GE RPN2511Eの取扱説明書

22ページ 0.38 mb
ダウンロード

ページに移動 of 22

Summary
  • GE RPN2511E - page 1

    GE Healthcare Amersham Hybridization oven/shak er Pr oduct User Manual Codes: RPN2510E RPN2511E RPN2512E ...

  • GE RPN2511E - page 2

    RPN2510EUM Pagefinder Rev C 06/2007 2 Page finder 1. Legal 3 2. Introduction 4 3. Safety warnings and precautions 5 3.1. Electrical Installation 5 4. Specification 6 5. Setting up the Hybridization O ven/Shak er 7 5.1. Setting the oven temperature 7 5.2. Setting up the rotisserie 7 5.3. Setting up the platform shaker 8 6. Hybridization using the pl ...

  • GE RPN2511E - page 3

    1. Legal GE, imagination at work and GE monogram are trademarks of General Electric Company. Amersham, Alkphos Direct , ECF , ECL , ECL Plus, ECL Advance, Hybond, Hypercassette, Hyperfilm, Hyperscreen, Hyper torch, Megaprime, Nick, Rapid- hyb, Ready-To-Go , Rediprime, Sensitive and Trackertape are trademarks of GE Healthcare companies. All third pa ...

  • GE RPN2511E - page 4

    2. Intr oduction One of the most widely used techniques in the molecular biolog y field is the immobilization of DNA and RNA onto a solid suppor t membrane and subsequent hybridizations with a specific single stranded probe, labeled to facilitate its detection. Using the GE Healthcar e Hybridization O ven/Shaker ensures that the temperature and sha ...

  • GE RPN2511E - page 5

    3. Safety w arnings and pr ecautions If the equipment is not used in the manner described in this manual the protection provided might be impaired This equipment is designed to operate under the following conditions: - For indoor use only Use in a well ventilated area Ambient temperature range + 5°C to + 40°C Altitude to 2000 m Relative humidity ...

  • GE RPN2511E - page 6

    4. Specification Overall dimensions Height: 17” (43.5 cm) Depth: 15” (38.0 cm) Width: 15” (38.0 cm) Oven dimensions Height: 8” (20.0 cm) Depth: 9” (23.0 cm) Width: 10” (25.0 cm) Weight: 24 kg Capacity (nominal): 18 litres T emperature range: Ambient plus 5°C–80°C T emperature precision: +/- 0.5°C T emperature f luctuation: +/- 0.1? ...

  • GE RPN2511E - page 7

    5. Setting up the Hybridization O ven/Shaker RPN2510EUM Chapter 5 Rev C 06/2007 7 Fig 1. Diagram of instrument control panel Rotisserie/shaker controls 1. Rotisserie/shaker ON/OFF button 2. Rotisserie/shaker speed selector dial 3. Motor on indicator Temperatur e controls 4. Temperature on/off button 5. Press to set button 6. LED temperature display ...

  • GE RPN2511E - page 8

    4. Place the rotisserie into the oven onto the rotation mechanism, ensuring that the serrated bands at either end of the rotisserie locate onto the steel cogs of the rotation mechanism at the rear of the oven. (B on figure 2). The plastic flanges of the r otisserie locate on to the small wheels on the oven floor . Close the oven door . 5. Ensure th ...

  • GE RPN2511E - page 9

    RPN2510EUM Chapter 6 Rev C 06/2007 9 6. Hybridization using the platform shaker The Hybridization Oven/Shaker is compatible with the hybridization technologies available from GE Healthcare. These include radioactive hybridizations using Rapid hyb buffer and the range of non-radioactive systems for the labelling and detection of proteins and nucleic ...

  • GE RPN2511E - page 10

    RPN2510EUM Chapter 7 Rev C 06/2007 10 Several advantages are associated with performing hybridizations in bottles, namely those of safety and economy as outlined in the introduction. However , the use of bottles for hybridizations and washing procedures requires certain adaptations to standard protocols. 7.1. Assembly of membranes into bottles 1. A ...

  • GE RPN2511E - page 11

    RPN2510EUM Chapter 7 Rev C 06/2007 11 4. Prehybridize the membrane for the specified length of time at a rotisserie speed of 4 rpm. 5. Following prehybridization, turn off the rotisserie, remove the rotisserie from the oven. Add the labeled probe to the buffer , either by removing an aliquot of the buffer , adding the probe and returning the aliquo ...

  • GE RPN2511E - page 12

    RPN2510EUM Chapter 8 Rev C 06/2007 12 8. Maintenance/car e/cleaning of the oven/shak er The GE Healthcare Hybridization Oven/Shaker is designed to provide trouble-free operation. The base of the oven and the shaker tray act as a spills tray and will contain any spillage that occurs during hybridization and washing procedur es. T o ensure lasting op ...

  • GE RPN2511E - page 13

    RPN2510EUM Chapter 9 Rev C 06/2007 13 Symptom 1. Membrane curling up in hybridization bottle 2. High background 3. Weak signal 4. Pat chy backgrounds 5. High background around edge of membrane Cause 1.1. Incorrect orientation of bottle in rotisserie 2.1. Probe concentration too high 2.2. Unincorporated 32 P nucleotides not removed 2.3. Insufficient ...

  • GE RPN2511E - page 14

    Appendix 1. Pr oducts for electr ophor esis DNA Markers Precise Sizing Digest of Natural DNAs 50 Base-pair 100 Base-pair KiloBase DRigest III ladder ladder DNA marker 27-4060-01 27-4005-01 27-4007-01 27-4004-01 500 a 2000 a 10000 23130 b 450 1900 8000 9416 400 1800 6000 6557 350 1700 5000 4361 b 300 1600 4000 2322 250 1500 3000 2027 200 1400 2500 1 ...

  • GE RPN2511E - page 15

    Appendix 2. Hybond membranes for nucleic acid applications Size Pack size Hybond N+ Hybond XL Hybond N Hybond NX Hybond ECL Hybond C Extra Hybond P 82 mm 50 discs RPN82B RPN82S RPN82N RPN82T RPN82D RPN82E 87 mm 50 discs RPN87B RPN87S RPN87N RPN87T 132 mm 50 discs RPN132B RPN132S RPN132N RPN132T RPN132D 137 mm 50 discs RPN137B RPN137S RPN137N RPN137 ...

  • GE RPN2511E - page 16

    Appendix 3. Radioactive labeling systems Labelling T echnology Nucleotide Amount of Labelling Probe specific Recommended Product system template time activity application code (dpm/µg) Rediprime ™ II Random-prime dCTP only 25 ng 10 minutes 2 × 10 9 membrane RPN1633 hybridization RPN1634 Ready-T o-Go ™ Random-prime dCTP only 10 ng–1 µg 5 mi ...

  • GE RPN2511E - page 17

    Appendix 4. Non-radioactive labeling and detection systems Labelling and detection Sensitivity Time from Duration of Strip before Quantification Recommended application system hybridization light output re-pr obing to detection AlkPhos Direct (RPN3690) 0.06 pg 1 hour 5 days yes no Single copy Southern and Northerns ECL Direct (RPN3000) 0.5 pg 1 hou ...

  • GE RPN2511E - page 18

    Appendix 5. Pr oducts for autoradiography and chemiluminscent detection Hyperfilm – high performance autoradiography films Product description size number sheets code Hyperfilm ECL 5 × 7 inches 50 28-9068-35 Hyperfilm ECL 18 × 24 cm 50 28-9068-36 Hyperfilm ECL 18 × 24 cm 100 28-9068-37 Hyperfilm ECL 8 × 10 inches 50 28-9068-38 Hyperfilm ECL 8 ...

  • GE RPN2511E - page 19

    Appendix 6. Hybridization buffer Product name Pack size Code Rapid-Hyb buffer Rate enhanced hybridization buffer 125 ml RPN1635 for use with radiolabelled nucleic acid probes 500 m RPN1636 RPN2510EUM Appendix 6 Rev C 06/2007 19 ...

  • GE RPN2511E - page 20

    Appendix 7: Radiation safety pr oducts Product Description Product Dimensions Quantity Code Number CDC storage box 240 × 140 × 130 mm 1 box RPN2032 Pipette guards Beta pipette guard, Gilson P20/100 1 guard RPN1544 Beta pipette guard, Gilson P200 1 guard RPN1545 Beta pipette guard, Gilson P1000 1 guard RPN1546 Multipack, 1 each of the above codes ...

  • GE RPN2511E - page 21

    21 ...

  • GE RPN2511E - page 22

    RPN2510EUM Rev C 06/2007 imagination at work GE Healthcare offices: GE Healthcare Bio-Sciences AB Björkgatan 30, 751 84 Uppsala, Sweden GE Healthcare Europe GmbH Munzinger Strasse 5, D-79111 Freibur g, Germany GE Healthcare Bio-Sciences Corp. 800 Centennial Avenue, P .O . Box 1327, Piscataway, NJ 08855-1327, USA GE Healthcare Bio-Sciences KK Sanke ...

メーカー GE カテゴリー Oven

GE RPN2511Eのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RPN2511Eの取扱説明書
- GEの製品カード
- パンフレット
- またはGE RPN2511Eの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、GE RPN2511Eの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、GE RPN2511Eの取り付け説明書、サービスマニュアル、簡易説明書、またはGE RPN2511Eのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、GE RPN2511Eの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

GE RPN2511Eデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGE RPN2511Eを使用するのを助ける技術的文書のことです。説明書は通常、全てのGE RPN2511Eユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

GEの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. GE RPN2511Eの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGE RPN2511Eの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。GE RPN2511Eに関してこのドキュメントで見つけることができる全てのヒントの目次
3. GE RPN2511Eデバイスの基本機能を使うにあたってのヒント。 GE RPN2511Eのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。GE RPN2511Eに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGE RPN2511Eのメーカー/サービスへの連絡先に関する情報。

GE RPN2511Eについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGE RPN2511Eの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGE RPN2511Eで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)