Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceの取扱説明書

18ページ 1.27 mb
ダウンロード

ページに移動 of 18

Summary
  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 1

    Report No. 317-S-05-5 IN ST AL LA TI ON AN D OP ER A TIO N IN ST RU CT IO NS Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do not light any appliance. • Do not touch any electrical switches; do not use any phone in your building. • Immediately ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 2

    2 1. 0 I MP OR T AN T SA F ET Y AN D W ARN I NG IN F OR MA T IO N W ARNINGS If th e info rma tio n in this manu al is not fol- low ed e xac tly , a fi re or exp los ion may res ult cau sin g pro per ty dama ge, pers ona l inj ury or los s o f li fe. IMPOR T ANT Rea d and un der stan d the se ins tru ctio ns com ple tel y bef ore inst alli ng or op ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 3

    3 2.0 GENERAL INFORMA TION This appliance is a high efficiency , unvented, flame effect gas heater . It provides radiant and convected warmth both efficiently and safely utilizing the latest type catalytic convertor burner technology . The appliance does not require a flue system of any type as the catalytic converter cleans the flue products ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 4

    4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE THE FOLLOWING BOXED INFORMA TION APPLIES TO REQUIRE- MENTS FOR THE COMMONWEAL TH OF MASSACHUSETTS. Note: The following requirements reference various Massachusetts and national codes not contained in this document. Unvented Room Heaters shall be installed in accordance with 527 CMR 30.00 and 24 ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 5

    5 7.0 COMBUSTION AND VENTILA TION AIR This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventil ation air . The heater may be located in unusually tight construction provided the space is unconfined, or if confined, is provided with two permanent openi ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 6

    6 8.0 SITE REQUIREMENTS This appliance is designed to be wall-hung. Do not recess any part of the appliance into the wall. This appliance may be installed in any room in a home except bedrooms or bathrooms - or areas where large amounts of steam are likely to be generated. It should be noted that heaters create warm air currents. These currents mov ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 7

    7 After having selected the final mounting position of the appliance, taking into account the site requirem ents as specifie d in Section 8 of these instr uc- tions, the integrity of the wall, and the feasibility of the proposed supply pipe routing, the firebox of appliance may be secured to the wall. T o ensure customer safety , be sure to desi ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 8

    8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE Insert the wall mounting screws into the top wall plugs, taking care to leave the screws protruding approximately 3/8” from the wall. Now hang the appliance onto these screws through the two keyhole shaped holes in the back panel of the appliance. Insert the lower mounting screws into the low ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 9

    9 13.0 CHECKING THE GAS CONNECTIONS T urn on gas supply and test for gas leaks using a gas leak test solution (also referred to as bubble leak solution). NOTE: using a soapy water solution (50% dish soap, 50% water) is an effective leak test solution, but it is not recommended, because the soap residue that is left on the pipes/fittings can result ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 10

    10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 15.0 SP ARK GAP The gap between the spark electrode and the pilot should be 1/8” to 3/16” to produce a good spark. There should be no need to adjust this. If under any circumstances the piezo electric spark fails, the pilot cannot be lit manually . 16.0 ASSEMBL Y OF THE GLASS FACIA Figure ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 11

    11 5. Secure the grill in position using two M6 screws and two no. 8 self tapping screws as shown in Figure 14 . 17.0 FITTING THE GLASS F ACIA The glass facia panel is supported by four M6 screws which protrude from the front of the outer casing. Insert the M6 retaining screws and ensure they are unscrewed approximately 1/8” so the keyhole shaped ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 12

    12 19.0 BRIEFING THE CUSTOMER W ARNING Do not add log s or orn amen ts such as pine con es, ver mic uli te or roc k woo l. Usi ng the se add ed ite ms can ca use soo tin g. All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire. Show the customer how to remove and replace the glass facia. A ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 13

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE 13 Clean the pilot assembly with a soft brush and blow through. Check the aeration holes are free of any dirt or lint. Clean thoroughly internally , the connection can be removed from the base of the pilot unit using two spanners to make cleaning easier . Do not damage or try to dismantle the pil ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 14

    14 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lit with a piezo spark igniter . When lighting the pilot, follow these instructions exactly . B. BEFORE OPERA TING ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 15

    15 27.0 TROUBLESHOOTING GUIDE PROBLEM CORRECTIVE ACTION Igniter sparks but pilot does not light • No gas to Pilot, check the gas line connections. • Air not fully purged. Purge supply or wait longer . • Spark grounding to metal work, reset gap correctly . • Blocked pilot, clean out internally . Pilot lights but then goes out • Severe rest ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 16

    16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE Figure 22 Figure 21 29.0 POSITIONING OF FIELD REMOV ABLE P ARTS W ARNING Fai lur e to pos itio n the part s in acc orda nce with the se diag rams or fail ure to use only part s sp ecifi cal ly appr ove d wit h t his hea ter ma y re sul t i n p rop ert y da mag e o r pe rso nal inj ury . Visua ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 17

    17 30.0 NOTES ...

  • Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlace - page 18

    18 Printed in U.S.A. © Lennox Hearth Products 2007 P/N 850,055M REV . A 12/2007 Lennox™ reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. 1110 West T aft Avenue • Orang ...

メーカー Lennox Hearth カテゴリー Electric Heater

Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- Catalytic Vent-Free Wall Mounted Gas FirePlaceの取扱説明書
- Lennox Hearthの製品カード
- パンフレット
- またはLennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceの取り付け説明書、サービスマニュアル、簡易説明書、またはLennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceを使用するのを助ける技術的文書のことです。説明書は通常、全てのLennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lennox Hearthの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceデバイスの基本機能を使うにあたってのヒント。 Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceのメーカー/サービスへの連絡先に関する情報。

Lennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLennox Hearth Catalytic Vent-Free Wall Mounted Gas FirePlaceで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)