Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72の取扱説明書

20ページ 0.81 mb
ダウンロード

ページに移動 of 20

Summary
  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 1

    SERVICE MANUAL For additional information on Vulcan-Hart or to locate an authorized parts and service provider in your area, visit our website at www.vulcanhart.com F35628 (10-04) - NOTICE - This manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified. If you have attended a Vulcan ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 2

    — 2 — F35628 (10-04) T ABLE OF CONTENTS GENERAL ............................................................................................................................... ......... 3 Introduction ............................................................................................................................... .3 Installation . ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 3

    — 3 — F35628 (10-04) INTRODUCTION Procedures in this manual will apply to all models unless specified. Pictures and illustrations can be of any model unless the picture or illustration needs to be model specific. All models are equipped with 30,000 BTU/HR burners as standard equipment. One burner is used for every 12 inches of griddle surface. ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 4

    — 4 — F35628 (10-04) REMOV AL AND REPLACEMENT OF P ARTS COMPONENT LOCATION Figure A Bullnose Deflector Plate Heat Shield Control Plate Control Panel Grease Drawer Griddle Flame Switch Ignitor Module Dual Solenoid Pilot Solenoid Dual Solenoid Ignitor Module Panel Connector Flame Switch Back Panel ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 5

    — 5 — F35628 (10-04) CONTROL PANEL WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the two screws securing the control panel. One screw is located at each end of the control panel. 2 . Pull the control panel forward and disconnect the electrical connector near the right end. Figure B 3. ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 6

    — 6 — F35628 (10-04) POWER ON/OFF SWITCH WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the control panel. 2. Label and disconnect the wires to the power ON/OFF switch. 3. Squeeze the switch retainer and slide the switch out through the front of the control panel. Figure E 4. Reverse pr ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 7

    — 7 — F35628 (10-04) FLAME SWITCH WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the control panel. 2. Label and disconnect the wires to the flame switch. 3. Remove the two screws securing flame switch to control plate. 4. Remove sensor from the pilot assembly. Sensor can be accessed fr ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 8

    — 8 — F35628 (10-04) GAS BURNER WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the back panel. 2. Cut shipping tie from burner. 3. To remove the burner, reach through the back of the unit and lift the burner up over the guide screw then pull the burner out through the back of the unit. ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 9

    — 9 — F35628 (10-04) PILOT WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. WARNING: SHUT OFF THE GAS BEFORE SERVICING THE GRIDDLE. 1. Remove control panel and heat shield for visual access of the pilot. 2. Reaching underneath the front of the griddle remove the pilot tube fitting and disengage the ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 10

    — 10 — F35628 (10-04) WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TEST OR MEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER AND FOLLOW LOCKOUT / TAGOUT PROCEDURES, ATTACH TEST EQUIPMENT AND REAPPLY POWER TO TEST. THERMOSTAT CAL ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 11

    — 11 — F35628 (10-04) 2. Units for operation of natural or propane gas are also equipped with a factory preset pressure regulator with an outlet pressure of 5” W.C. (Water Column) for natural gas supply and 10” W.C. for propane gas supply, and should not require further adjustment. 3. The burners and pilot flames may be observed through rou ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 12

    — 12 — F35628 (10-04) COMPONENT DESCRIPTION Power Switch ON/OFF – Switch turns power ON or OFF. Ignition Control Module – Provides ignition spark. Turned on when ON/OFF switch is set to the ON position and turned off when flame switch closes. Burner On Lights – Illuminates to indicate burner is turned on. Thermostats – Turns burner on a ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 13

    — 13 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 24” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2. HARNESS PART NO. 723526-1 ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 14

    — 14 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 36” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2. HARNESS PART NO. 723527-1 ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 15

    — 15 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 48” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2. HARNESS PART NO. 723528-1 ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 16

    — 16 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 60” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2. HARNESS PART NO. 723529-1 ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 17

    — 17 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 72” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2. HARNESS PART NO. 723530-1 ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 18

    — 18 — F35628 (10-04) TROUBLESHOOTING GUIDE SYMPTOM Indicator light fails to light when power ON/OFF switch is set to ON position Indicator light fails to go out when power ON/OFF switch is set to the OFF position Griddle does not heat when thermostat is turned on Igniter stays on too long after pilot flame is established Igniter fails to light ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 19

    — 19 — F35628 (10-04) TROUBLESHOOTING GUIDE REMEDY Check operation of pilot valve Purge gas lines Check that gas supply is on Check and repair wire connection Check for obstruction or wrong size orifice Realign pilot and igniter Check and repair wire connection Correct air flow Check for obstruction or wrong size orifice Realign pilot and ignit ...

  • Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - page 20

    FORM 35628 (10-04) PRINTED IN U.S.A. ...

メーカー Vulcan-Hart カテゴリー Griddle

Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE MLの取扱説明書
- Vulcan-Hartの製品カード
- パンフレット
- またはVulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72の取り付け説明書、サービスマニュアル、簡易説明書、またはVulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがVulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72を使用するのを助ける技術的文書のことです。説明書は通常、全てのVulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Vulcan-Hartの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははVulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72デバイスの基本機能を使うにあたってのヒント。 Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるVulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72のメーカー/サービスへの連絡先に関する情報。

Vulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもVulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがVulcan-Hart 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)