Eminent EM8622の取扱説明書

23ページ 関係なし
ダウンロード

ページに移動 of 23

Summary
  • Eminent EM8622 - page 1

    EM8622 Wireless Control Panel ...

  • Eminent EM8622 - page 2

    2 | ENGLISH EM8622 - Wireless Control Panel Table of contents 1.0 Introduction ...... ...... ......... ...... ..... ...... ......... ...... ...... ..... ......... ...... ...... ...... ........ ...... .. 3 1.1 Packing content s ...... ......... ...... ...... ..... ......... ...... ...... ...... ........ ...... ...... ...... ...... .... 3 1.2 Control ...

  • Eminent EM8622 - page 3

    3 | ENGLISH 1.0 Introduction Congratulations w ith the purchase of thi s high-quality Eminent product ! This prod uct has undergone ex tensive testing by Eminen t’s technical ex perts. Should you experience any pro blems with this pro duct, you are covered by a five- year Eminent warranty. Please keep this manual and the receipt in a safe place. ...

  • Eminent EM8622 - page 4

    4 | ENGLISH 1.3 Control panel ins ide 2.0 Installation Install the batteries and mount the control panel on the door fra me or the w all before use. Battery contact, plea se check positive and negative terminals Battery compartment Tamper switch Wired cable connection Red wire = + 12V Black wire = - GND ...

  • Eminent EM8622 - page 5

    5 | ENGLISH 1) Remove the screw and open the ca se 2) Install the batteries ac cording to th e positive and negative sign s (Re move the insulating strip be fore the first use) 3) Mount the backcover on the door fr ame or wall 4) Close the case and replace the sc rew Note : Opening the cover will trigger the tamp er switch ! You can disar m it by e ...

  • Eminent EM8622 - page 6

    6 | ENGLISH If there is an intru sion the alarm sy stem will be trigger ed, the siren w ill hoot and the alarm sy stem will send an SMS and au to dial to pre-stored phone numbers to notify u sers. Note : When an en try delay is set, the external control pane l will NOT warn you with an audio signal when a sensor is t riggered. Only the alarm system ...

  • Eminent EM8622 - page 7

    7 | ENGLISH 3.2.2 Using RFID Tag to disarm If direct disar m by RFID tag is disa bled (this is the defaul t power saving mode when using batteries), u ser needs to press [* ] to wake up the control panel and then put RFID tag close to the reade r to di sarm the alar m system.. When the pow er saving function is disabled, user can put the RFID t ag ...

  • Eminent EM8622 - page 8

    8 | ENGLISH 3.2.4 Emergency Call When the control panel is in SOS Speed Dial mode, u ser just holds the [SOS] key for 3 seconds, the LED indicator flashes once, the con trol panel beeps once, and the alarm system alar ms immediately. When the control panel is not in SOS Speed Dial mode , user needs to inpu t user code or admin code befor e holding ...

  • Eminent EM8622 - page 9

    9 | ENGLISH 4.0 Connect to the alarm sy stem Note : The default admin code is : 1 23456. See chapter “Ch ange Ad min Code” to change it. Note : The default user code is : 12 34. See chapter “Change User Code” to change it. Make sure the alar m system is in connection state (pres s code on alarm syste m and press the me mo button). Input the ...

  • Eminent EM8622 - page 10

    10 | ENGLISH 3. Put the RFID tag close to the RFID re ader. If one beep is heard the connecting is successful. When 2 beeps are hea rd, the RFID tag w as already connected to the control panel. To remove all conne cted RFID tag s, input the admin code followed by the # button. Press and hold down the 9 button for six seconds. All RFID tags are clea ...

  • Eminent EM8622 - page 11

    11 | ENGLISH 6.0 Settings Before changing the settings of th e control panel, the control panel sho uld be in “setup-state”. 6.1 Enter Setup-s tate Note : The default adm in code is : 123456 Input the admin code fol lowed by the [#] button to w ake up the control panel. Press [3] to enter the se tup-state. The LED indicator w ill be on. Note : ...

  • Eminent EM8622 - page 12

    12 | ENGLISH After setting a delay time, press the [Arm] button on the con trol pan el. The control panel will send the Arm command to the alarm system afte r the delay time you set in the control panel . Note : This setting will not apply to the Hom e mode. If both the control panel and the alarm system ha ve a delay time set, the a ctual delay ti ...

  • Eminent EM8622 - page 13

    13 | ENGLISH 6.3.1 Disable SO S code Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the setup is successful. 6.3.2 Enable SOS code Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the setup is successful. Note : Default setting i s 0, SOS cod ...

  • Eminent EM8622 - page 14

    14 | ENGLISH 6.4 Keyboard tone Keyboard tones can be switched o n or off. If they are switched of f, the beep when a setup is successful w ill also be swit ched off ! 6.4.1 Disable key board tone Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the setup is successful. 6.4.2 Enable key board tone ...

  • Eminent EM8622 - page 15

    15 | ENGLISH 6.5 Disarm system by RFID tag Users can enable or disable the function of d isarming the alar m system by RFID tag , or disarming silent by RFID tag. 6.5.1 Disable disar ming by RFID tag Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the setup is successful. 6.5.2 Enable disarming ...

  • Eminent EM8622 - page 16

    16 | ENGLISH 6.5.3 Disarming silently by RFID tag The alarm panel an d siren will hoo t twice when disar ming the alarm system by RFID tag. If set disar ming silently by RFID tag, the alarm syste m and siren will keep silent when disarming. Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the set ...

  • Eminent EM8622 - page 17

    17 | ENGLISH 6.6.1 Enable power savi g mode Enter Setup-state and input : When one beep i s heard and the L ED indicator keeps on for 10 seconds, the setup is successful. 6.6.2 Disable po wer saving mod e If the control panel is powered by an external 12V pow er supply (not included), i t is recommended to switch of the po wer saving mode. User s c ...

  • Eminent EM8622 - page 18

    18 | ENGLISH 6.7 Change user code A user can use its own code to wake up the control panel and send Ar m, Disarm or Home mode command s to the alarm syste m. The control panel can only hav e one user code. Note : The default user code is 1234. Please change this code at first use ! Enter Setup-state and input : When one beep i s heard and the L ED ...

  • Eminent EM8622 - page 19

    19 | ENGLISH 6.9 Reset the control panel After a reset the u ser code, admin code and all other setting s will be restored to default. Only the connected RFID t ags will remain wo rking. To remove the conne cted RFID tags, please refer to chapter “Connect RFID Tag to control panel”. Enter Setup-state and input : When one beep i s heard and the ...

  • Eminent EM8622 - page 20

    20 | ENGLISH 8.0 Service and su pport This user’s manual has been carefu lly written by Eminen t’s technical experts. If you have problems in stalling or using t he product, please fill out the support for m at the website www .eminent-online.com/supp ort . You can also conta ct us by phone. Below you w ill find a list with phone nu mbers for e ...

  • Eminent EM8622 - page 21

    21 | ENGLISH 9.0 Warning and p oints of attention Due to laws, directive s and regulat ions set out by the Europ ean parlia ment, some (wireless) devices could be subject to limitations concerning i ts use in certain European member states. In certai n European member states the use of su ch devices could be prohibited. Con tact your ( local) gover ...

  • Eminent EM8622 - page 22

    22 | ENGLISH 10.0 Warranty conditions The five-year Eminen t warranty ap plies to all Eminent produc ts, unless mentione d otherwise before or during the momen t of purchase. After buy ing a second -hand Eminent produc t the remaining per iod of warranty is measured from the moment of purchase by the produ ct’s initial ow ner. Eminent warran ty a ...

  • Eminent EM8622 - page 23

    23 | ENGLISH 11.0 Declaration of Conformity Application of Council Dire ctives: Manufacturer’s Na me: Eminent Type of Equip ment: Control panel Equipment Class: Commercial, Light Industrial, Cons umer PRODUCTNUM BER: EM8622 Conforms to the following standar ds: EN 301 489-1 V1.9.2 :2011 EN 301 489-3 V1.4.1 :2002 EN 300 220-1 V2.3.1 :2010 EN 300 2 ...

メーカー Eminent カテゴリー Security access control system

Eminent EM8622のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EM8622の取扱説明書
- Eminentの製品カード
- パンフレット
- またはEminent EM8622の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Eminent EM8622の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Eminent EM8622の取り付け説明書、サービスマニュアル、簡易説明書、またはEminent EM8622のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Eminent EM8622の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Eminent EM8622デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEminent EM8622を使用するのを助ける技術的文書のことです。説明書は通常、全てのEminent EM8622ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Eminentの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Eminent EM8622の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEminent EM8622の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Eminent EM8622に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Eminent EM8622デバイスの基本機能を使うにあたってのヒント。 Eminent EM8622のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Eminent EM8622に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEminent EM8622のメーカー/サービスへの連絡先に関する情報。

Eminent EM8622についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEminent EM8622の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEminent EM8622で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください