York AVY24 THRU 60の取扱説明書

10ページ 0.26 mb
ダウンロード

ページに移動 of 10

Summary
  • York AVY24 THRU 60 - page 1

    TECHNICAL GUIDE SINGLE PIECE V ARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT -SYSTEM COOLING & HEA T P UMPS MODELS: A VY24 THRU 60 AND SV Y48 THRU 60 Due to continuou s produc t improv e m en t, specifications are subject to ch an ge without notice. Visit us on the web at www . york.com Additional rating in formation can be foun d at www .ahrid ...

  • York AVY24 THRU 60 - page 2

    2 Johnson Controls Unitary Products 256819-YTG-J-12 08 DIMENSIONS 10-3/8” F CIRCUIT BREAKER P ANEL BOTTOM INLET DIMENSIONS DRAIN P AN CONNECTIONS FOR HORIZONT AL APPLICA TIONS BLOWER COMP ARTMENT REFRIGERANT CONNECTIONS DRAIN CONNECTIONS FOR UPFLOW AND DOWNFLOW APPLICA TIONS 7-1 1/32” D B A C 1-1/2” E TOP OUTLET DIMENSIONS FIL TER ACCESS 18-9 ...

  • York AVY24 THRU 60 - page 3

    Johnson Controls Unitary Pro ducts 3 256819-YTG-J-1208 COIL TECHNICAL DA T A Models Application Refrig. Conn. T ypes Face Area (Sq. Ft.) Rows Deep Fin Per In. Coil Size Tu b e Geometry Tu b e Dia. Fin Ty p e TXV AV Y 2 4 B 3 X H 2 1 Cooling / Heat Pump Sweat 3.89 2 14 (2) 16 x 17.5 1 x 0.866 3/8 Enhanced None AV Y 2 4 B 2 A H 2 1 2A AV Y 2 4 B 4 E ...

  • York AVY24 THRU 60 - page 4

    4 Johnson Controls Unitary Products 256819-YTG-J-12 08 Air Handler Air Flow Dat a HIGH / LOW SPEED COOLING AND HEA T PUMP AIRFLOW CFM JUMPER SETTINGS 24B 36C High Low High Low COOL T ap ADJ T ap 1088 707 1387 905 A B 830 542 1 151 753 B B 948 617 1201 783 A A 716 465 1009 657 B A 854 556 1086 703 A C 612 462 953 622 C B 637 460 901 588 B C 531 460 ...

  • York AVY24 THRU 60 - page 5

    Johnson Controls Unitary Pro ducts 5 256819-YTG-J-1208 APPLICA TION F ACTORS - RA TED CFM VS. ACTUAL CFM % Of Rated Airflow 80% 90% Rated CFM 1 10% 120% Capacity Factor 0.96 0.98 1.00 1.02 1.03 PHYSICAL & ELECTRICAL DA T A - COOLING ONL Y (60 Hz) Models A VY24B**H21 A VY36C**H21 AV Y 4 8 D * * H 2 1 SVY48D**N21 AV Y 6 0 D * * H 2 1 SVY60D**N21 ...

  • York AVY24 THRU 60 - page 6

    6 Johnson Controls Unitary Products 256819-YTG-J-12 08 * May be 0 (no breaker) or 1 ( with breaker). ELECTRICAL DA T A - 208/230-1-60 Models Heat Kits* Max. Stat i c Min. Spee d T ap To ta l H e a t 1 kW S taging KW MBH W1 Only W2 Only W1 & W2 208v 230v 208v 230v 208v 230v 208v 230v 208v 230v A VY24B**H21 4HK*6500206 0.5 Heat-D 1.9 2.5 6.4 8.5 ...

  • York AVY24 THRU 60 - page 7

    Johnson Controls Unitary Pro ducts 7 256819-YTG-J-1208 * May be 0 (no breaker ) or 1 (with breaker). ELECTRICAL DA T A (FOR SINGLE SOURCE POWER SUPPL Y) - COPPER WIRE 208/230-1-60 Models Heat Kit - Single Phase* Heater Amps 240V Field W iring Min. Circuit Ampacity Max. O.C.P . Amp s/T ype 1 75 ° C W ire Size - A WG 208V 230V 208V 230V 208V 230V A ...

  • York AVY24 THRU 60 - page 8

    8 Johnson Controls Unitary Products 256819-YTG-J-12 08 ELECTRICAL DA T A - 208/230-3-60 Models Heat Kit - Three Phase Max. Static Min. Speed Ta p T otal Heat 1 KW St aging KW MBH W1 Only W2 Only W1 + W2 208V 230V 208V 2 30V 208V 230V 208V 2 30V 208V 230V A VY24B**H21 4HK06501025 0.5 Heat-B 7.2 9.6 24.6 32.8 7.2 9.6 7.2 9.6 7.2 9.6 A VY36C**H21 4HK0 ...

  • York AVY24 THRU 60 - page 9

    Johnson Controls Unitary Pro ducts 9 256819-YTG-J-1208 ACCESSORIES Refer to Price Manual for spec ific model numbers where not shown. TXV Kits - TXV kits are available for “Flex-coil” applications and converting R-22 to R-410A or as a service replacement. Al l kits are bolt-on and require no brazing to install. Electric Heaters - 4HK models sho ...

  • York AVY24 THRU 60 - page 10

    Subject to change without notice. Printe d in U.S.A. 256819-YTG-J-1208 Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: 256819-YTG-I-0808 Johnson Controls Unitary Product s 5005 Y o rk Drive Norman, OK 73069 TWO-ST AGE COOLING WIRING * Optional dehumidification humidistat switch contacts open on humidity rise. NOTES : 1. ...

メーカー York カテゴリー Air Conditioner

York AVY24 THRU 60のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AVY24 THRU 60の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork AVY24 THRU 60の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York AVY24 THRU 60の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York AVY24 THRU 60の取り付け説明書、サービスマニュアル、簡易説明書、またはYork AVY24 THRU 60のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York AVY24 THRU 60の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York AVY24 THRU 60デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork AVY24 THRU 60を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork AVY24 THRU 60ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York AVY24 THRU 60の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork AVY24 THRU 60の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York AVY24 THRU 60に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York AVY24 THRU 60デバイスの基本機能を使うにあたってのヒント。 York AVY24 THRU 60のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York AVY24 THRU 60に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork AVY24 THRU 60のメーカー/サービスへの連絡先に関する情報。

York AVY24 THRU 60についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork AVY24 THRU 60の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork AVY24 THRU 60で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)