのメーカー/サービスへの連絡先に関する情報。

SMC Networks SMC9462TXについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSMC Networks SMC9462TXの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSMC Networks SMC9462TXで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)