    06786-04/12/22 Installer Manual VENTILA TION SYSTEMS Model Numbers HR V -150 HR V -210 ER V -150 ER V -210 VB0066 ...

  • Maytag ERV-150 - page 2

    2 T able of Contents 1.0 S ERVICE ............................................................................................4 1.1 3-D Drawing ................................................................................4 1.2 Parts Ordering Chart ....................................................................5 1.3 T echnical Support ...... ...

  • Maytag ERV-150 - page 3

    3 T able of Contents (cont’d) About this Manual 8.0 I NST ALLA TION OF THE C ONTROLS ..................................................22 8.1 Dimensions and Specifications ................................................22 8.2 Installation of the Main Control ..........................................22-23 8.3 Electrical Connection to Optional Co ...

  • Maytag ERV-150 - page 4

    4 1.1 3-D D RA WING 1.0 Service 6 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 3 21 21 22 23 24 VL0018 25 D AMPER ASSEMBL Y ( REAR VIEW ) ...

  • Maytag ERV-150 - page 5

    5 tel: 1-866-2MA YT AG No Description 150 150 210 210 HRV ER V HRV ERV 1 Double collar port #2 00866 00866 00866 00866 2 Wing nut #10-32 00874 00874 00874 00874 3 Balancing double collar port 02256 02256 02256 02256 4 Inlet ring 12913 12913 12913 12913 5 Motor assembly 13504 13555 13556 13506 6 Electronic board V99 13507 13507 13507 13507 7 Square ...

  • Maytag ERV-150 - page 6

    6 2.0 Sizing These are the two most common methods used to evaluate the ventilation needs of a house: CSA F326 and Canadian Building Code: • High speed: 10 cfm per room 20 cfm for the master bedroom and the basement • Low speed: 40-60% of high speed ASHRAE Standard 62-2001: • 0.35 air change per hour Refer to ventilation code of your area to ...

  • Maytag ERV-150 - page 7

    ANCHORAGE WHITEHORSE JUNEAU HAY RIVER YELLOWKNIFE Prince Rupert GRANDE PRAIRIE FORT MCMURRAY ZONE A FORT SMIT H EDMONTON PRINCE ALBERT SASKATOON JASPER KAMLOOP S CALGARY PENTICTON REGIN A LETHBRIDGE HELEN A VICTORIA OLYMPIA WINNIPEG SALEM BOISE BISMARCK SALT LAKE CITY SAULT STE MARIE ST. PAUL DES MOINE S MADISON TIMMINS HARRISBURG SACRAMENTO DENVE ...

  • Maytag ERV-150 - page 8

    8 Applicable to all model numbers. Defrost Mode 1 Applicable to model numbers: • HRV -150 • HRV -210 Defrost Mode 2 Applicable to model numbers: • ERV -150 • ERV -210 4.1 A IR D ISTRIBUTION (N ORMAL O PERA TION ) 4.2 A IR D ISTRIBUTION (D EFROST M ODE ) 4.0 T echnical Data VF0013 FRESH AIR FROM OUTSIDE ST ALE AIR FROM BUILDING ST ALE AIR TO ...

  • Maytag ERV-150 - page 9

    9 MODEL NUMBER: ER V -150 Electrical requirements: 120 volts, 1.3 Amps Exhaust Air T ransfer Ratio: 0.06 4.3 P ERFORMANCE C HARTS 4.0 T echnical Data (cont’d) VENTILA TION PERFORMANCE External Static Net Supply Gross Air Flow Pressur e Air Flow Supply Exhaust Pa in. w .g. l/s cfm l/s cfm l/s cfm 25 0.1 81 173 87 184 93 197 50 0.2 78 165 83 175 86 ...

  • Maytag ERV-150 - page 10

    ENERGY PERFORMANCE Supply Net A verage Sensible Recovery Apparent Sensible Latent Recovery T emperature Airflow Power Efficiency Effectiveness Moisture T ransfer °C °F l/s cfm W atts % % 0 32 51 109 92 70 77 -0.01 0 32 73 155 128 65 72 -0.02 0 32 102 215 191 62 70 -0.01 -25 -13 52 1 10 104 60 94 0.05 T otal Recovery Efficiency 35 95 Not tested EN ...

  • Maytag ERV-150 - page 11

    11 Model numbers: • ERV -150 • HRV -150 Model numbers: • ERV -210 • HRV -210 13-3/4" ( 349mm ) 20" (508mm) ( 5 0 0 " 6" ( 152mm ) 2.5" ( 63mm ) 30-1/4" ( 768mm ) VK 00 4 0 4.4 D IMENSIONS 4.0 T echnical Data (cont’d) 19" ( 483mm ) 20" (508mm) 0 8 m ( 5 0 6" ( 152mm ) 30-1/4" ( 768mm ) 2.5& ...

  • Maytag ERV-150 - page 12

    12 5.0 T ypical Installation (Primarily for homes with radiant hot water or electric baseboard heating. See figure 1.) Moist, stale air is exhausted from the high humidity areas in the home, such as bathrooms, kitchen and laundry room. Fresh air is supplied to bedrooms and principal living areas. The use of bathroom fans and a range hood is suggest ...

  • Maytag ERV-150 - page 13

    13 6.0 Installation 6.1 A DJUSTING THE D AMPER R OD (F OR ERV S I NST ALLED IN W ARM R EGIONS ) Refer to Section 4.2 and observe the difference in the damper position at the right in diagrams Defrost Mode 1 and Defrost Mode 2: for Defrost Mode 1 the damper is completely closed, whereas for Defrost Mode 2 the damper is half closed. At the factory , ...

  • Maytag ERV-150 - page 14

    14 6.0 Installation (cont’d) a) Follow the instructions in Section 6.4 below to determine the appropriate duct diameters for your system. b) Keep it simple. Plan for a minimum number of bends and joints. Keep the length of insulated duct to a minimum. c) Do not use wall cavities as ducts. Do not use branch lines smaller than 4” (102 mm) Ø. d) ...

  • Maytag ERV-150 - page 15

    15 6.0 Installation (cont’d) 6.4.2 Example of a design for a fully ducted system for a unit having a high speed performance of 222 cfm (See figure 9) . VI0004 4” Ø 42 cfm 6” Ø 129 cfm 5” Ø 65 cfm 5” Ø 64 cfm 6” Ø 93 cfm 5” 6” 7” 7” 6” 6” 6” 4” 4” 4” 4” 7” Ø 222 cfm 7” Ø 222 cfm 4” Ø 42 cfm 6” Ø 84 ...

  • Maytag ERV-150 - page 16

    6.5.2 Exhaust Ducted System (Source Point V entilation) (as illustrated in Section 5.2) Stale air exhaust ductwork: (same as for Fully Ducted System, described on page 15) Fresh air distribution: There are two methods for connecting the unit to the furnace: Method 1: supply side connection • Cut an opening into the furnace supply duct at least 18 ...

  • Maytag ERV-150 - page 17

    6.5.3 Simplified installation (V olume V entilation) (as illustrated in Section 5.3) There are two methods (figures 12 and 13) for connecting the unit to the furnace: Method 1: return-supply Method 2: return-return Stale air intake: • Cut an opening into the furnace return duct (not less than 10 feet (3.1 m) from the furnace (A+B)). • Connect t ...

  • Maytag ERV-150 - page 18

    18 6.0 Installation (cont’d) Insulated flexible duct Use the following procedure for connecting the insulated flexible duct to the ports on the unit (exhaust to outside and fresh air from outside). a) Pull back the insulation to expose the flexible duct. b) Connect the interior flexible duct to the port using a duct tie. c) Carefully seal the con ...

  • Maytag ERV-150 - page 19

    19 6.7 I NST ALLING THE E XTERIOR H OODS 6.0 Installation (cont’d) Choose an appropriate location for installing the exterior hoods: • a minimum distance of 6 feet (1.8 m) between the hoods to avoid cross-contamination • a minimum distance of 18 inches (457 mm) from the ground Make sure the intake hood is at least 6 feet (1.8 m) away from any ...

  • Maytag ERV-150 - page 20

    20 Basic model 7.1 Main Contr ols 7.0 Contr ol Devices CO NDEN S AT I 0 N CO NTR O L AIR SUPPL Y CONTRO L L L MIN. MAX. O F F A AI R R I I EXCHANGE CH HA -2 0 C - 4 ° 41 ° F C O F Z N E S U M M E R VC0027 Electronic model ° C - 4 ° F - 5 C 41 ° F CO NDEN S AT I 0 N CO NTR O L AIR SUPPL Y CONTRO L L L CO NDEN SA T I O N CO NTR OL MAXIM U M S PE ...

  • Maytag ERV-150 - page 21

    21 7.0 Contr ol Devices (cont’d) 7.4 M AIN AND O PTIONAL C ONTROLS A V AILABLE FOR YOUR U NIT MAIN CONTROLS OPTIONAL CONTROL Model number BASIC ELECTRONIC 20/40/60-min. push-button timer Furnace Interlock ERV -150 X X X Integrated HRV -150 X X X Integrated ERV -210 X X X Integrated HRV -210 X X X Integrated 7.5 S PECIAL C OLD W EA THER TBI M ODE ...

  • Maytag ERV-150 - page 22

    22 8.0 Installation of the Contr ols V oltage: 12 volts DC Dimensions: 5” x 5” x 1 3/8” (127 mm x 127 mm x 35 mm) INSTRUCTIONS: 1- Determine the location of the control. The wall control must be installed in a central location on t he main floor . T ypical locations for these controls are kitchen, main hallways and family room. 2- Remove the ...

  • Maytag ERV-150 - page 23

    23 8.0 Installation of the Contr ols (cont’d) 4- Connect the wires to the main control. (See figure 17.) 5- Make sure the instruction pull-out is in the occupant’s language. If not, turn it to the other side. (See figure 18.) 6- Reinstall the cover plate and the button(s). 7- Connect the wires to their corresponding position inside the electric ...

  • Maytag ERV-150 - page 24

    24 8.0 Installation of the Contr ols (con’d) W R G Y W R G C Y 9 8 7 6 5 4 3 2 1 HRV CONTROL CONNECTOR THERMOSTAT TERMINALS FOUR WIRES I OC OL Y R G B F F J3 TWO WIRES heating only FURNACE 24-VOLT TERMINAL BLOCK TWO WIRES COOLING SYSTEM VE0010A Standard furnace interlock wiring 8.3 E LECTRICAL C ONNECTION TO O PTIONAL C ONTROLS 9 8 7 6 5 4 3 2 1 ...

  • Maytag ERV-150 - page 25

    25 9.0 Wiring Diagram A1 M1 M2 K1 RELAY K2 RELAY K5 RELAY FAN MOTOR DAMPER MOTOR NEUTRAL MED NC HIGH LOW J1 6 J1 3 J1 4 J1 9 K4 RELAY J3 1 J3 2 FURNACE BLOWER INTERLOCK CLASS 2 CIRCUIT ONLY ELECTRONIC ASSEMBLY S1 120V 60Hz FROM MAIN J1 2 J1 1 J1 8 VE0018A BK G R Y R BK Y NOTE 4 WALL CONTROL WALL CONTROL WALL CONTROL WALL CONTROL OVERRIDE SWITCH OVE ...

  • Maytag ERV-150 - page 26

    26 W HA T YOU N EED T O B ALANCE THE U NIT • A magnehelic gauge capable of measuring 0 to 0.25 inch of water (0 to 62.5 Pa) and 2 plastic tubes. • T wo ”Flow Measuring Stations” or two flow collars (the size will vary depending on the duct diameter). P RELIMINARY S T AGES T O B ALANCE THE U NIT • Seal all the unit ductwork with tape. Clos ...

  • Maytag ERV-150 - page 27

    27 B ALANCING P ROCEDURE 1. Set the unit to high speed . Make sure that the furnace blower is ON if the installation is in any way connected to the ductwork of the cold air return. If not, leave furnace blower OFF . If the outside temperature is below 0°C / 32°F , make sure the unit is not running in defrost while balancing. (By waiting 10 minute ...

  • Maytag ERV-150 - page 28

    28 BASIC (6 different control scenarios to be tested) 1 1.1 M AIN C ONTROLS This procedure allows the installer to verify that all modes of operation are fully functional. During the verification of a main control, make sure that all optional remote controls are inactive. 11.0 Overall V erification Set the slider Set condensation control Results ex ...

  • Maytag ERV-150 - page 29

    29 • Review with the user the steps required for the regular maintenance of her/his ventilation system. These steps are described in details in the user manual: • Warn the user of the necessity to rebalance the system following a major house renovation or following the installation of any extra registers. • Make sure the user understands how ...

  • Maytag ERV-150 - page 30

    30 Problems Possible causes Y ou should try this 1. Unit does not work. • The circuit board may be defective. • Unplug the unit. Disconnect the main control and the optional(s) control(s) (if need be). Jump B and G terminals. Plug the unit. If the motor runs on high speed and the damper opens, the circuit board is not defective. 2. The damper a ...

  • Maytag ERV-150 - page 31

    31 Problems Possible causes Y ou should try this 4 . The 20-minute push-button • The switch or the 20/40/60-minute may be defective. push-button timer does not workOR its indicator light does not stay on. • Unplug the unit. Disconnect the main control and the optional(s) control(s) (if need be). Jump the OL and OC terminals. Plug the unit. If t ...

  • Maytag ERV-150 - page 32

    14.0 W arranty The standard warranty for the HRV or ER V unit is one year parts only . If this product was installed with a matched MA YT AG system, it carries a 10-year parts only warranty . 15.0 References R 2000 C LI S TE D C LI S TE D US • HVI, “Installation Manual for Heat Recovery V entilators”, 1987 edition. • ASHRAE 1984 Systems Han ...

メーカー Maytag カテゴリー Ventilation Hood

Maytag ERV-150のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- ERV-150の取扱説明書
- Maytagの製品カード
- パンフレット
- またはMaytag ERV-150の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Maytag ERV-150の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Maytag ERV-150の取り付け説明書、サービスマニュアル、簡易説明書、またはMaytag ERV-150のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Maytag ERV-150の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Maytag ERV-150デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMaytag ERV-150を使用するのを助ける技術的文書のことです。説明書は通常、全てのMaytag ERV-150ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Maytagの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Maytag ERV-150の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMaytag ERV-150の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Maytag ERV-150に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Maytag ERV-150デバイスの基本機能を使うにあたってのヒント。 Maytag ERV-150のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Maytag ERV-150に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMaytag ERV-150のメーカー/サービスへの連絡先に関する情報。

Maytag ERV-150についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMaytag ERV-150の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMaytag ERV-150で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)