    Effective Date 2/2007 For more information visit: www .itvss.com Contents Page 1 Introduction ............................................................................. 1 1.1 Scope ......................................................................... 1 1.2 XT-40 Catalog Numb ering System ............................ 1 1.3 IT-RSS System Wirin ...

  • Eaton IM01005012E - page 2

    IM01005012E XT -40 & IT -RSS Inst allation Page A Rev . 1 – 2/2007 Register Your Warranty On-Line at http://www.itvss.com/ Notice: Product improvements and enhancements are continuous; therefore the specifications and info rmati on contained in this document may change without notice. Eaton Corporation shall not be liable for errors contained ...

  • Eaton IM01005012E - page 3

    XT -40 & IT -RSS Inst allation IM01005012E Rev . 1 – 2/2007 Page 1 1 I NTRODUCTION 1.1 Scope This installation manual contains the inf ormation necessary to install Eaton Corporation’s XT-40 and IT-RSS Surge Protective Devices (SPDs). System wiring and vol tage information for these devices are provided in Sections 1.2 and 1.3. If you requi ...

  • Eaton IM01005012E - page 4

    IM01005012E XT -40 & IT -RSS Inst allation Page 2 Rev . 1 – 2/2007 1.4 Safety Precautions A licensed/qualified electrician must complete all instructions and measurement s described in this instruction in accordance with the U.S. National Electrical Code, stat e and local codes, or oth er applicable country codes. The U.S. National Electrical ...

  • Eaton IM01005012E - page 5

    XT -40 & IT -RSS Inst allation IM01005012E Rev . 1 – 2/2007 Page 3 2 I NST ALLA TION 2.1 Before Inst allation Perform or plan the following before installing the SPD: 1. Locate your electrical system ’s appli cab le wiring diagram in Sections 2.2 & 2.3 2. Verify that your electrical system’s voltage and wiring configuration matche s t ...

  • Eaton IM01005012E - page 6

    IM01005012E XT -40 & IT -RSS Inst allation Page 4 Rev . 1 – 2/2007 2.2 XT -40 W iring Diagrams Single Phase (1P101, 1P201) CIRCUI T INTE RRUPT DEVICE PHASE A GROUND NETURA L or PHASE B Us e Inter rupt D evic e if connected to Phase B NOT Neu t ral XT -40 Split Phase (1S101) CIRCUI T INTERRUP T DEVICE PHASE A NEUTRAL GROUN D PHASE B Soli d bon ...

  • Eaton IM01005012E - page 7

    XT -40 & IT -RSS Inst allation IM01005012E Rev . 1 – 2/2007 Page 5 2.3 IT -RSS W iring Diagram Split Phase – 288 Vac Phase to Phase Max. IT -RSS CIRCUI T INTE RRUP T DEV ICE PHASE A GROU ND PHASE B 2.4 Inst alling Circuit Interrupt Devices The SPD must be connect ed to the electrical sy stem through a 30 A circuit interrupt device as listed ...

  • Eaton IM01005012E - page 8

    IM01005012E XT -40 & IT -RSS Inst allation Page 6 Rev . 1 – 2/2007 2.5 Conduit Inst allation When planning the conduit installatio n, avoid usin g 90° elbows and keep the conduit run a s sh ort and straight as possible. See Figure 2 -1. When applicable, use weatherproof (corrosion resistant) con duit and fittings to maintain the enclosure’ ...

  • Eaton IM01005012E - page 9

    XT -40 & IT -RSS Inst allation IM01005012E Rev . 1 – 2/2007 Page 7 Figure 2-2. XT-40 & IT-RSS Mounting Dimensions 2.40 (61.0) 1.77 (45.0) 3.15 (80.0) 2.4 8 (63.0) 4.1 7 (105.9) 3.2 3 (82.0) 4.73 (120.1) 5.5 8 (141.7) 4.80 (121.9) 3.15 (80.0) 0.25 (6.4) M ounting Ho l e Sh af t s M ounting Hole s Unde r L id (4 ) 0.75 (19.0) In t er n al l ...

  • Eaton IM01005012E - page 10

    IM01005012E XT -40 & IT -RSS Inst allation Page 8 Rev . 1 – 2/2007 2.8 Power Up and System Checkout Apply system power and observe that the LED(s) on the front of the SPD should glow. One L ED should glow for each Phase voltage being monitored. Should there be a significant difference in brightness, check the ph ase rotation of the panel and ...

  • Eaton IM01005012E - page 11

    XT -40 & IT -RSS Inst allation IM01005012E Rev . 1 – 2/2007 Page 9 Notes: ...

  • Eaton IM01005012E - page 12

    Eaton Corporation 1000 Cherrington Park way Moon Township, PA 15108-4312 USA http://www.itvss.com © 2007 Eaton Corporation For additional information please call: All Rights Reserved Power Quality Technical Support Center Publication No. IM0100501 2E 1-800-809-2772 Rev. 1 – February 2007 ...

メーカー Eaton カテゴリー Power Supply

Eaton IM01005012Eのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IM01005012Eの取扱説明書
- Eatonの製品カード
- パンフレット
- またはEaton IM01005012Eの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Eaton IM01005012Eの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Eaton IM01005012Eの取り付け説明書、サービスマニュアル、簡易説明書、またはEaton IM01005012Eのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Eaton IM01005012Eの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Eaton IM01005012Eデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEaton IM01005012Eを使用するのを助ける技術的文書のことです。説明書は通常、全てのEaton IM01005012Eユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Eatonの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Eaton IM01005012Eの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEaton IM01005012Eの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Eaton IM01005012Eに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Eaton IM01005012Eデバイスの基本機能を使うにあたってのヒント。 Eaton IM01005012Eのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Eaton IM01005012Eに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEaton IM01005012Eのメーカー/サービスへの連絡先に関する情報。

Eaton IM01005012Eについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEaton IM01005012Eの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEaton IM01005012Eで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)