    12428-3-0706 Page 1 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL Installer: Leave these instructions with the consumer . Consumer: Retain these instructions for futur e use. W ARNING: If not installed, operated and main- tained in accordance with the manufacturer’ s instructions, this product could expose you to substances in fuel or from fue ...

  • Empire Comfort Systems FAW-55SPP - page 2

    12428-3-0706 Page 2 Introduction Always consult your local Building Department regarding regu- lations or ordinances which apply to the installation of a vented wall furnace. Instructions to Installer 1. Installer must leave instruction manual with owner after instal - lation. 2. Installer must have owner fill out and mail warranty card supplied w ...

  • Empire Comfort Systems FAW-55SPP - page 3

    12428-3-0706 Page 3 SAFETY INFORMA TION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fir es and explosions. In its natural state, propane is odorless and colorless. Y ou may not know all the following safety precau - tions which can protect both you and your family from an accident. Read them carefully now , then r evie ...

  • Empire Comfort Systems FAW-55SPP - page 4

    12428-3-0706 Page 4 V entilation and Combustion Air W all furnaces shall be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions. In buildings of conventional frame, brick, or stone construction without tight storm windows and doors, infiltration is normall ...

  • Empire Comfort Systems FAW-55SPP - page 5

    12428-3-0706 Page 5 8” x 12” (203mm x 305mm) boot. Remove duct and cut to proper length. 8. Attach 6” x 10” (152mm x 254mm) duct to inner casing with (6) #10 x 1/2” (13mm) screws provided. 9. Insert rear register into 8” x 12” (203mm x 305mm) boot. Attach rear register to wall with (2) #10 x 1” (25mm) screws provided. Locating Furna ...

  • Empire Comfort Systems FAW-55SPP - page 6

    12428-3-0706 Page 6 4. Connect nylon cap on 3’ (914mm) plug assembly to nylon plug on the wiring harness. 5. Place 7/8” (22mm) strain relief bushing around the cord of the 3’ (914mm) plug assembly . Insert 7/8” (22mm) strain relief bushing into the 7/8” (22mm) hole in the side panel. Attention! The 7/8” (22mm) strain relief bushing is l ...

  • Empire Comfort Systems FAW-55SPP - page 7

    12428-3-0706 Page 7 T o light the pilot, it is important that the electrode be 1/8” (3mm) from the thermocouple. The spark must occur at the point the burner flame hits the thermocouple. The end of the electrode will be red hot with the pilot on. On a new installation with air in the gas line, it is suggested that a match be used. The match will ...

  • Empire Comfort Systems FAW-55SPP - page 8

    12428-3-0706 Page 8 V ent Safety Shutoff System This appliance must be properly connected to a venting system. This appliance is equipped with a vent safety shutoff system. This furnace is equipped with a manual reset vent safety switch. The manual reset vent safety switch will cause gas flow to the main burners to “shut off” due to improper v ...

  • Empire Comfort Systems FAW-55SPP - page 9

    12428-3-0706 Page 9 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING s ...

  • Empire Comfort Systems FAW-55SPP - page 10

    12428-3-0706 Page 10 Please Note: When ordering parts, it is very important that part number and description of part coincide. Index No. Part Number Description Index No. Part Number Description 1 WF A-115 BASEPLA TE GASKET 28 DV -687 MANIFOLD AND PLA TE ASSEMBL Y 2 1 1763 OUTER CASING T OP 29 712045 MANIFOLD GASKET 3 632024 MOTOR MOUNT (FOUR REQUI ...

  • Empire Comfort Systems FAW-55SPP - page 11

    12428-3-0706 Page 1 1 ...

  • Empire Comfort Systems FAW-55SPP - page 12

    12428-3-0706 Page 12 Model No. F A W -55 may be vented as shown. The vent cap must be at least 12 feet (3.7m) above the floor . Clearance to combus - tible construction is held by the fixed spacers at 1 inch (25mm) with B-1 vent pipe. Installation must conform to local codes. 4” (102mm) Round (all parts purchase locally except in item 2) 1. T y ...

メーカー Empire Comfort Systems カテゴリー Furnace

Empire Comfort Systems FAW-55SPPのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FAW-55SPPの取扱説明書
- Empire Comfort Systemsの製品カード
- パンフレット
- またはEmpire Comfort Systems FAW-55SPPの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Empire Comfort Systems FAW-55SPPの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Empire Comfort Systems FAW-55SPPの取り付け説明書、サービスマニュアル、簡易説明書、またはEmpire Comfort Systems FAW-55SPPのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Empire Comfort Systems FAW-55SPPの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Empire Comfort Systems FAW-55SPPデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがEmpire Comfort Systems FAW-55SPPを使用するのを助ける技術的文書のことです。説明書は通常、全てのEmpire Comfort Systems FAW-55SPPユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Empire Comfort Systemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Empire Comfort Systems FAW-55SPPの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははEmpire Comfort Systems FAW-55SPPの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Empire Comfort Systems FAW-55SPPに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Empire Comfort Systems FAW-55SPPデバイスの基本機能を使うにあたってのヒント。 Empire Comfort Systems FAW-55SPPのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Empire Comfort Systems FAW-55SPPに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるEmpire Comfort Systems FAW-55SPPのメーカー/サービスへの連絡先に関する情報。

Empire Comfort Systems FAW-55SPPについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもEmpire Comfort Systems FAW-55SPPの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがEmpire Comfort Systems FAW-55SPPで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)