Lifebreath 95MAXの取扱説明書

32ページ 1.08 mb
ダウンロード

ページに移動 of 32

Summary
  • Lifebreath 95MAX - page 1

    ® CLEAN • FRESH • AIR * LEA VE FOR HOMEOWNER NOTE: Due to ongoing research and product development, specifications, ratings and dimensions are subject to change without notice. TI-84R-NE 0112 Installing Contractor Telephone / Contact Serial Number Installation Date Model TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION OPERA TION AND INST ALLA ...

  • Lifebreath 95MAX - page 2

    2 T able of Content s Introduction................... ...... .......................................... 2 W arranty ....................................................................... 2 ERV Questions & Answers .......................................... 3 Climate Map ................................................................. 4 T echni ...

  • Lifebreath 95MAX - page 3

    3 ER V Questions & Ans wers What is the difference between an HRV and an ERV? The core in an HRV (Heat Recovery Ventilator) transfers heat from one air stream to the other. This is called sensible heat . The term ERV (Energy Recovery Ventilator) is usually used to describe a unit with an enthalpic core that transfers moisture as well as heat fr ...

  • Lifebreath 95MAX - page 4

    4 ...

  • Lifebreath 95MAX - page 5

    5 Removably Heat Recovery Core Drain Pan Drain spout FRONT TOP knockout for side mounting of EXHAUST return port 6" round collar converted to oval minimum 18 inches (459 mm) required for service access Threaded inserts (4) at corners SUPPLY Fresh air from outside 5" round collar SUPPLY Fresh air to building 6" round (conv. to oval) c ...

  • Lifebreath 95MAX - page 6

    6 DATE: __________________________ PROJECT: __________________________________________ MECHANICAL CONTRACTOR: _____________________________ Model 155MAX ENGINEERING DA T A THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for cleaning or service. MOTORS AND ...

  • Lifebreath 95MAX - page 7

    7 PERFORMANCE HVI CERTIFIED Net supply airflow in cfm (L/s) against external static pressure E.S.P cfm L/s @ 0.1” (25 Pa) 232 (109) @ 0.2” (50 Pa) 223 (105) @ 0.3” (75 Pa) 215 (102) @ 0.4” (100 Pa) 195 (92) @ 0.5” (125 Pa) 189 (89) Maximum Temperature Recovery 81% Sensible Effectiveness @ 117 cfm (55 L/s) (CSA C439M) 74% Sensible Efficien ...

  • Lifebreath 95MAX - page 8

    8 Model MAX TOP ENGINEERING DA T A THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for cleaning or service. MOTORS AND BLOWERS - Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan operation. 120 VAC, 1.4 Amps. FILTERS - W ...

  • Lifebreath 95MAX - page 9

    9 Model 195DCS 49 " (1245) ST ALE AIR TO OUTSIDE FRESH AIR TO INSIDE 14 3/4" (375) 19" (483) Ports  7" (178 mm) CONDENSATE DRAINS BLOWERS *NOTE:  Front clearance  of 25 inches (635 mm)  is recommended  for servicing unit. MOTOR FRESH AIR FROM OUTSIDE ST ALE AIR FROM INSIDE FILTER DEFROST DAMPER DEFROST AIR FROM IN ...

  • Lifebreath 95MAX - page 10

    10 Model 300DCS 49 " (1245) ST ALE AIR TO OUTSIDE FRESH AIR TO INSIDE 14 3/4" (375) 19" (483) Ports  7" (178 mm) CONDENSATE DRAINS BLOWERS *NOTE:  Front clearance  of 25 inches (635 mm)  is recommended  for servicing unit. MOTOR FRESH AIR FROM OUTSIDE ST ALE AIR FROM INSIDE FILTER DEFROST DAMPER DEFROST AIR FROM I ...

  • Lifebreath 95MAX - page 11

    11 Model 200ER V ® CLEAN • FRESH • AIR ENGINEERING DA T A LATENT RECOVERY/MOISTURE TRANSFER CORE The cross-flow energy recovery core transfers heat and water vapour between the two airstreams. It is easily removed for cleaning or service. MOTORS AND BLOWERS - Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan ...

  • Lifebreath 95MAX - page 12

    12 Model 200ER VD ® CLEAN • FRESH • AIR ENGINEERING DA T A LATENT RECOVERY/MOISTURE TRANSFER CORE The cross-flow energy recovery core transfers heat and water vapour between the two airstreams. It is easily removed for cleaning or service. MOTORS AND BLOWERS - Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan ...

  • Lifebreath 95MAX - page 13

    Oper ating the ControlAir 15 Plugging in the HRV/ERV energizes the unit. A self test function will be performed every time the HRV/ERV is energized (refer to “Self Test” for more details). After the self test has completed successfully the HRV/ERV will default to Speed 1. This is the factory default setting. Follow the instructions found on the ...

  • Lifebreath 95MAX - page 14

    14 T o select mode of oper ation for ControlAir 15 Press and hold the fan selection button on the Control Pad. After 5 seconds the control will begin to cycle each mode holding each for 2 seconds. Release the button when the desired mode of operation is reached. Modes of Operation LED Indication OFF No LED’ s illuminated HRV/ER V is off, no contr ...

  • Lifebreath 95MAX - page 15

    15 ControlAir 15 OPTION AL REM OTE CONTROLS 0011 NEW! AIR SENTR Y™ AIR QUALITY SENSOR LOCATION: Kitchen, basement, work place (connect 1/unit only). • Digital Air Quality Monitor. • Status light indicates fan speed. • Increases ventilation to remove odours and contaminants. • Among gases detected are cigarette smoke and formaldehyde. • ...

  • Lifebreath 95MAX - page 16

    16 Some models have a built-in dehumidistat (an optional remote wall mount dehumidistat can be installed, see Optional Remote Controls), to control harmful, excess humidity during the heating season . The dehumidistat operates in % of RH (relative humidity) with 80 being high and 20 being low . The average person is comfortable between 30-45%. The ...

  • Lifebreath 95MAX - page 17

    17 95 MAX Port Specifications The 95 Max Heat Recovery Ventilator (HRV) has been designed to allow the installer to choose between two possible positions on the cabinet for the INDOOR EXHAUST (return from building) port. Illustrations in this manual show standard (side mounted) port location . The same specifications apply to both 95 Max setups, re ...

  • Lifebreath 95MAX - page 18

    18 INS T ALLA TION Location The HRV/ERV must be located in a heated space where it will be possible to conveniently service the unit. Typically the HRV/ERV would be located in the mechanical room or an area close to the outside wall where the weatherhoods will be mounted. If a basement area is not convenient or does not exist, a utility or laundry ...

  • Lifebreath 95MAX - page 19

    INS T ALLING AIR DUCTS A well designed and installed ducting system will allow the HRV/ERV to operate at its maximum efficiency. Always try to keep duct runs as short and straight as possible. See Installation Diagrams for various installation options. Outside W eatherhoods The fixed covered hoods have a built-in bird screen with a 1/4" (6 mm) ...

  • Lifebreath 95MAX - page 20

    20 SUPPL Y AIR DUCTING In homes without a forced air furnace, fresh air should be supplied to all bedrooms and living areas, excluding bathrooms, kitchen and utility areas. It should be supplied from high wall or ceiling locations. Grilles that diffuse the air comfortably such as the Techgrille™ are recommended. If the floor is the only option av ...

  • Lifebreath 95MAX - page 21

    21 DIRECT CONNECTION of the SUPPLY AIR STREAM to the FURNACE COLD AIR RETURN  (Stale air drawn from key areas of home) Forced Air Furnace Outdoors *Unit is normally balanced on HIGH speed  with furnace blower ON. EXHAUST AIR from various parts of home. i.e. bathrooms (if required), kitchens (if required). Cool Air Return NOTES: 1. Furna ...

  • Lifebreath 95MAX - page 22

    22 Simplified Installation Option 1 (Return/Return Method) Note: Option 1 is the pr eferred / r ecommended method when doing a simplified installation. Example diagram only - duct configuration may change depending on model *Unit is normally balanced on HIGH speed  with furnace blower ON. RETURN AIR DIRECT CONNECTION of both the HRV/ERV SUPPL ...

  • Lifebreath 95MAX - page 23

    23 Simplified Installation Option 2 (Supply/Return Method) RETURN AIR DIRECT CONNECTION of both the HRV/ERV SUPPLY AIR STREAM and  EXHAUST AIR STREAM to the FURNACE COLD AIR RETURN & SUPPLY AIR SIDE Outdoors Cool Air Return NOTES: 1. Furnace blower may be required to operate when ventilation from HRV/ERV is required.  The furnace shoul ...

  • Lifebreath 95MAX - page 24

    24 Fully Dedicated System Example diagram only - duct configuration may change depending on model Please Note: It is the responsibility of the installer to ensure all ductwork is sized and installed as designed to ensure the system will perform as intended. All air movement devices have a performance curve. The amount of air (CFM) that an HR V/ERV ...

  • Lifebreath 95MAX - page 25

    25 It is necessary to have balanced air flows in an HRV/ERV. The volume of air brought in from the outside must equal the volume of air exhausted by the unit. If the air flows are not properly balanced, then; • The HRV/ERV may not operate at its maximum efficiency • A negative or positive air pressure may occur in the house • The unit may not ...

  • Lifebreath 95MAX - page 26

    26 Push and turn with slotted screwdriver. Damper automatically locks when pressure is released. When connecting ductwork to the collar, take note where screws are located. Screws should be located no further than 1/2” from outside edge of collar, so as not to impede operation of the damper. 1/2” Hard/Rigid ducting Insulated flexible ducting B ...

  • Lifebreath 95MAX - page 27

    27 1. Inspect Exterior Hoods at least once a month. Make sure exhaust and fresh air supply hoods are not blocked or restricted by leaves, grass, or snow. In winter, it is especially important to make sure snow is not blocking the hoods or that frost has not built up on the wire mesh (bird screen). WARNING: Blockage of hoods may cause an imbalance. ...

  • Lifebreath 95MAX - page 28

    28 1. Inspect Exterior Hoods at least once a month Make sure exhaust and fresh air supply hoods are not blocked up or restricted by leaves, grass, or dirt. WARNING: Blockage of hoods may cause an imbalance. 2. Clean Air Filters Four T imes a Y ear The standard filters equipped with your ERV are removable and washable. a) simply open access door and ...

  • Lifebreath 95MAX - page 29

    S Y MPTOM CA USE SOLUTION Poor Air Flows Supply air feels cold Dehumidistat is not Operating Humidity Levels are too High Condensation is appearing on the windows Humidity Levels are too Low HRV/ERV and / or Ducts Frosting up Condensation or Ice Build Up in Insulated Duct to the Outside Water in the bottom of the HRV/ERV • 1/4” (6 mm) mesh on t ...

  • Lifebreath 95MAX - page 30

    30 T echnical Bulletin When using the ControlAir 15 r elay contacts to initiate blower operation on a furnace, certain thermostats will initiate the outdoor cooling condenser when R and G are closed. Use this wiring configuration to stop the ControlAir15 relay contacts from initializing the condenser unit. This problem can occur at the thermostat b ...

  • Lifebreath 95MAX - page 31

    31 FAN MOTOR GRN T12 T13 CAPACITOR WHITE BLK RED WHITE ORG YEL DIRECT MOUNTED CAPACITOR T9 T10 T11 T12 T13 T14 T5 T4 T3 GROUND DOOR SWITCH WHITE BLACK HIGH VOLTAGE 12V LOW VOLTAGE FIELD INSTALLED LEGEND 12V LOW VOLTAGE GRN Note: If any of the original wire as supplied with the unit must be replaced, use only TEW certified wire P3 AUTO- TRANS FORMER ...

  • Lifebreath 95MAX - page 32

    511 McCormick Blvd. London, Ontario N5W 4 C Ph: (519) 457-1904 Fx: (519) 457-1676 Email: nutech@lifebreath.c o Website: www.lifebreath.co m  ...

メーカー Lifebreath カテゴリー Stereo Amplifier

Lifebreath 95MAXのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 95MAXの取扱説明書
- Lifebreathの製品カード
- パンフレット
- またはLifebreath 95MAXの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Lifebreath 95MAXの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Lifebreath 95MAXの取り付け説明書、サービスマニュアル、簡易説明書、またはLifebreath 95MAXのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Lifebreath 95MAXの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Lifebreath 95MAXデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがLifebreath 95MAXを使用するのを助ける技術的文書のことです。説明書は通常、全てのLifebreath 95MAXユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Lifebreathの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Lifebreath 95MAXの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははLifebreath 95MAXの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Lifebreath 95MAXに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Lifebreath 95MAXデバイスの基本機能を使うにあたってのヒント。 Lifebreath 95MAXのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Lifebreath 95MAXに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるLifebreath 95MAXのメーカー/サービスへの連絡先に関する情報。

Lifebreath 95MAXについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもLifebreath 95MAXの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがLifebreath 95MAXで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)