Linak LA35の取扱説明書

20ページ 0.24 mb
ダウンロード

ページに移動 of 20

Summary
  • Linak LA35 - page 1

    LA35 ACTUA TOR T o learn more about LINAK, please visit: WWW .LINAK.COM USER MANUAL ...

  • Linak LA35 - page 2

    2 ...

  • Linak LA35 - page 3

    3 Contents Preface .............................................................................................................................. ................................... 4 Safety instructions .............................................................................................................................. ................ 5 ...

  • Linak LA35 - page 4

    4 Preface We ar e delighted that you have chosen a product from LINAK. LINAK systems ar e high-tech products based on many years of experience in the manufactur e and development of actuators, electronic contr ol boxes, controls, and chargers. We ar e also constantly improving our pr oducts to meet customer requirements. This user manual will tell ...

  • Linak LA35 - page 5

    5 Safety instructions Please read the following safety information car efully . Ensure that all staf f who are to connect, mount, or use the actuator are in possession of the necessary information and that they have access to this user manual. Persons who do not have the necessary experience or knowledge of the product/ products must not use the pr ...

  • Linak LA35 - page 6

    6 Important information Information about the actuators is described under the following two headings: W ar ning! Failing to follow these instructions can cause accidents resulting in serious personal injury . Failing to follow these instructions can result in the actuator suf fering damage or being ruined. ...

  • Linak LA35 - page 7

    7 DECLA RA TION OF CONFORMITY LINAK A/S Smedevænget 8 DK - 6430 Nordborg hereby declares that LINA K Actuator 35xxxxxxxxxxx2x complies with the EMC Directive: 2004/108/EC according to following harmonized standards: EN 61000-4-2:1995+A1+A2, EN 61 000-4-3:2006, EN 61000-4-4:2004, EN 61000-4-5:1995+A1, EN 61000-4-6:19 96+A1, EN 50121-3-2, EN 60204-3 ...

  • Linak LA35 - page 8

    8 Misc. on the TECHLINE TM actuator system W arranty There is a 12 months’ warranty on the TECHLINE pr oducts against manufacturing faults calculated from the pr oduction date of the individual products (see label). LINAK’ s warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tamper ed with. ...

  • Linak LA35 - page 9

    9 Specifications Motor: Permanent magnet motor 12, or 24 * Cable: Motor: 2 x 14 A WG PVC cable Control: 6 x 20 A WG PVC cable ** Housing: The housing is made of casted aluminium, coated for outdoor out and in harsh conditions Spindle part: Outer tube: Powder coated steel Inner tube: Stainless steel AISi304/SS2333 Acme spindle: T rapezoidal spindle ...

  • Linak LA35 - page 10

    Mounting guidelines LINAK ® linear actuators are quickly and easily mounted by slipping pins through the holes on each end of the units and into brackets on the machine frame and the load. The mounting pins must be parallel to each other as shown in Figure 1. Pins, which are not parallel to each other , may cause the actuator to bend and be damage ...

  • Linak LA35 - page 11

    11 Application hints The actuator is weatherproof for use in outdoor applications. The actuator can be washed down with a high pressur e washer , but it should not be used under water . The duty cycle at max. load is 10% on time. This means if the actuator runs continuously for 2 minutes it must remain of f for 18 minutes before operating again. ...

  • Linak LA35 - page 12

    12 Connection diagrams: BROWN BLUE M Basic actuator - Fig.1 : 35xxxxx00xxxxx Electrical installation Be aware of BUS actuator - please see the installation guide. Motor connection Wiring: The actuator direction (forwar d, reverse) is controlled with a doublethr ow switch with the centre postion “of f”. Motor + Actuation T o extend the actuator ...

  • Linak LA35 - page 13

    13 M OUT IN SIGNAL BLACK VIOLET WHITE GREEN YELLOW RED BLUE BROWN Actuator with potential free switches and absolute positioning - Fig.4 : 35xxxxx0Axxxxx & 35xxxxx1Axxxxx M OUT IN BROWN BLUE RED YELLOW GREEN Actuator with potential free switches - Fig.2 : 35xxxxx10xxxxx M OUT IN SIGNAL BLACK VIOLET WHITE GREEN YELLOW RED BLUE BROWN Actuator wit ...

  • Linak LA35 - page 14

    14 BLACK RED YELLOW GREEN WHITE VIOLET INWARDS OUTWARDS ENDSTOP IN ENDSTOP OUT READY DIGITAL/ANALOG PLC OUTPUT BROWN BLUE 12/24V DC M Actuator with PLC-option - Fig.5 : 35xxxxx20xxxxx & 35xxxxx2Hxxxxx & 35xxxxx2Axxxxx ...

  • Linak LA35 - page 15

    15 T roubleshooting Action • Connect the actuator to the power supply • Change cable • Send actuator for repair • Align or reduce load • Send actuator for repair • Send actuator for repair • Send actuator for repair • Change cable • Send actuator for repair • Increase power supply • Thicker cable • Reduce load Possible cause ...

  • Linak LA35 - page 16

    16 Accessories Cables: Power cables (Order ed separately) Order no. 1.5 m cable 0367002-1500 5 m 0367002-5000 0.2 m cable (AMP connectors) 0367006 Signal cable (Order ed separately) Order no. 1.5 m cable 0367003-1500 5 m 0367003-5000 Mounting of cables • Unscrew the cover and r emove the two blind plugs • Plug in the power cable and/or the sign ...

  • Linak LA35 - page 17

    17 LA35 TECHLINE TM LA35: DRA WING APPENDIX 83.5 27 27 233 29 116 54 10.2 10.2 Installation dimension 6.1 17 17 6.1 22 26 11 13 153 STROKE =<300 = 200 + STROKE STROKE >300 = 250 + STROKE Minimum Installation dimension = 300 mm Installation dimension ...

  • Linak LA35 - page 18

    18 Product Metal scrap Cable scrap Electronic scrap Plastic recycling or combustion LA35 X X X X Main groups of disposal Label for LA35 LINAK’ s products may be disposed of, possibly by dividing them into differ ent waste groups for r ecycling or combustion. We r ecommend that our product is disassembled as much as possible at the disposal and th ...

  • Linak LA35 - page 19

    19 LINAK APPLICA TION POLICY The purpose of the application policy is to defi ne ar eas of responsibilities in relation to applying a LINAK product defi ned as hardwar e, software, technical advice, etc. related to an existing or new customer application. LINAK products as defi ned above are applicable for a wide range of applications within the ...

  • Linak LA35 - page 20

    Copyright © LINAK . 2011.04 . MA-M9-02-246-B . LINAK A/S reserves the right to make technical alterations T erms of use The user is responsible for determining the suitability of LINAK products for specifi c application. LINAK takes great care in providing accurate and up-to-date information on its products. However , due to continuous developmen ...

メーカー Linak カテゴリー Automobile Parts

Linak LA35のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LA35の取扱説明書
- Linakの製品カード
- パンフレット
- またはLinak LA35の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Linak LA35の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Linak LA35の取り付け説明書、サービスマニュアル、簡易説明書、またはLinak LA35のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Linak LA35の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Linak LA35デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLinak LA35を使用するのを助ける技術的文書のことです。説明書は通常、全てのLinak LA35ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Linakの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Linak LA35の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLinak LA35の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Linak LA35に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Linak LA35デバイスの基本機能を使うにあたってのヒント。 Linak LA35のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Linak LA35に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLinak LA35のメーカー/サービスへの連絡先に関する情報。

Linak LA35についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLinak LA35の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLinak LA35で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)