    INTELLIGENT LABEL SENSORS OPERA TIONS MANU AL CS2000 & CS2000-QD C S 2 0 0 0 & C S 2 0 0 0 - Q D CS2000 & CS2000-QD CONTROL TECHNOLOGIES 2617 Fremontia Drive San Bernardino, CA 92404 Phone: 877-880-5389 F ax: 877-880-5537 www .con-tech.com ...

  • Contec CS2000-QDCS2000 - page 2

    Table of Contents General Information  Features  Diagram  CS2000 Quick Start  CS2000-QD Quick Start Installation  Mounting  CS2000 Wiring  CS2000-QD Wiring Operation  Label Placement  Push-Button Functions  LED Functions  Operation Features   Output Mode   Light/Dark Operation   Contrast Setting ? ...

  • Contec CS2000-QDCS2000 - page 3

    - 1 - General Information Features: • 10 to 30 VDC input - reverse polarity protected • Fast RISC microprocessor controlled • Easy one touch setup - label sensitivity easily adjusted, to the optimal setting, by  the push of a button • Missing label compensation - outputs a stop pulse even when a label is missing • Level ...

  • Contec CS2000-QDCS2000 - page 4

    - 2 - General Information Yellow LED: Indicates label backing (web) Push-button Red LED: Indicates output state Green LED: Indicates label + label backing Optional 6" Quick Disconnect 4 Pin Male Cable/Connector #8-32 Mounting Holes EASY SETUP WEB OUT LABEL 1. 2. 3. 4. Po si ti on we b und er sen sin g area and hold bu tt on do wn unt il y el l ...

  • Contec CS2000-QDCS2000 - page 5

    - 3 - General Information CS2000 Quick Start: 1.  Connect red wire to supply voltage 2.  Connect black wire to supply common 3.  For NPN Output - connect orange wire to black wire  For PNP Output - connect orange wire to red wire 4.  Connect white wire to your controller - refer to page 6 for wiring diagrams 5.  Turn on power 6. ? ...

  • Contec CS2000-QDCS2000 - page 6

    - 4 - General Information CS2000-QD Quick Start: 1.  Plug the CS2000-QD's male connector into a suitable 4 pin female connector 2.  Connect brown wire to supply voltage 3.  Connect blue wire to supply common 4.  For NPN Output - connect black wire to blue wire  For PNP Output - connect black wire to brown wire 5.  Connect whi ...

  • Contec CS2000-QDCS2000 - page 7

    - 5 - Installation Mounting: The CS2000 comes with 8 mounting holes allowing for many different mounting options. The holes are tapped for #8-32 screws and are 0.31" deep. We suggest using #8-32 x 3/8" stainless steel screws. Some different options are shown below. * To avoid electro-static discharge and sensor malfunction, the CS2000 sho ...

  • Contec CS2000-QDCS2000 - page 8

    - 6 - Installation CS2000 Wiring: The CS2000 comes with an 8' - 4 conductor cable. Refer below for wire designations. RED = 10-30 VDC BLK = Common WHT = Output ORN = NPN / PNP Output Selector Optoisolat or CS2000 RED 10-30V LOAD BLK WHT ORN WHT ORN WHT ORN WHT ORN WHT +5V 5V Logic 1K 1/4W Supply Voltage 12V = 1K 1/4W 24V = 2K 1/4W 12V = 1K 1/4 ...

  • Contec CS2000-QDCS2000 - page 9

    - 7 - Installation CS2000-QD Wiring: The CS2000-QD comes with a 6" quick disconnect M12 - 4 pin male cable/connector (Turck P/N RS4.4T-2). Refer below for wire designations. Pin 1. BRN = 10-30 VDC Pin 2. WHT = Output Pin 3. BLU = Common Pin 4. BLK = NPN / PNP Output Selector Optoisolat or CS2000-QD BRN 10-30V LOAD BLU WHT BLK WHT BLK WHT BLK W ...

  • Contec CS2000-QDCS2000 - page 10

    ACME LABELS ACME LABELS AC ACME LABELS ACME LABELS ACME LABELS ACME LABELS - 8 - Operation Label Placement: For best results, position straight edge of label under the sensing area. Try to avoid sensing on rounded corners or other curved areas. Refer to diagram below. Less than 1 second 1 to less than 5 seconds 5 to less than 10 seconds 30+ seconds ...

  • Contec CS2000-QDCS2000 - page 11

    - 9 - Operation LED Functions:  Yellow - comes on when label backing (web) is under the sensing area  Red - comes on when output is active - NPN sinking or PNP sourcing  Green - comes on when label over label backing is under the sensing area Operation Features:  The CS2000 has 3 different operation features that can be changed to accom ...

  • Contec CS2000-QDCS2000 - page 12

    - 10 - Adjusting Label Sensitivity Overview:  The CS2000 will automatically adjust its label sensitivity, to the optimal setting, by simply depressing a push-button. This adjustment process is referred to as "Easy Setup." It is recommended that the operator adjust the label sensitivity for each new roll of labels due to differences in ...

  • Contec CS2000-QDCS2000 - page 13

    - 11 - Missing Label Compensation Overview:  The CS2000 has the capability to detect a single missing label and output a stop pulse as though the label were present. In order for Missing Label Compensation to function properly the operator must first: a) have Pulse Output selected - see Program Mode (page 12) for more information. b) adjust the ...

  • Contec CS2000-QDCS2000 - page 14

    - 12 - Program Mode Entering Program Mode:  Program Mode is used to change any or all of the Operation Features. To enter Program Mode depress the push-button until the yellow and green LED's begin toggling (30 sec.), then release. The LED's will then output the current set-up configuration (and every 3 sec. thereafter). For example: a ...

  • Contec CS2000-QDCS2000 - page 15

    - 13 - Specifications General: Power Supply..................................................... 10-30 VDC, reverse polarity protected Power Consumption............................................ 50mA max. Output.............................................................. NPN / PNP open collector Output Current.......................... ...

  • Contec CS2000-QDCS2000 - page 16

    - 14 - Specifications Dimensions: CS2000 0.44 11.2 0.625 1.00 25.4 0.625 15.9 79.4 3.125 50.8 15 0.59 2.00 0.22 5.6 0.75 19.1 0.50 12.7 15.9 0.09 Sensing Area 15.9 0.625 76.2 3.00 EASY SETUP WEB OUT LABEL 13.5 0.53 1.00 88.9 3.50 25.4 9.5 0.38 2.4 1. 2. 3. 4. Po si t io n we b und er se nsi ng area and hold bu tt on do wn un ti l y e l lo w L E D c ...

  • Contec CS2000-QDCS2000 - page 17

    - 15 - Cleaning Instructions Cleaning Instructions: 1.  Begin by removing the sensor lid's 4 screws with a 1/16" L wrench. 2.  Gently lift the sensor's circuit board out by grasping the switch and pulling upward. Do not  remove the insulation tape. 3.  Clean the lens of the sensor's photo eye with a clean soft cloth ...

  • Contec CS2000-QDCS2000 - page 18

    - 16 - Warranty Terms & Conditions Warranty:  The CS2000 Label Sensor is warranteed for a period of two (2) years from the time of purchase. Control Technologies guarantees the CS2000 to be free from defects in materials or workmanship, and that, if used correctly will perform within specifications. The warranty covers normal wear and tear, ...

メーカー Contec カテゴリー Stud Sensor

Contec CS2000-QDCS2000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CS2000-QDCS2000の取扱説明書
- Contecの製品カード
- パンフレット
- またはContec CS2000-QDCS2000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Contec CS2000-QDCS2000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Contec CS2000-QDCS2000の取り付け説明書、サービスマニュアル、簡易説明書、またはContec CS2000-QDCS2000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Contec CS2000-QDCS2000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Contec CS2000-QDCS2000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがContec CS2000-QDCS2000を使用するのを助ける技術的文書のことです。説明書は通常、全てのContec CS2000-QDCS2000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Contecの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Contec CS2000-QDCS2000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははContec CS2000-QDCS2000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Contec CS2000-QDCS2000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Contec CS2000-QDCS2000デバイスの基本機能を使うにあたってのヒント。 Contec CS2000-QDCS2000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Contec CS2000-QDCS2000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるContec CS2000-QDCS2000のメーカー/サービスへの連絡先に関する情報。

Contec CS2000-QDCS2000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもContec CS2000-QDCS2000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがContec CS2000-QDCS2000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)