Sunrise Global 13-05024の取扱説明書

24ページ 0.72 mb
ダウンロード

ページに移動 of 24

Summary
  • Sunrise Global 13-05024 - page 1

    OWNER’S MANUAL CANADIAN ST ANDARDS MINI-SPLIT HEA T PUMP (SEER 16) 12,000 BTU 12,000 BTU COOLING 13,000 BTU HEA TING Before using this air conditioner , please read the following instructions carefully and keep this manual along with your proof of purchase in a safe place for future reference. MODELS: 13-05020 / 13-05024 00228-16/01/07 © Copyrig ...

  • Sunrise Global 13-05024 - page 2

    Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Air conditioner diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Remote control operation . . . . . . . . . . . ...

  • Sunrise Global 13-05024 - page 3

    2 SAFETY PRECAUTIONS Legend of symbols used in this manual : Not to do. Be sure to follow instructions. Grounding is necessary . Feature of the appliance (not a defect). Pay attention. W arning: Incorrect handling may cause serious hazards and/or injuries. Only to the attention of electricians or technicians : T o eliminate risks of short circuits ...

  • Sunrise Global 13-05024 - page 4

    3 AIR CONDITIONER DIAGRAM INDOOR UNIT Air in Display Surface panel Front case Air out Louvers Remote control Drain hose Air in Heating Cooling Auto Power/Run Air out Actual model may differ from the diagram Suction and liquid refrige- rant piping and wiring OUTDOOR UNIT ...

  • Sunrise Global 13-05024 - page 5

    4 REMOTE CONTROL NOTE : • Don’t mix new with used batteries or batteries of different types. • If you are not using the remote control for a long period of time, remove the batteries to eliminate potential battery leakage. • The remote control should be kept at least 1 m or more away from the TV set or any other electric or electronic appli ...

  • Sunrise Global 13-05024 - page 6

    T wo buttons to set the temperature When unit is running under AUTO, COOL, F AN, HEA T , press this button to select the fan speed. AUTO mode, LOW fan, MED fan, HIGH fan. In DEHUMIDIFYING mode the fan speed is set to LOW and cannot be changed. Press this button to select the operation mode desired. AUTO,COOLING,DEHUMI- DIFYING, F AN, HEA T Press cl ...

  • Sunrise Global 13-05024 - page 7

    6 REMOTE CONTROL OPERA TION LIQUID CRYST AL DISPLA Y Show all set functions. ON/OFF Press this key to turn the unit on or off. Press on SWING to start the automatic oscillation of the louvers. Press again to cancel or stop oscillation. Press T -OFF to stop the air conditioner at a desired time. Once pressed, OFF and clock icon will flash. With the ...

  • Sunrise Global 13-05024 - page 8

    7 SAFETY NOTES Always set the most adequate temperature. It is recommend to set the temperature about 5°C cooler than the outside temperature to reduce energy costs. Keep doors and windows closed when the air conditioner is running, otherwise it could affect the air conditioner cooling ef ficiency . Do not splash water or other liquid on the air c ...

  • Sunrise Global 13-05024 - page 9

    8 MAINTENANCE CAUTION T urn power off and then cut the circuit-breaker of f before cleaning the air conditioner . Never spray water on the indoor and outdoor units when cleaning the air conditioner . Always use a dry soft cloth and warm water , without or with a mild detergent. 1. T o remove, pull the front panel in the direction of the arrows. Gen ...

  • Sunrise Global 13-05024 - page 10

    MAINTENANCE 1. Remove the air filters, as described in step #1 of “Cleaning the air filters” section. 2. T ake the active-carbon air filters out of the bag and place them into the filter frames. • Be cautious not cut yourself on the fins. 3. Reinstall the air filters, as described in step #3 of “Cleaning the air filers” section. • If yo ...

  • Sunrise Global 13-05024 - page 11

    10 TROUBLESHOOTING The air conditioner does not run immediately after the power key is pressed on. There is an unusual odour coming out of the air outlet grills when the air conditioner is running. A clicking noise can be heard when the unit is turned on or shut off. Air cooling is not efficient. The remote control does not work. The air conditione ...

  • Sunrise Global 13-05024 - page 12

    11 TROUBLESHOOTING Unusual noise can be heard during operation. Power fuse or switch often breaks. Carelessly splash water or something into air conditioner . Electrical lines and power plug are very hot. Wind blowing from the outlet smells bad during operation. W ater is leaking on the inside wall. Tradex Corp. Tradex Corp. www.sunrisetradex.com 1 ...

  • Sunrise Global 13-05024 - page 13

    12 TECHNICAL SPECIFICA TIONS MODEL FUNCTIONS ACCESSORY COOLING CAP ACITY (W) HEA TING CAP ACITY (W) POWER SUPPL Y FREQUENCY COOLING / HEA TING RA TED CURRENT MAXIMUM INPUT CURRENT COOLING / HEA TING RA TED POWER COOLING / HEA TING RA TED INPUT RECYCLING AIR VOLUME (m 3 /h) REFRIGERANT AND WEIGHT W A TER PROOF LEVEL NOISE (INDOOR / OUTDOOR) dB (A) C ...

  • Sunrise Global 13-05024 - page 14

    13 INST ALLA TION SETUP DIAGRAM Space to the ceiling Space to the wall Space to the wall Insulation tape Air outlet side Space to the cover Air intake side Space to the wall Space to the wall 30cm or more 200cm or more 50cm or more 30cm or more 50cm or more 15cm or more 300cm or more 15cm or more 15cm or more 200cm or more IMPORT ANT NOTES • The ...

  • Sunrise Global 13-05024 - page 15

    14 INST ALLA TION LOCA TION INDOOR UNIT 1. The inlet and outlet should not be covered so that the outflow air can reach all parts of the room. 2. Install in a location where is permitting easy connection with the outdoor unit. 3. A location from which the condensation water can be drained out conveniently . 4. Avoid a location where there is heat s ...

  • Sunrise Global 13-05024 - page 16

    15 INST ALLA TION INSTRUCTIONS INST ALL THE REAR P ANEL 1. Always mount the rear panel horizontally . 2. Fix the rear panel on the selected location with screws supplied with the unit. 3. Be sure that the rear panel has been fixed firmly enough to withstand the weight of an adult of 60 kg (132.3 lbs.), furthermore, the weight should be evenly share ...

  • Sunrise Global 13-05024 - page 17

    16 INST ALLA TION INSTRUCTIONS ELECTRICAL WIRING - INDOOR UNIT *Only an electrician must do the connection of this unit. Note: The power of indoor unit is supplied by the outdoor unit.The outside disconnect switch must be installed between electrical panel and condensing unit. Operation procedures: 1. Open the surface panel. 2. Open the cover and c ...

  • Sunrise Global 13-05024 - page 18

    17 INST ALLA TION INSTRUCTIONS IMPORT ANT NOTICE 1. Wiring should be properly installed. 2. T ighten the screws on the terminal board. 3. Pull on each wire and make sure they are solidly in place. 4. Wrong wiring will cause unit to work abnormally and/or damage the unit. 5. Wrong wire grounding may cause short circuit. Wiring cover T erminal Wire c ...

  • Sunrise Global 13-05024 - page 19

    18 INST ALLA TION INSTRUCTIONS ELECTRICAL WIRING - OUTDOOR UNIT IMPORT ANT NOTICE 1. Wiring should be properly installed. 2. T ighten the screws on the terminal board. 3. Pull on each wire and make sure they are solidly in place. 4. Wrong wiring will cause unit to work abnormally and/or damage the unit. 5. Wrong wire grounding may cause short circu ...

  • Sunrise Global 13-05024 - page 20

    1. When routing the piping and wiring from the left or right side of the indoor unit, cut off the tai - lings from the chassis in neces- sary (shown in Fig.4, (a), (b) (c)). (1) Cut off the tailings 1 when routing the wiring only . (2) Cut off the tailings 1 and tai- lings 2 (or tailings 1, tailings 2 and tailings 3) when routing both the wiring an ...

  • Sunrise Global 13-05024 - page 21

    20 AIR PURGING AND LEAKAGE TEST 1. T ake out the nut cover of the inlet for refrigerant. 2. Connect the tube of the vacuum watch with the vacuum pump, having the low- pressure end linking to the inlet for refri- gerant. 3. Starting the vacuum pump, when the indicator turns to -1 bar , closing the low pressure handle and stopping vacuu- mize. Keep f ...

  • Sunrise Global 13-05024 - page 22

    21 TEST OPERA TION 1. Before test operation (1) Do not switch on power before installation is finished completely . (2) Electric wiring must be connected cor- rectly and securely . (3) Cut-off valves of the connection pipes should be opened. (4) All the impurities such as scraps and thrums must be clear from the unit. (5) Open the surface panel and ...

  • Sunrise Global 13-05024 - page 23

    22 IMPORT ANT NOTICE • Always consult a qualified electrician to install the unit. • Please contact the after sales service for any problems. • If you have to carry your air conditioner in down position, it is suggested to wait 12 hours before you restart the machine. • During winter , it is recommanded to isolate the compressor of the outd ...

  • Sunrise Global 13-05024 - page 24

    LIMITED W ARRANTY This air conditioner is covered by a warranty against defects in materials and workmanship including the compressor , if used for the applications specified in this owner ’s manual, if installed by a Sunrise T radex Corp. certified installer , for a period of ONE (1) year from the date of original purchase in Canada. NOTE: the c ...

メーカー Sunrise Global カテゴリー Electric Heater

Sunrise Global 13-05024のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 13-05024の取扱説明書
- Sunrise Globalの製品カード
- パンフレット
- またはSunrise Global 13-05024の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Sunrise Global 13-05024の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Sunrise Global 13-05024の取り付け説明書、サービスマニュアル、簡易説明書、またはSunrise Global 13-05024のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Sunrise Global 13-05024の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Sunrise Global 13-05024デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSunrise Global 13-05024を使用するのを助ける技術的文書のことです。説明書は通常、全てのSunrise Global 13-05024ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Sunrise Globalの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Sunrise Global 13-05024の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSunrise Global 13-05024の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Sunrise Global 13-05024に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Sunrise Global 13-05024デバイスの基本機能を使うにあたってのヒント。 Sunrise Global 13-05024のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Sunrise Global 13-05024に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSunrise Global 13-05024のメーカー/サービスへの連絡先に関する情報。

Sunrise Global 13-05024についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSunrise Global 13-05024の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSunrise Global 13-05024で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)