Asante Technologies 3500の取扱説明書

36ページ 0.61 mb
ダウンロード

ページに移動 of 36

Summary
  • Asante Technologies 3500 - page 1

    IntraCore ™ 3500 Series Gigabit E therne t Sw itches Getting Started Gui de ...

  • Asante Technologies 3500 - page 2

    2 Gettin g Start ed Guid e Quick Start Guide Follow the se steps t o install y our IntraCore switch: 1 . Open the box and check the cont ents. See Chapter 1.1 Package Contents for a complete lis t of the items included with your IntraCore switch. 2. Install the switch i n an equip ment or wall r ack, or prep are it for desktop pla cement. 3. Connec ...

  • Asante Technologies 3500 - page 3

    3 Asant é Intra Core 3 500 Ser ies T able of Contents Quick Start G uide 2 1. Introducti on 5 1.1 Packa ge Contents 6 1.2 LED s 6 1.3 Front Pa nel Descript ion 10 1.4 M anagement and C onfigur ation 11 2. Installat ion and S etup 13 2.1 Saf ety Overview 13 2.2 Re commended Ins tallation T ools 14 2.3 Pow er Requirements 14 2.4 Enviro nmental Requ ...

  • Asante Technologies 3500 - page 4

    4 Gettin g Start ed Guid e ...

  • Asante Technologies 3500 - page 5

    5 Asant é Intra Core 3 500 Ser ies 1 Introducti on Thank you for purcha sing the Asanté IntraCore 3500 Series Gigabit switch. T he IntraCore 3500 se ries include 24- and 48- port 10/100 managed sw itches w ith a varie ty of hardware a nd software o ptions. The IntraCore 3524 is a 24-port 10/100 managed sw itch with sev- eral optional hardw are mo ...

  • Asante Technologies 3500 - page 6

    6 Gettin g Start ed Guid e The system can operate as a stan d-alone netw ork or be use d in combinatio n with oth er IntraCo re series sw itches in th e backb one. 1.1 Package Contents The follow ing items are includ ed in your pack age: • Switch • AC power cord • Rack mount br acket s with screw s • Rubber feet • Ref erenc e Guid e • U ...

  • Asante Technologies 3500 - page 7

    7 Asant é Intra Core 3 500 Ser ies Port # LED Color Description 25,26 Gigabi t (speed) Solid Green Off A valid 1000Mbps link has been established No link has been estab- lished, or link is at 10/100Mbps rate 25,26 10/ 100 Link Solid Green Solid Amber Off A valid 100Mbps link has been established A valid 10Mbps li nk has been established No 10/100 ...

  • Asante Technologies 3500 - page 8

    8 Gettin g Start ed Guid e 1.2.2 IC3548-2GT The IntraCore 3548-2GT switch has tw o LED status indicator s for each of the 4 8 10/100 port s and the 2 Gigabit ports. Using the M ode button on the lower left of the front p anel allow s the user to convert between Li nk/Activity status and D uplex status display s. See the tables below for more infor ...

  • Asante Technologies 3500 - page 9

    9 Asant é Intra Core 3 500 Ser ies Port # LED Color Description N/A Pow er/Syste m Green Off Pow er is on Power is o ff 1-48 (10/100) Link/Act ivity Solid Gre en Blinking Green Solid Amber Blinking Am ber Off A valid 100Mbps link has been established Data transf er at 100Mbps A valid 10Mbps li nk has been established Data transf er at 10Mbps No li ...

  • Asante Technologies 3500 - page 10

    10 Gettin g Start ed Guid e 1.3 Front and Back Panel Descriptions Refer to the f ollowing se ctions for detailed d escriptions o f the front and back pa nels of the IntraCo re 3500 serie s switches . 1.3.1 IC3524 Mo dels From left to ri ght, the fr ont panel conta ins the fol lowing: Pow er and port LEDs; 24 10/100 port s; 2 optional module slot s; ...

  • Asante Technologies 3500 - page 11

    11 Asant é Intra Core 3 500 Ser ies From left t o right, the b ack panel, s hown below , contains: a console port; a 12V DC j ack for an external pow er supply (IC35-RP S12, US part number 99- 00777-01, s old separat ely); an AC socket (for pri- mary pow er) and a pow er switch. 1.4 Management and C onfiguration There are thr ee different methods ...

  • Asante Technologies 3500 - page 12

    12 Gettin g Start ed Guid e nection to for m a stack (multipl e units shar ing one IP ad dress). T he stacking fe ature is av ailable o n the IC3524 m odels, ver sions 1.1 or higher. See C hapter 2.11 U sing the Stac king Feature for more de- tails. 1.4.2 Web -Based Int erface With Intern et access, u sers can link d irectly to t he local switch’ ...

  • Asante Technologies 3500 - page 13

    13 Asant é Intra Core 3 500 Ser ies 2 Installation and Setup This chapte r ex plains how to install an d connect the switc h to your netw ork. To conf igure the sw itch for ma nagement, r efer to the User’s M anual on th e CD-ROM . The follow ing guidel ines will help you pre pare to ins tall the switch i n such a w ay that it h as the proper po ...

  • Asante Technologies 3500 - page 14

    14 Gettin g Start ed Guid e • Do not tamp er with the int ernal component s of your sw itch. This could v oid your w arranty • Examine you r work area for potenti al hazards (I.e. w et floors, ungrounded c ables, etc .) and eli minate them before inst alling your sw itch For more safety informati on, please refer to the Us er’s Manual. 2.2 Re ...

  • Asante Technologies 3500 - page 15

    15 Asant é Intra Core 3 500 Ser ies Failure to observe th ese limit s may ca use damag e to the sw itch and void the war rant y. Avoid direct sunlig ht, heat sou rces, or area s with hig h levels of electromagn etic interfer ence. 2.5 Cooling and Airflow The sw itch uses intern al fans for air coolin g. Do not restrict air flow by covering or obst ...

  • Asante Technologies 3500 - page 16

    16 Gettin g Start ed Guid e To mount t he switch o nto an equip ment rack: 1. Place the sw itch on a flat, stab le surface. 2. Locate a r ack-mounting bracket (su pplied) and place it over the mounting ho les on one side of the unit. 3. Use the screw s (supplied) to se- cure the br acket (with a Phillip s screwdriv er). 4. Repeat the tw o previous ...

  • Asante Technologies 3500 - page 17

    17 Asant é Intra Core 3 500 Ser ies 2. Place the uni t on a flat surface w ith a minimum area of 434.3 mm x 342.9 mm (17.1” x 13.5”) and sup port capaci ty of 10 kg (22 lbs ). 3. Make sure th ere is enou gh ventila tion spac e between the switch an d surroundi ng walls o r object s. 2.8 Installing G BIC Interfaces Instruction s for instal ling ...

  • Asante Technologies 3500 - page 18

    18 Gettin g Start ed Guid e 2.8.3 GBIC C are and Han dling Follow the se GBIC main tenance g uidelines: • Unnecessary removal a nd insertion of a GBIC can le ad to its premature failure. A G BIC connector has a lifet ime of 100 to 500 re movals/in sertions • GBICs are static-sensitive. To pr event ESD damage, follo w your normal board and compo ...

  • Asante Technologies 3500 - page 19

    19 Asant é Intra Core 3 500 Ser ies 2.10 Connecting Power Use the fol lowing proc edure to con nect power to t he sw itch: Important! Carefu lly review the power requirem ents (Chapte r 2.3) before conne cting pow er to the uni t. 1. Plug one end o f the suppl ied pow er cord into t he power con- nector on the back of the unit. 2. Plug the ot her ...

  • Asante Technologies 3500 - page 20

    20 Gettin g Start ed Guid e Note : There is no uplink po rt on this sw itch. All 10/ 100 ports on this switch are auto-sens ing MDI/M DI-X. This adv anced featur e means that the 1 0/100 ports w ill automati cally det ermine whether the de- vice at the other end of t he lin k is a hub, sw itch or w orkstatio n, and adjust its signal s accordingly . ...

  • Asante Technologies 3500 - page 21

    21 Asant é Intra Core 3 500 Ser ies 2.11.2 Gigabit Ethernet P orts Cabling Pro cedur es Cabling re quirements for the G igabit Ethernet modules d epend on the type of G BIC interfa ce that has been insta lled. Use th e following guidelines to deter mine the cablin g requiremen ts for your GB IC: • 1000BaseSX GBIC: Cables with SC -type fiber conn ...

  • Asante Technologies 3500 - page 22

    22 Gettin g Start ed Guid e • All stacked uni ts are mana ged through c onnection to the master sw itch, via con sole, tel net or web i nterfaces Note : While the u ser may m anage the s tack via console, telnet or w eb interface, the initi al formation of the stac k may only b e done by connecti on to a cons ole. • The switches nee d no ex tra ...

  • Asante Technologies 3500 - page 23

    23 Asant é Intra Core 3 500 Ser ies console co nnection t o the fir st unit. Type k in the Con figuratio n Menu to acc ess the Sta cking M anagement menu, shown be - low. Ty pe t to toggle the sw itch from “di sabled” to “e nabled”. Repeat for a ll remaini ng units. IntraCore 3524 Configuration Menu <Cmd> <Description> a System ...

  • Asante Technologies 3500 - page 24

    24 Gettin g Start ed Guid e 4. After all units have had stacking ena bled, conn ect the con sole to the fir st unit (the M aster unit). 5. Power cy cle the whole stack, or, if t he units ar e to be p owered up separately , power the M aster last. 6. Go to the M aster’s Stac k Managem ent menu a nd type s to b e- gin the a utomatic for mation of t ...

  • Asante Technologies 3500 - page 25

    25 Asant é Intra Core 3 500 Ser ies Appendix A T roubl eshooting In the unlik ely event your network d oes not oper ate properly , follow the troublesh ooting t ips below : 1. CHECK YOUR POW ER CONNECTION. Is the Power LED on? If not, plug th e power cord i nto another k nown w orking AC out- let. 2. CHECK YOUR NETW ORK CABLES. Are the LINK LEDs o ...

  • Asante Technologies 3500 - page 26

    26 Gettin g Start ed Guid e ...

  • Asante Technologies 3500 - page 27

    27 Asant é Intra Core 3 500 Ser ies Appendix B Safety an d Regulator y Com- pliance FCC Complianc e Stateme nt This equ ipment ha s been test ed and found t o comply with the li mits for a Class A di gital dev ice, pursuan t to part 15 of the FCC R ules. These limit s are de signed to provide re asonable pr otection a gainst harmful interf erence ...

  • Asante Technologies 3500 - page 28

    28 Gettin g Start ed Guid e ...

  • Asante Technologies 3500 - page 29

    29 Asant é Intra Core 3 500 Ser ies Appendix C Features and Specif ications The IntraCore 3500 Series are Asanté’ s most pow erful, flex ible workgroup switches. See the User’s M anual for det ailed feat ures and specificat ions. Features • Asanté Auto-U plink ™ on all 10/100 and 10/100/1 000BaseT ports (auto MDI/MD I-X) • 6.4 Gbps no- ...

  • Asante Technologies 3500 - page 30

    30 Gettin g Start ed Guid e ...

  • Asante Technologies 3500 - page 31

    31 Asant é Intra Core 3 500 Ser ies Appendix D Serial Port Pin Outs The console port is us ed to connec t with a ter minal using a DB-9 female conn ector. T he setting is 9 600-N81. Se e the table bel ow for a list of pin outs. Pin Number Signal Name 1 CD Carrier Detect 2 RD Receive Data 3 TD Transmit D ata 4 DTR Data Termin al Ready 5 SG Signal G ...

  • Asante Technologies 3500 - page 32

    32 Gettin g Start ed Guid e ...

  • Asante Technologies 3500 - page 33

    33 Asant é Intra Core 3 500 Ser ies Appendix E W arranty and Support The IntraCore switch is covered by Asanté’s 3-year IntraCare ™ product w arranty and advan ced techni cal suppor t. An additio nal 2 year w arranty is availab le through A santéCare ™ . See t he User’s Manual for m ore detailed informati on. If, after att empting the tr ...

  • Asante Technologies 3500 - page 34

    34 Gettin g Start ed Guid e ...

  • Asante Technologies 3500 - page 35

    35 Asant é Intra Core 3 500 Ser ies ...

  • Asante Technologies 3500 - page 36

    IntraCore 3500 Ser ies Gigabi t Ethernet Switch es Getting Starte d Guide Asanté T echnologie s, Inc. 821 Fox Lane San Jose, C A 95131 USA S ALES 800-662-9686 H ome/Of fice Solutio ns 800-303-9121 En terprise Solu tions 408-435-8388 T EC HNICA L S UPPOR T 801-566-8991 Worldw ide 801-566-3787 F AX www .asante.com support@a sante.com Copyright © 20 ...

メーカー Asante Technologies カテゴリー Switch

Asante Technologies 3500のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 3500の取扱説明書
- Asante Technologiesの製品カード
- パンフレット
- またはAsante Technologies 3500の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Asante Technologies 3500の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Asante Technologies 3500の取り付け説明書、サービスマニュアル、簡易説明書、またはAsante Technologies 3500のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Asante Technologies 3500の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Asante Technologies 3500デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAsante Technologies 3500を使用するのを助ける技術的文書のことです。説明書は通常、全てのAsante Technologies 3500ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Asante Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Asante Technologies 3500の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAsante Technologies 3500の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Asante Technologies 3500に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Asante Technologies 3500デバイスの基本機能を使うにあたってのヒント。 Asante Technologies 3500のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Asante Technologies 3500に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAsante Technologies 3500のメーカー/サービスへの連絡先に関する情報。

Asante Technologies 3500についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAsante Technologies 3500の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAsante Technologies 3500で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)