Sanyo SPW-UMR74EXH56 - page 1
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SM940046 SPW-UMR94EXH56 854.0.2264 SPW-UMR224EXH56 854.0.2267 0.8180.439.0 June 2005 SPW-UMR124EXH56 SPW-UMR164EXH56 SPW-UMR184EXH56 854.0.2266 Model No. Product Code No. SPW-UMR74EXH56 854.0.2301 854.0.2263 854.0.2265 ...
-
Sanyo SPW-UMR74EXH56 - page 2
IMPORT ANT! Please read before installation This air conditioning system meets strict safety and operating standards. For the installer or service person, it is important to install or service the system so that it operates safely and efficiently . For safe installation and trouble-free operation, you must: • Carefully read this instruction bookl ...
-
Sanyo SPW-UMR74EXH56 - page 3
Page 1. SPECIFICATIONS 4 1-1 Unit specifications 4 1-2 Major Component specifications 7 1-3 Other Component specifications 10 2. DIMENSIONAL DATA 11 3. ELECTRICAL DATA 13 3-1 Electric Wiring Diagram 13 3-2 Control PCB switches and functions 14 4. FUNCTION 15 4-1 Room Temperature Control 15 4-2 Automatic control for heating and cooling 16 5. REPLACI ...
-
Sanyo SPW-UMR74EXH56 - page 4
1. SPECIFICATIONS 1-1 Unit Specifications SPW-UMR74/94/124EXH56 Power source V olta g e ratin g Performance Capacity Air circulation (High/Med./Low) m³/h Features Controls/Temperature controls Remote Controller (Option) wired wireless Fan speed Air Filter Sound pressure level (*) high/med/low dB(A) Refrigerant tubing connections Refrigerant Narrow ...
-
Sanyo SPW-UMR74EXH56 - page 5
SPW-UMR164/184EXH56 Power source V olta g e ratin g Performance Capacity Air circulation (High/Med./Low) m³/h Features Controls/Temperature controls Remote Controller (Option) wired wireless Fan speed Air Filter Sound pressure level (*) high/med/low dB(A) Refrigerant tubing connections Refrigerant Narrow tube mm(in.) tube diameter Wide tube mm(in. ...
-
Sanyo SPW-UMR74EXH56 - page 6
SPW-UMR224EXH56 Power source V olta g e ratin g Performance Capacity Air circulation (High/Med./Low) m³/h Features Controls/Temperature controls Remote Controller (Option) wired wireless Fan speed Air Filter Sound pressure level (*) high/med/low dB(A) Refrigerant tubing connections Refrigerant Narrow tube mm(in.) tube diameter Wide tube mm(in.) Re ...
-
Sanyo SPW-UMR74EXH56 - page 7
1-2 Major Component Specifications SPW-XMR74/94/124EXH56 Controller PCB Part No. Controls Fan & Fan Motor Type Q'ty ……. Dia. and lenght mm Fan motor model…Q'ty No. Of poles…rpm (230 V, High) Running Amps A Power input W Coil resistance (Ambient temp. 20 °C ) Ω BLU-BRN: 95 BRN-BLK: 37 BLK-GRY: 15 GRY-VLT: 15 WLT-RED: 30 RED- ...
-
Sanyo SPW-UMR74EXH56 - page 8
SPW-XMR164/184EXH56 Controller PCB Part No. Controls Fan & Fan Motor Type Q'ty ……. Dia. and lenght mm Fan motor model…Q'ty No. Of poles…rpm (230 V, High) Running Amps A Power input W Coil resistance (Ambient temp. 20 °C ) Ω BLU-BRN: 68 BRN-BLK: 9 BLK-GRY: 36 GRY-VLT: 18 VLT-RED: 18 BRN-YEL: 105 Safety devices Type Operating ...
-
Sanyo SPW-UMR74EXH56 - page 9
SPW-XMR224EXH56 Controller PCB Part No. Controls Fan & Fan Motor Type Q'ty ……. Dia. and lenght mm Fan motor model…Q'ty No. Of poles…rpm (230 V, High) Running Amps A Power input W Coil resistance (Ambient temp. 20 °C ) Ω BLU-BRN: 68 BRN-BLK: 9 BLK-GRY: 36 GRY-VLT: 18 VLT-RED: 18 BRN-YEL: 105 Safety devices Type Operating tem ...
-
Sanyo SPW-UMR74EXH56 - page 10
1-3 Other Component Specifications Trasformer Rating Primary Secondary 1 Secondary 2 Secondary 3 Thermal cut-off temp. Thermistor ( Coil sensor E1, E2 ) Resistance k Ω Thermistor ( Coil sensor E3 ) Resistance k Ω Thermistor ( Room sensor TA, TF/BL ) Resistance k Ω Drain pump Model Rating Voltage Input Flow rate Safet y float switch Model Cont ...
-
Sanyo SPW-UMR74EXH56 - page 11
2. DIMENSIONAL DATA SPW-UMR74/94/124EXH56 11 ...
-
Sanyo SPW-UMR74EXH56 - page 12
SPW-UMR164/184/224EXH56 12 ...
-
Sanyo SPW-UMR74EXH56 - page 13
3. ELECTRICAL DATA 3-1 Electric Wiring Diagram 7P terminal board 1(L) 2(N) U1 U2 R1 R2 w i r i ng remote con t ro ll e r power supp ly inter-unit con t ro l 13 ...
-
Sanyo SPW-UMR74EXH56 - page 14
3-2 Control PCB switches and functions CR-TRP50A-B OC (CN040) EMG (CN044) VARISTOR (VA041) JP1 DISP (CN072) EXCT (CN073) FILTER (JP001) (CN070) CHK (CN071) FAN DRIVE GRL (CN032) (CN020) T10 (CN061) POWER LED (D002) EEPROM (IC010) T10: 6 plug (yellow): used for remote control. (Refer to the remote control section) (CN061) 1 - start/stop input 2 - CO ...
-
Sanyo SPW-UMR74EXH56 - page 15
4. FUNCTIONS 4-1 Room temperature control 15 ...
-
Sanyo SPW-UMR74EXH56 - page 16
4-2 Automatic control for heating and cooling 16 ...
-
Sanyo SPW-UMR74EXH56 - page 17
5. REPLACING PCB 5-1 Replacing PCB About EEPROM (Erasable Programmable Read-Only Memory) EEPROM is a component in which the various information necessary for functionning can be electronically written or erased. This component holds informations that is essential for the running of the unit, and must be handled with care. D002 led lamp (red) 17 ...
-
Sanyo SPW-UMR74EXH56 - page 18
5-2 How to replace PCB 18 ...
-
Sanyo SPW-UMR74EXH56 - page 19
5-3 How to replace EEPROM with EEPROM included in PCB service pack 19 ...
-
Sanyo SPW-UMR74EXH56 - page 20
20 ...
-
Sanyo SPW-UMR74EXH56 - page 21
5-4 Table of settings 21 ...
-
Sanyo SPW-UMR74EXH56 - page 22
6. SERVICING AND MAINTENANCE FUNCTIONS 22 ...
-
Sanyo SPW-UMR74EXH56 - page 23
7. TROUBLE DIAGNOSIS 7-1 Contents of remote controller switch alarm display 23 ...
-
Sanyo SPW-UMR74EXH56 - page 24
24 ...
-
Sanyo SPW-UMR74EXH56 - page 25
7-2 Outdoor unit control panel LED display 25 ...
-
Sanyo SPW-UMR74EXH56 - page 26
7-3 Trouble indications and inspection points 26 ...
-
Sanyo SPW-UMR74EXH56 - page 27
27 ...
-
Sanyo SPW-UMR74EXH56 - page 28
7-4 Remote controller servicing functions 28 ...
-
Sanyo SPW-UMR74EXH56 - page 29
7-5 Super W-Multi alarm codes 29 ...
-
Sanyo SPW-UMR74EXH56 - page 30
30 ...
-
Sanyo SPW-UMR74EXH56 - page 31
31 ...
-
Sanyo SPW-UMR74EXH56 - page 32
32 ...
-
Sanyo SPW-UMR74EXH56 - page 33
33 ...
-
Sanyo SPW-UMR74EXH56 - page 34
34 ...
-
Sanyo SPW-UMR74EXH56 - page 35
7-6 Inspection of parts 35 ...
-
Sanyo SPW-UMR74EXH56 - page 36
36 ...
-
Sanyo SPW-UMR74EXH56 - page 37
37 ...
-
Sanyo SPW-UMR74EXH56 - page 38
SANYO Airconditioners Europe S.r.l. Via Bisceglie, No.76 20152 Milano, Italy ...