Invacare 3800の取扱説明書

36ページ 1.19 mb
ダウンロード

ページに移動 of 36

Summary
  • Invacare 3800 - page 1

    Owner’s Operation and Maintenance Manual DEALER: This manual MUST be given to the user of the tub. USER: BEFORE using this tub, read this manual and save for future reference. For more information regarding Invacare products, parts, and services, please visit www.invacare-ccg.com Recessed Side Entry Bath Tubs Model 3750 Model 3800 AFTER INSTALLAT ...

  • Invacare 3800 - page 2

    Recessed Side Entry Bath Tubs 2 Part No 1150695  WARNING DO NOT USE THIS PRODUCT OR AN Y AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READ ING AND UNDERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTION AL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MA NUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OP TIONAL EQUIPMENT ...

  • Invacare 3800 - page 3

    TABLE OF CONTENTS Part No 1150695 3 Recessed Side Entry Bath Tubs TABLE OF CONTENTS SPECIAL NOTES ................................................................................ 5 LABEL LOCATION ............................................................................ 6 TYPICAL PRODUCT PARAMETERS ................................................ ...

  • Invacare 3800 - page 4

    TABLE OF CONTENTS Recessed Side Entry Bath Tubs 4 Part No 1150695 TABLE OF CONTENTS Safety Inspection Checklis ts ................... ............................................. .................. .................................29 Initially ..................................................................................... .................. ...

  • Invacare 3800 - page 5

    SPECIAL NOTES Part No 1150695 5 Recessed Side Entry Bath Tubs SPECIAL NOTES Signal  words  are  use d  in  this  manual  and  apply  to  hazards  or  unsafe  practices  which  could  result  in  personal  injury  or  property  damage.  Refer  to  the  following  table ...

  • Invacare 3800 - page 6

    LABEL LOCATION Recessed Side Entry Bath Tubs 6 Part No 1150695 LABEL LOCATION    ? ...

  • Invacare 3800 - page 7

    TYPICAL PRODUCT PARAMETERS Part No 1150695 7 Recessed Side Entry Bath Tubs TYPICAL PRODUCT PARAMETERS 3750 3800 MINIMUM SPACE REQUIREMENTS: 7 feet x 6 feet LENGTH EXTERIOR: INTERIOR: 59½ inches 49 inches 59½ inches 49 inches WIDTH EXTERIOR: INTERIOR (SEAT): 31.5 inches 21 inches 31.5 inches 21 inches DECK HEIGHT: 41.5 inches SIDE ACCESS DOOR: 40- ...

  • Invacare 3800 - page 8

    FEATURES Recessed Side Entry Bath Tubs 8 Part No 1150695 FEATURES 3750 Control Panel Tub Interior Flow Water Therm ometer Tub Exterior Service Access Door Door Door Handle Drain Drain Plug Burp Fitting Whirlpool Jets Control Panel (See Above) Shower ON/ OFF Valve Whirlpool Aerator Valve Water Temperature Control Valve Tub Fill Valve Whirlpool ON/OF ...

  • Invacare 3800 - page 9

    FEATURES Part No 1150695 9 Recessed Side Entry Bath Tubs 3800 Control Panel Tub Interior Flow Water Therm ometer Tub Exterior Service Access Door Door Door Handle Drain Drain Plug Burp Fitting Whirlpool Jets Control Panel (See Above) Shower ON/ OFF Valve Whirlpool Aerator Valve Water Temperature Control Valve Tub Fill Valve Whirlpool ON/OFF Button ...

  • Invacare 3800 - page 10

    SECTION 1—GENERAL GUIDELINES Recessed Side Entry Bath Tubs 10 Part No 1150695 SECTION 1—GENERAL GUIDELINES  WARNING SECTION 1 - GENERAL GUIDELIN ES contains important information for the safe operation and use of this product. Check  all  parts  for  shipping  damage  before  using.  In  case  of  damage,  ...

  • Invacare 3800 - page 11

    SECTION 1—GENERAL GUIDELINES Part No 1150695 11 Recessed Side Entry Bath Tubs Electrical Be  certain  ALL  electrical  wor k  is  performed  by  a  qualified  electrician  and  is  in  compliance  with  local  electrical  codes. ALL  electrical  connections  are  to  be  wa t ...

  • Invacare 3800 - page 12

    SECTION 1—GENERAL GUIDELINES Recessed Side Entry Bath Tubs 12 Part No 1150695 Maintenance and Inspection  DANGER ELECTRICAL SHOCK HAZARD. All disasse mbly and maintenance of the tub MUST be done by a qualif ied technician, certified electrician or plumber. Disconnect electrical supply or turn o ff circuit breaker befo re performing any mainten ...

  • Invacare 3800 - page 13

    SECTION 1—GENERAL GUIDELINES Part No 1150695 13 Recessed Side Entry Bath Tubs Operation  DANGER Keep hair and body away from su ction guard when pump is running. The causes, symptoms, and effects of hyperthermia may be described as follows: Hyperthermia occurs when the internal temperature of the bo dy reaches a level several degrees above the ...

  • Invacare 3800 - page 14

    SECTION 2—PARTS AND INSTALLATION Recessed Side Entry Bath Tubs 14 Part No 1150695 SECTION 2—PARTS AND INSTALLATION Parts Information For  parts  information,  please  contact  ICCG  Te c h n i c a l  Service  at  (800)  668 ‐ 2337. About Installation  WARNING Access for servicing the tub MUST be provid ed. If ...

  • Invacare 3800 - page 15

    SECTION 2—PARTS AND INSTALLATION Part No 1150695 15 Recessed Side Entry Bath Tubs Installing the Tub  WARNING Protective eye wear MUST be worn when dri lling to avoid possible eye injury. The tub MUST be supported by the floor and not the deck. NOTE:  For  this  proced ure,  ref er  to  FIGURE 2.2,  FIGURE 2.3  on  p ...

  • Invacare 3800 - page 16

    SECTION 2—PARTS AND INSTALLATION Recessed Side Entry Bath Tubs 16 Part No 1150695 13. Model  3750  Only ‐ P erform  the  following  steps  to  install  the  shower  wan d: A. Determine  the  mounting  location  for  the  shower  wa n d  and  mark  this  on  the  w all. ? ...

  • Invacare 3800 - page 17

    SECTION 2—PARTS AND INSTALLATION Part No 1150695 17 Recessed Side Entry Bath Tubs Electrical and Plumbing Hook-up Locations on the Tub NOTE:  For  this  proced ure,  ref er  to  FIGURE 2.5  on  page  17. NOTE:  For  installation  deta ils  ref e r  to  Electrical  Installation  on  page 18  ...

  • Invacare 3800 - page 18

    SECTION 2—PARTS AND INSTALLATION Recessed Side Entry Bath Tubs 18 Part No 1150695 Electrical Installation  DANGER When using electrical prod ucts, basic precautions shou ld alw ays be followed, including the following: RISK OF ELECTRIC SHOCK. Connect the b athtub only to a circ uit protected by a ground-fault circuit-interrupter (GFC I). Use a ...

  • Invacare 3800 - page 19

    SECTION 2—PARTS AND INSTALLATION Part No 1150695 19 Recessed Side Entry Bath Tubs 6. Open  the  service  access  panel  to  access  pu mp  electric  connections  (Detail  “ A”). 7. Route  electrical  line  through  electrical  line  routing  hole.  Refer  to  Electrical  and ? ...

  • Invacare 3800 - page 20

    SECTION 2—PARTS AND INSTALLATION Recessed Side Entry Bath Tubs 20 Part No 1150695 Plumbing Installation  DANGER Be certain all plumbing work is perfor med by a qualified plumber and is in compliance with local codes.  WARNING Some state and local pl umbing codes require the install ation of a “reduced pressure zone” (RPZ) assembly on bo ...

  • Invacare 3800 - page 21

    SECTION 2—PARTS AND INSTALLATION Part No 1150695 21 Recessed Side Entry Bath Tubs 10. Check  for  leaks  in  supply  or  drain  lines  and  check  operation  of  tub.  Refer  to  Operation  on  page 22. NOTE:  Check  local  codes  re g ar d i n g  maximum  water  temperature ...

  • Invacare 3800 - page 22

    SECTION 3—OPERATION Recessed Side Entry Bath Tubs 22 Part No 1150695 SECTION 3—OPERATION Overview The  tub  is  designed  to  improve  the  efficiency  and  environmental  safety  of  you r  facility ʹ s  operation.  Howev er ,  if  the  tub  is  not  operated  or  maintained ...

  • Invacare 3800 - page 23

    SECTION 3—OPERATION Part No 1150695 23 Recessed Side Entry Bath Tubs Disinfecting the Tub Using the Closed Loop System  WARNING Disinfect the tub after EACH us e to avoid resident infection and contamination of the tub. DO NOT disinfect the tub when it is occupied otherwise injury may occur. Read and understand all information on Invacare bran ...

  • Invacare 3800 - page 24

    SECTION 3—OPERATION Recessed Side Entry Bath Tubs 24 Part No 1150695 Opening/Closing the Tub Door  WARNING DO NOT open door when water is in th e tub, serious injury could result. NOTE:  For  this  proced ure,  ref er  to  FIGURE 3.1  on  page  24. Opening the Tub Door 1. Place  one  hand  on  top  of ...

  • Invacare 3800 - page 25

    SECTION 3—OPERATION Part No 1150695 25 Recessed Side Entry Bath Tubs Water Temperature Setting NOTE:  For  this  proced ure,  ref er  to  FIGURE 3.2.  DANGER ALWAYS hand test the inco ming water temper ature and the wate r temperature in the tub before immersing the re sident. Failure to do so may result in a scalding injury. ...

  • Invacare 3800 - page 26

    SECTION 3—OPERATION Recessed Side Entry Bath Tubs 26 Part No 1150695 Operating Shower/Massage Wand NOTE:  For  this  proced ure,  ref er  to  FIGURE 3.3. NOTE:  STEPS  1 ‐ 3  are  to  be  performed  while  holding  the  shower/massage  wand  over  the  tub. 1. T urn  shower/ma ...

  • Invacare 3800 - page 27

    SECTION 3—OPERATION Part No 1150695 27 Recessed Side Entry Bath Tubs FIGURE 3.4 Filling Tub Hydromassage CAUTION Before starting hy dromassage, water level MUST be completely above whirlpool jets otherwise damage to the motor/pump will result. NOTE:  For  this  proced ure,  ref er  to  FIGURE 3.5. 1. Close  the  aerator ? ...

  • Invacare 3800 - page 28

    SECTION 3—OPERATION Recessed Side Entry Bath Tubs 28 Part No 1150695 FIGURE 3.5 Hydromassage Whirlpool Aerator Whirlpool On/Off Button Drain Drain Plug DETAIL “A” DETAIL “C” DETAIL “B” Turn Counterclockwise to Open Whirlpool Jet Pull Out to Open Inlet Plug Whirlpool Inlet ...

  • Invacare 3800 - page 29

    SECTION 4—MAINTENANCE Part No 1150695 29 Recessed Side Entry Bath Tubs SECTION 4—MAINTENANCE NOTE:  Every  six  months  or  as  necessary  have  a  qualified  technician  perform  a  thorough  inspection  and  servicing.  Routine  maintenance  will  extend  the  life  and  ...

  • Invacare 3800 - page 30

    SECTION 4—MAINTENANCE Recessed Side Entry Bath Tubs 30 Part No 1150695 Maintenance Overview Cleaning the Door Seal Gasket The  rubber  door  seal  gasket  should  remain  clean  and  free  of  debri s.  Use  a  wor ki n g  solution  of  a  commercially  av ailable  heavy  duty  cle ...

  • Invacare 3800 - page 31

    SECTION 4—MAINTENANCE Part No 1150695 31 Recessed Side Entry Bath Tubs Heavy Duty Cleaning Procedure  WARNING The disinfectant dispensing system has been fact ory tested and calibrated for use with I nvacare disinfectant. The use of any disinfectant with a dilution ratio (½ oz. per gallon) or visco sity level different than that of Invacare d ...

  • Invacare 3800 - page 32

    SECTION 4—MAINTENANCE Recessed Side Entry Bath Tubs 32 Part No 1150695 Calibrating the Disinfectant Flow Meter  WARNING The disinfectant dispensing system has been factory te sted and calibrated for use with Invacare disinfectant. The use of any disinfectant wi th a dilution ratio (½ oz. per gallon) or viscosit y level different than that of ...

  • Invacare 3800 - page 33

    SECTION 4—MAINTENANCE Part No 1150695 33 Recessed Side Entry Bath Tubs 13. T urn  the  disinfectant  va l ve  to  the  on  position. NOTE:  Liquid  will  be  heard  filling  the  interior  plumbing  of  the  tub. 14. Note  the  position  of  the  floating  ball  in  the ...

  • Invacare 3800 - page 34

    SECTION 4—MAINTENANCE Recessed Side Entry Bath Tubs 34 Part No 1150695 Maintenance Record DATE MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED NOTES ...

  • Invacare 3800 - page 35

    SECTION 5—TROUBLESHOOTING Part No 1150695 35 Recessed Side Entry Bath Tubs SECTION 5—TROUBLESHOOTING NOTE:  If  pr oblems  are  not  rem ed i e d  by  the  suggested  means  above,  contact  an  ICCG  deal er  or  technical  support. SYSTEM/OPERATION SYMPTOMS FAULTS SOLUTION Hydromassage System ...

  • Invacare 3800 - page 36

    LIMITED WARRANTY PLEASE NOTE: THE WA RRANTY BELOW HAS BE EN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MA N UFACTURED AFTER JULY 4, 1975. This warranty is extended only to the o riginal purchaser/user of our pro ducts. This warranty gives you speci fic legal rights and you may also have other legal ri ghts which vary from state to st ...

メーカー Invacare カテゴリー Hot Tub

Invacare 3800のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 3800の取扱説明書
- Invacareの製品カード
- パンフレット
- またはInvacare 3800の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Invacare 3800の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Invacare 3800の取り付け説明書、サービスマニュアル、簡易説明書、またはInvacare 3800のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Invacare 3800の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Invacare 3800デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがInvacare 3800を使用するのを助ける技術的文書のことです。説明書は通常、全てのInvacare 3800ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Invacareの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Invacare 3800の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははInvacare 3800の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Invacare 3800に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Invacare 3800デバイスの基本機能を使うにあたってのヒント。 Invacare 3800のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Invacare 3800に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるInvacare 3800のメーカー/サービスへの連絡先に関する情報。

Invacare 3800についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもInvacare 3800の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがInvacare 3800で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)