Lincoln Electric LN-15 WIRE FEEDER IM910の取扱説明書

36ページ 2.42 mb
ダウンロード

ページに移動 of 36

Summary
  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 1

    OPERA TOR’S MANUAL • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • Copyright © Lincoln Global Inc. LN- 15 WIRE FEEDER IM910 February, 2009 For use with machi ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Us e suitable clothing made from durable flame-resistant material to protect your ski ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 4

    iii SAFETY iii FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. Nation ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 5

    iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits ? ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 6

    v SAFETY v 60974-10 ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 7

    vi SAFETY vi EN 60974-10: ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 8

    vii vii Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 9

    viii viii T ABLE OF CONTENTS Page Installation .......................................................................................................................Section A Technical Specifications .......................................................................................................A-1 Safety Precautions ....................... ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 10

    42 VAC/1/50/60 (5 Amps Maximum) CONTROL CABLE MODEL 500 Amps 60% Duty Cycle 350 Amps 100% Duty Cycle A-1 INST ALLA TION LN-15 CONTROL CABLE MODEL (CE) A-1 TEMPERA TURE RANGE OPERATION: - 20° C to +50° C (- 4° F to +122° F) STORAGE: - 40° C to +70° C (- 40° F to +158° F) RA TED CURRENT ELECTRODE DIAMETERS and SPEED RANGE PHYSICAL DIMENSIONS ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 11

    A-2 INST ALLA TION LN-15 CONTROL CABLE MODEL (CE) A-2 SAFETY PRECAUTIONS ELECTRIC SHOCK CAN KILL. • ONLY QUALIFIED PERSONNEL SHOULD PERFORM THIS INSTALLATION. • Turn off input power to the power source at the disconnect switch or fuse box before working on this equipment. Turn off the input power to any other equipment connected to the welding ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 12

    A-3 INST ALLA TION LN-15 CONTROL CABLE MODEL (CE) A-3 ELECTRODE CONNECTION Route the electrode cable through the strain relief in the rear of the case. Connect the electrode cable to the LN-15 connection block using the mounting hard- ware provided. Secure the cable by tightening the strain relief. All domestic models are supplied with an optional ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 13

    GUNS AND CABLES ASSEMBLIES A variety of Lincoln 10' (3.0m) or 15' (4.6m) gun and cable assemblies are available for use with the LN-15, including the Magnum™ models for GMAW, K126 or K115 models for Innershield®, and more. The LN-15 comes factory equipped with a K1500-2 gun connection kit, designed for guns having a Magnum Tweco™ com ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 14

    FEEDING WIRE ELECTRODE • ELECTRIC SHOCK CAN KILL. • When feeding electrode with the gun trigger, the electrode and wire drive mechanism are always "hot" to work and ground and could remain "hot" several seconds after the gun trigger is released . --------- -------------------------------------------------------------- 1. Tur ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 15

    B-1 OPERA TION LN-15 CONTROL CABLE MODEL (CE) B-1 • ELECTRIC SHOCK CAN KILL. Unless using COLD FEED fea- ture, when feeding with gun trig- ger, the electrode and drive mechanism are always electri- cally energized and could remain energized several sec- onds after the welding ceases.. • Do not attach the work clip to the roll cage or bottom ski ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 16

    B-2 OPERA TION B-2 GENERAL DESCRIPTION The LN-15 is a light weight, portable, durable semi- automatic wire feeder. The LN-15 accommodates spools 8" (200mm) diame- ter up to 4" (100mm) wide. The domestic feeders comes factory equipped with a K1500-2 Magnum Tweco-compatible style #2-#4 gun bushing. Other K1500 series gun bushings are avail- ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 17

    B-3 OPERA TION B-3 LN-15 CONTROL CABLE MODEL (CE) CASE FRONT CONTROLS (See Figure B.1) ACROSS THE ARC MODEL 1. WIRE FEED SPEED DISPLAY- The Wire Feed Speed display shows the rate the LN-15 will feed electrode dur- ing welding. The default WFS units for domestic models are inches/minute and can be changed to meters/minute through the configuration m ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 18

    B-4 OPERA TION LN-15 CONTROL CABLE MODEL (CE) B-4 LN-15 POWER-UP SEQUENCE Normal Power-Up Display When power is first applied to the LN-15, the display will momentarily show set-up information. For exam- ple, it may show "CV" and "HI" , indicating operation from a CV power source and the wire drive is config- ured for the high s ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 19

    B-5 OPERA TION LN-15 CONTROL CABLE MODEL (CE) B-5 Rotate the WFS knob until the desired parameter is displayed. CV/CC Mode: WFS Units: 2. Activate and release the GAS PURGE switch to select the parameter. The present value will then display in the right hand side of the display. Example: 3. Rotate the WFS knob to change the parameter set- ting. CV/ ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 20

    B-6 OPERA TION B-6 LN-15 CONTROL CABLE MODEL (CE) 6. Remove the outer wire guide, and push the gun bushing out of the wire drive. Because of the pre- cision fit, light tapping may be required to remove the gun bushing. 7. Disconnect the shielding gas hose from the gun bushing, if required. 8. Connect the shielding gas hose to the new gun bushing, i ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 21

    B-7 OPERA TION B-7 LN-15 CONTROL CABLE MODEL (CE) SCFH Liter/Min. 10 4.7 20 9.4 30 14.2 40 18.9 50 23.6 60 28.3 70 33.1 80 37.8 SPINDLE BRAKE Adjust the spindle brake tension to allow the spool to spin freely, yet have enough resistance for little or no overrun when wire feeding is stopped. SHIELDING GAS CONNECTION CYLINDER may explode if damaged. ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 22

    B-8 OPERA TION B-8 LN-15 CONTROL CABLE MODEL (CE) CONST ANT CURRENT OPERA TION ( See Figure B.3) Lincoln Electric does NOT recommend constant current semiautomatic welding for applications which need to meet specified weld metal chemical or mechanical property requirements or weld quality requirements. ---------------------------------------------- ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 23

    B-9 OPERA TION B-9 SETTING ARC SENSING WIRE FEED SPEED FOR CONSTANT CURRENT OPERATION When using a constant current (formerly variable voltage) power source, welding performance is im proved using arc sensing wire feed speed (CC operation). In this wire feed mode the wire speed increases if arc voltage increases, and decreases if arc voltage de cre ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 24

    B-10 OPERA TION B-10 MAKING A WELD The serviceability of a product or structure utilizing the LN-15 wire feeder is and must be the sole responsibil- ity of the builder/user. Many variables beyond the con- trol of The Lincoln Electric Company affect the results obtained in using the LN-15 wire feeder. These vari- ables include, but are not limited t ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 25

    C-1 ACCESSORIES C-1 LN-15 CONTROL CABLE MODEL (CE) WIRE TYPE ELECTRODE SIZE KP KIT Steel Wires: .023-.030" (0.6-0.8mm) KP1696-030S (Including stainless steel) .035" (0.9mm) KP1696-035S .040-.045" (1.0-1.2mm) KP1696-045S .052" (1.4mm) KP1696-052S .035-.045" (0.9-1.2mm) KP1696-1 .040" (1.0mm) KP1696-2 Cored Wires: .030-. ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 26

    D-1 MAINTENANCE D-1 LN-15 CONTROL CABLE MODEL (CE) ELECTRIC SHOCK can kill. • Do not operate with covers removed. • Turn off power source before installing or servicing. • Do not touch electrically hot parts. • Turn the input power to the welding power source off at the fuse box before working in the terminal strip. • Only qualified perso ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 27

    E-1 TROUBLESHOOTING E-1 LN-15 CONTROL CABLE MODEL (CE) If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you loc ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 28

    E-2 TROUBLESHOOTING E-2 LN-15 CONTROL CABLE MODEL (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 29

    E-3 TROUBLESHOOTING E-3 LN-15 CONTROL CABLE MODEL (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 30

    E-4 TROUBLESHOOTING E-4 LN-15 CONTROL CABLE MODEL (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 31

    F-1 DIAGRAMS F-1 LN-15 CONTROL CABLE MODEL (CE) NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equ ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 32

    F-2 DIMENSION PRINT F-2 LN-15 CONTROL CABLE MODEL (CE) ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 33

    NOTES LN-15 CONTROL CABLE MODEL (CE) ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 34

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA EL ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 35

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes fr ...

  • Lincoln Electric LN-15 WIRE FEEDER IM910 - page 36

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

メーカー Lincoln Electric カテゴリー Welder

Lincoln Electric LN-15 WIRE FEEDER IM910のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LN-15 WIRE FEEDER IM910の取扱説明書
- Lincoln Electricの製品カード
- パンフレット
- またはLincoln Electric LN-15 WIRE FEEDER IM910の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lincoln Electric LN-15 WIRE FEEDER IM910の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lincoln Electric LN-15 WIRE FEEDER IM910の取り付け説明書、サービスマニュアル、簡易説明書、またはLincoln Electric LN-15 WIRE FEEDER IM910のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lincoln Electric LN-15 WIRE FEEDER IM910の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lincoln Electric LN-15 WIRE FEEDER IM910デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLincoln Electric LN-15 WIRE FEEDER IM910を使用するのを助ける技術的文書のことです。説明書は通常、全てのLincoln Electric LN-15 WIRE FEEDER IM910ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lincoln Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lincoln Electric LN-15 WIRE FEEDER IM910の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLincoln Electric LN-15 WIRE FEEDER IM910の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lincoln Electric LN-15 WIRE FEEDER IM910に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lincoln Electric LN-15 WIRE FEEDER IM910デバイスの基本機能を使うにあたってのヒント。 Lincoln Electric LN-15 WIRE FEEDER IM910のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lincoln Electric LN-15 WIRE FEEDER IM910に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLincoln Electric LN-15 WIRE FEEDER IM910のメーカー/サービスへの連絡先に関する情報。

Lincoln Electric LN-15 WIRE FEEDER IM910についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLincoln Electric LN-15 WIRE FEEDER IM910の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLincoln Electric LN-15 WIRE FEEDER IM910で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)