    SE95008 Rev . 3 Operators Manual Installation, Operation & Service Direct Steam T able T op Kettles T able-T op Direct Steam Kettles MODELS: KDT- 1 - T KDT- 3 - T KDT- 6 - T KDT-12 - T KDT-20 - T SD Stands MODELS: SD - 450 SD - 650 SD - 760 SD -1050 SD -1200 SD -1600 SD -1800 Kettles on SD Stands MODELS: SD - 450 - K 6 SD - 650 - K 12 SD - 760 ...

  • Cleveland Range KDT-20-T - page 2

    T ABLE OF CONTENTS Installation General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Clearance Requir ements . . . . . . ...

  • Cleveland Range KDT-20-T - page 3

    1 GENERAL Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of product could cause injury or damage. This unit is built to comply with applicable standards for manufactur ers. Included among those approval agencies ar e: UL, NSF , ASME/Ntl.Bd., ...

  • Cleveland Range KDT-20-T - page 4

    2 STEAM All steam plumbing to and from the kettle and steam boiler should be thoroughly cleaned and inspected for dirt and debris before final connection to the kettle are made. Generally , kettles r equire 1/2" i.p.s. pipe, 10-45 psi steam pressur e. If the steam supply pressur e exceeds 45 psi, a pressur e reducing valve is requir ed. The st ...

  • Cleveland Range KDT-20-T - page 5

    OPERA TION 1. Ensur e that ther e is an adequate steam supply to the kettle. 2. T urn the steam control valve to the open position by turning the knob counter -clockwise, then allow the kettle to preheat. NOTE: When cooking egg and milk products, the kettle should NOT be preheated, as pr oducts of this nature adher e to hot cooking sur faces. These ...

  • Cleveland Range KDT-20-T - page 6

    4 CARE AND CLEANING Y our kettle must be cleaned r egularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, r eliable operation. W ARNING: Do not use chloride base detergents. 1. Prepar e a war m water and mild detergent solution in the kettle. 2. Remove food soil inside the kettle using a nylon brush. Do not ...

  • Cleveland Range KDT-20-T - page 7

    5 STEAM CONTROL ASSEMBL Y SER VICE P AR TS 1 15 16 2 3 4 5 5 22 6 7 8 9 10 1 13 14 21 20 19 18 17 25 4 23 24 12 4 5 3 21 20 19 18 17 5 6 7 8 9 4 23 7 8 9 23 6 7 8 9 4 23 13 12 5 26 28 7 8 23 30 27 29 11 1 5 4 ...

  • Cleveland Range KDT-20-T - page 8

    6 STEAM CONTROL ASSEMBL Y ITEM NO . P ART NO . DESCRIPTION QTY . 1. F A11056 Binding Head Screw , 6-32 x 1/2" lg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2. KE50458 End Cap, condensate return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE50455-1 T runnion, condensate return . . . . . ...

  • Cleveland Range KDT-20-T - page 9

    7 3 4 7 6 5 11 1 0 9 8 16 12 13 15 14 22 21 19 18 20 Se e S tea m Co ntr ol Dra wing 2 1 1 1 24 28 1 25 2 6 27 30 Se e S tea m Co ntr ol Dra wing 2 3 17 Steam In Configuration for SD Stand with Two Kettles 2 2 CONDENSATE CONDENSATE RETURN RETURN STEAM STEAM IN IN STEAM IN CONDENSATE RETURN Se e S tea m Co ntr ol Dra wing STEAM STEAM IN IN STEAM IN ...

  • Cleveland Range KDT-20-T - page 10

    8 PLUMBING ASSEMBL Y (for SD Stands) ITEM NO . P ART NO . DESCRIPTION QTY . 1. FI00169 T ee, 1/2" NPT . (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . . . . . . . .3 2. KE51723 Pressur e Relief V alve, 1/2" NPT (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . . . . . . ...

  • Cleveland Range KDT-20-T - page 11

    9 6 7 8 4 5 1 4 2 3 1 2 3 1 1 1 2 9 1 1 1 2 1 0 F AUCET ASSEMBLIES ...

  • Cleveland Range KDT-20-T - page 12

    10 F AUCET ASSEMBLIES ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE50825-8 6 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 12 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 20 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range KDT-20-T - page 13

    PRESSURE RELIEF V AL VE TESTING PROCEDURE The pressur e relief valve (optional on kettles) must be checked at least twice a year as part of the normal maintenance per formed. 1. Open steam valve and preheat kettle. 2. Stand to the side of the pressur e relief valve discharge tube and pull ring three or four times to insure fr ee movement. Hold valv ...

  • Cleveland Range KDT-20-T - page 14

    TROUBLESHOOTING GUIDE This section contains information intended for use by Authorized Service Personnel only . PROBLEM A / Kettle heats too slowly or does not come to a boil. Pr obable Cause Remedy 1. Inadequate steam flow . Check for correct steam using chart below . If kettle is connected to a steamer and power ed by a generator the units should ...

  • Cleveland Range KDT-20-T - page 15

    9.88" 251mm 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN 8.00" 203mm 9.38" 238mm 12.25" 311mm 12.50" 318mm 8.13" 207mm 9.31" 236mm 1.56" 40mm 3.50" 89mm 13 SPECIFICA TION DRA WINGS KDT -1-T CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURF A CES: Right - 4" Left - 0 Back - 0 ...

  • Cleveland Range KDT-20-T - page 16

    14 F G NOTE: INLET AND RETURN NOT INTERCHANGABLE C A B WALL E D H 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN STEAM CONTROL VALVE K M L N J 1.00" 25mm 1.25"/32mm WALL 2.25" 57mm GAL. LITRE A B C D E F G H J K L M N 3 11 IN 14.00 10.00 15.13 12.50 8.25 10.00 12.50 23.00 7.00 4.00 11.00 15.00 21.00 mm 356 254 384 317 210 ...

  • Cleveland Range KDT-20-T - page 17

    15 F G NOTE: INLET AND RETURN NOT INTERCHANGABLE C A B WALL E D 1/2" NPT STEAM INLET 1/2" NPT CONDENSATE RETURN K M J 1.75" 45mm WALL H STEAM CONTROL VALVE 1.25" 32mm 2.25" 57mm L MARINE LOCK GAL. LITRE A B C D E F G H J K L M 3 11 IN 20.50 16.75 23.00 22.25 13.50 19.50 22.00 29.00 6.00 8.75 11.50 29.50 mm 521 425 584 565 3 ...

  • Cleveland Range KDT-20-T - page 18

    SD ST ANDS WITH KETTLES CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURF A CES: Right - 0 Left - 0 Back - 0 MARINE LOCK SLIDING DRAIN PAN 18.00" 457mm 6.00" 152mm A 27.75" 706mm 22.00" 610mm 1.47" 37mm 1.47" 37mm H C 16.88" 429mm 13.75" 349mm 33.50" 851mm D 5.00" 127mm 3.25" 83mm B ...

メーカー Cleveland Range カテゴリー Hot Beverage Maker

Cleveland Range KDT-20-Tのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- KDT-20-Tの取扱説明書
- Cleveland Rangeの製品カード
- パンフレット
- またはCleveland Range KDT-20-Tの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Cleveland Range KDT-20-Tの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Cleveland Range KDT-20-Tの取り付け説明書、サービスマニュアル、簡易説明書、またはCleveland Range KDT-20-Tのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Cleveland Range KDT-20-Tの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Cleveland Range KDT-20-Tデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCleveland Range KDT-20-Tを使用するのを助ける技術的文書のことです。説明書は通常、全てのCleveland Range KDT-20-Tユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Cleveland Rangeの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Cleveland Range KDT-20-Tの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCleveland Range KDT-20-Tの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Cleveland Range KDT-20-Tに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Cleveland Range KDT-20-Tデバイスの基本機能を使うにあたってのヒント。 Cleveland Range KDT-20-Tのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Cleveland Range KDT-20-Tに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCleveland Range KDT-20-Tのメーカー/サービスへの連絡先に関する情報。

Cleveland Range KDT-20-Tについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCleveland Range KDT-20-Tの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCleveland Range KDT-20-Tで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)