Haier AB212XCEAAの取扱説明書

28ページ 0.6 mb
ダウンロード

ページに移動 of 28

Summary
  • Haier AB212XCEAA - page 1

    Please read this operation manual before using the air conditioner . No.0010577706 Operation & Installation Manual CASSETTE TYPE AIR CONDITIONER Please keep this manual carefully and safely . AB212XCEAA ...

  • Haier AB212XCEAA - page 2

    Contents Cautions ............................................................................................. Introduction to Spare Parts ................................................................... Maintenance ....................................................................................... T rouble Shooting ........................ ...

  • Haier AB212XCEAA - page 3

    Cautions 1 Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The v ...

  • Haier AB212XCEAA - page 4

    2 All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner . Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting an ...

  • Haier AB212XCEAA - page 5

    3 W ARNING! Carefully r ead the following information in order to operate the airconditioner correctly . Below are listed three kinds of Safety Cautions and Suggestions. W ARNING! CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences. Incorrect operations may result in severe consequen ...

  • Haier AB212XCEAA - page 6

    4 CAUTIONS! Conditioner should not be used for any other purpose other than air conditioning. Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged. Don't dismantle the outlet ...

  • Haier AB212XCEAA - page 7

    Intr oduction to Spar e Parts 5 Drain Hose Swing fender Refrigerant pipe Cable line Earthing line Air filter Outlet Suction grill (located in the suction grill) In cooling operation, to discharge the water from inside the room. Discharge unit (built in) (located in the outlet) ...

  • Haier AB212XCEAA - page 8

    6 3. Dismantle air filter CAUTION! 4. Clean 6. Close inlet grill 7. Press the filter signal return key on the controller . (A) Remove dust with vacuum filter . 5. Install air filter (1) Put filter into protruding parts at the top of the inlet grill. (2) Connect the two pothooks with inlet grill See 2 [Clean inlet grill] 1. Open inlet grill See 1. C ...

  • Haier AB212XCEAA - page 9

    Maintenance 7 3. T ake of inlet grill 4. Clean CAUTION! NOTE When the filter too much dust T o spray the special detergent for vent fan or utensils. 5. Install inlet grill 6. Install air filter 7. Close inlet grill [Clean outlet and shell] see 3 see "Clean air filter" see 1 CAUTION! Don't use gasoline, benzene, dilutant, polishing po ...

  • Haier AB212XCEAA - page 10

    8 NOTE The inner part of indoor unit must be cleaned. Consult dealer , because clean must be done by technician. In cooling operation, discharging system discharge water in r oom. 2. 1. Seasonal Reserve Operate the unit with F AN mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply ...

  • Haier AB212XCEAA - page 11

    9 The followings are not malfuncition Hua Hua T r ouble Shooting W ater flowing sound is heard When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction. Cracking s ...

  • Haier AB212XCEAA - page 12

    10 **? ON OFF T r ouble Shooting Air does not blow or the fan speed cannot be changed during drying. In DR Y mode, when room temperature becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of F AN setting During heating,indoor fan is still running even unit is stopped. T o get ride of the excess heat, in ...

  • Haier AB212XCEAA - page 13

    1 1 When T rouble Happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Horizontal swing louver upward ? (in HEA T mode) Any obstacle exists at the air inlet or outlet? Door or window left opened ? Insufficient cooling Any other heat sources in the room? Sunlight direct into the room ? T oo cro ...

  • Haier AB212XCEAA - page 14

    12 Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner . Please keep the installation manual for future reference when maintenance and changing ...

  • Haier AB212XCEAA - page 15

    13 W ARNING ! CAUTION ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air -conditioner . Air -conditioner can't be installed in the envi ...

  • Haier AB212XCEAA - page 16

    14 Unit shall be grounded. But grounding shall not be connected to gas pipe water pipe, telephone line. Poor grounding will cause electric shock. Be sure to install a leakage breaker to avoid electric shock. Arrange water drainage according to this Manual. Cover pipe with insulation materials in case dew may occur . Unproper installation of water d ...

  • Haier AB212XCEAA - page 17

    15 Installation tools 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner ,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7. Pipe expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 1 1. Band tape 12. Scraper 13. Refrigerant oil The installation tools listed in the following sheet can b ...

  • Haier AB212XCEAA - page 18

    3. PREP ARA TION FOR THE INST ALLA TION (1) Position of ceiling opening between unit and suspending bolt. 3 16 (2) Cut an opening in ceiling for installation if necessary . (when ceiling already exists.) (3) Install a suspending bolt. (Use a M10 bolt) T o support the unit weight, anchor bolt shall be used in the case of already exists ceiling. For ...

  • Haier AB212XCEAA - page 19

    17 4. INST ALLA TION OF INDOOR UNIT In the case of new ceiling < After installation on the ceiling > (3) Adjust unit to its right position. (Refer to preparation for the installation-(1)) (4) Check unit's horizontal level. W atert pump and flating switch is installed inside indoor unit, check four corners of the unit for its level using ...

  • Haier AB212XCEAA - page 20

    6. INST ALLA TION OF W A TER DRAINAGE PIPE ( As for outdoor piping, please refer to installation Manual of outdoor unit. ) 5. REFRIGERANT PIPING Outdoor is precharged with refrigerant. Be sure to see the Fig.1, when connecting and removing piping from unit. For the size of the flare nut, please refer to T able 1. Apply refrigerant oil at both insid ...

  • Haier AB212XCEAA - page 21

    (2) Check if water drainage is smooth after installation. Charge, through air outlet or inspecting hole, 1200ccd water to see water drainage. After wiring Remove cover of control box, short connect "CHECK" terminal of the indoor unit, which is on the uper part of indoor unit PCB. Connect 1PH power to terminal 1 and 2 on terminal block. No ...

  • Haier AB212XCEAA - page 22

    20 As for outdoor unit circuit, please see Installation Manual of outdoor unit. Note: All electric wires have their own poles, poles must match that on terminal block. 9. INST ALLA TION OF ORNAMENT P ANEL 1. Prepar e ornament panel Handling of ornament panel Ornament panel shall not be placed face down or against wall, neither on an uneven object. ...

  • Haier AB212XCEAA - page 23

    21 (1) 3. Install ornament panel on indoor unit. As shown in Fig . 7, match the position of swing flap motor with that of the indoor unit piping hole , so that ormament panel can be placed on to indoor unit. Installation of ornament panel Place the holding ring on swing flao motor side teporarily on hooks of the indoor unit. (2 pcs) Put the other t ...

  • Haier AB212XCEAA - page 24

    22 Item to the checked Pay special care to the following and check after installation Unproper installation may cause Check Is indoor unit firmly installed? Is gas leakage check performed? Is unit properly insulated? Is water drainage smooth? Is power voltage meet that stipulated on the nameplate? Is wiring and piping correctly arranged? Is unit sa ...

  • Haier AB212XCEAA - page 25

    Installation Pr ocedur e After electric installation,power on them to do electric leakage test. The electric wiring work shall be conducted by qualified electricians according to the installation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring will cause danger of electric shock or fire. Dur ...

  • Haier AB212XCEAA - page 26

    Wir e connection for built-in indoor unit Insert from outside the connection wire and signal transmission wire through the wall hole with pipeline already arranged. Pull out the front ends of connection wire and signal wire and make a circle on the signal wire. Connect the connection wire according to the connection method and indoor and outdoor wi ...

  • Haier AB212XCEAA - page 27

    Failur e code The remote receiver can indicate the failure code 25 For remote type, flash times 10 1 2 3 4 5 6 7 8 9 1 1 14 15 16 17 18 19 20 21 22 Failure code on wired control ler 08 01 02 4A 49 48 53 47 07 06 0B 4C 05 54 50 0C 4B 4D 32D 54D For central control, failure code 21 01 02 1 1 12 10 14 22 06 05 30 15 17 26 15 23 18 15 07 08 Failure des ...

  • Haier AB212XCEAA - page 28

    HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden ,Qianwangang Road , Economic Development Zone, Qingdao ,Shandong 266500, P .R.C W eb Site: http://www .haier .com ...

メーカー Haier カテゴリー Air Conditioner

Haier AB212XCEAAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AB212XCEAAの取扱説明書
- Haierの製品カード
- パンフレット
- またはHaier AB212XCEAAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Haier AB212XCEAAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Haier AB212XCEAAの取り付け説明書、サービスマニュアル、簡易説明書、またはHaier AB212XCEAAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Haier AB212XCEAAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Haier AB212XCEAAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHaier AB212XCEAAを使用するのを助ける技術的文書のことです。説明書は通常、全てのHaier AB212XCEAAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Haierの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Haier AB212XCEAAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHaier AB212XCEAAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Haier AB212XCEAAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Haier AB212XCEAAデバイスの基本機能を使うにあたってのヒント。 Haier AB212XCEAAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Haier AB212XCEAAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHaier AB212XCEAAのメーカー/サービスへの連絡先に関する情報。

Haier AB212XCEAAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHaier AB212XCEAAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHaier AB212XCEAAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)