    CRESTRON GREE N LIGHT™ Architectural Dimming Introduction CRESTRON GREEN LIGHT architectural dimming cabi nets co me pre-configure d with GLX a rchitectural dimming and switching modules alrea dy installed. In addition, branch circuit breakers come preinstalled and prewire d to the modules. The c abinets o nly require i nstallation an d wiring of ...

  • Crestron electronic 277 Volt - page 2

    Architectural Dimming CRESTRON GREEN LIGHT™ Physical Description This section shows the ex terior and interior dimens ions of the CRESTRON GREEN LIGHT A rchitectural Dimming cabinet. External Dimensions of CRESTRON GREEN LIGHT Architectural Dimming C abinets W1 W2 Ø 7 16 " (11 mm) MOUNTING HOLES H1 6 1 16 " (154 mm) CONCENTRIC TECHNICA ...

  • Crestron electronic 277 Volt - page 3

    CRESTRON GREEN LIGHT™ Architectural Dimming Interior Dimensions of CRESTRON GREEN LIGHT Architectural Dimming Cabinets (GLE-XXX-Xx2, left; GLE-XXX-Xx4, right) H1 W3 W3 W2 W1 GROUND LUG GROUND BARS SERVICE SCREWDRIVER H1 W3 W3 W3 W3 W1 W5 W4 W2 SERVICE SCREWDRIVER GROUND LUG GROUND BARS Interior Dimensions of CRESTRON GREEN LIGHT Architectural Dim ...

  • Crestron electronic 277 Volt - page 4

    Architectural Dimming CRESTRON GREEN LIGHT™ Installation Observe the following when installing the cabinet: • The cabinet m ust be mounte d by a licensed electrician in accorda nce with all natio nal and local codes. Refer to the diagram below for specific requirem ents. • Allow adequate clearance in front of the cover for servicing. • The ...

  • Crestron electronic 277 Volt - page 5

    CRESTRON GREEN LIGHT™ Architectural Dimming Wiring NOTE: All wiri ng must be i nstalled in acc ordance with all local and nati onal electrical codes. NOTE: Refer to t he torque set tings specified o n pages 6, 7 and 8. CRESTRON GREEN LIGHT cabinets are shippe d with GLX modu les installed and prewired to the branch circuit breakers. The following ...

  • Crestron electronic 277 Volt - page 6

    Architectural Dimming CRESTRON GREEN LIGHT™ Feed Wiring (Section A) Feed Wiring for MLO and MCB Applications MCB BREAKER DETAIL MLO BREAKER DETAIL "A" PHASE "B" PHASE "C" PHASE NEUTRAL LUG NEUTRAL BUS NEUTRAL BUS "A" PHASE "B" PHASE "C" PHASE NEUTRAL LUG GROUND LU G GROUND BA RS GROUND L ...

  • Crestron electronic 277 Volt - page 7

    CRESTRON GREEN LIGHT™ Architectural Dimming Load Wiring (Section B) CAUTION: Bypass jum pers are provided on each output to allow testing an d to protec t the module during installation. The jumper shorts the L , SW and DM terminals so that the load circuit is energized when the bran ch breaker is on. Do not remove the bypass jumper until all fee ...

  • Crestron electronic 277 Volt - page 8

    Architectural Dimming CRESTRON GREEN LIGHT™ The GLX-DIMFLV 8 also requires wiri ng the terminals for 0-10 VDC control wire. Refer to the following diagram when connecting the dimmable ballast. Each control wire terminal accepts one 12 – 28 AWG wire. 0-10 VDC Control Wiring for GLX-DIMFLV8 Only TO "+" ON 4-WIRE LOADS (PURPLE) TO " ...

  • Crestron electronic 277 Volt - page 9

    CRESTRON GREEN LIGHT™ Architectural Dimming Connector Wiring RED WHITE BLUE BLACK RED WHITE BLUE BLACK OVERRIDE: FROM OTHER CABINET; FROM ALARM, ETC. (OPTIONAL); TO OTHER CABINET(S) IF NECESSARY POWER: 24 VDC JUMPERED FROM NET PORT or EXTERNAL SUPP LY. PROVIDES CRESNET POWER TO THE MODULES NET: TO CONTROL SYSTEM A ND OTHER CRESNET DEVICES MODULES ...

  • Crestron electronic 277 Volt - page 10

    Architectural Dimming CRESTRON GREEN LIGHT™ To power the modules ext ernally from a Cresnet 24 VDC p ower supply , connect the external p ower supply to the EXT and G pins on the POWER suppl ied connector as shown in t he followi ng diagram . Providing Cresnet Power Externally When properly connected a nd r eceiving 24 VDC power e xternally, the ...

  • Crestron electronic 277 Volt - page 11

    CRESTRON GREEN LIGHT™ Architectural Dimming Testing Manual Control A lighting module can be manuall y controlle d from its front pa nel. Switch Function The GLX-HSW8 is a power switchi ng module that can be used to tu rn loads on and off. The GLX-DIM 6 and the GLX -DIMFLV8 are dimming m odu les whose outputs can be set to operate as dimmable or n ...

  • Crestron electronic 277 Volt - page 12

    Architectural Dimming CRESTRON GREEN LIGHT™ Save Override Settings The state of each out put can be save d as an override setti ng, which can be automatically recalled when t he Override mode is ena bled. NOTE: The control system program has a setting that can preven t locally saving the override state. If this setting is enabled, the display sho ...

  • Crestron electronic 277 Volt - page 13

    CRESTRON GREEN LIGHT™ Architectural Dimming Problem Solving Troubleshooting The following table prov ides corrective action for po ssible troub le situ ations. If further assistance is requi red, please contact a Crestron custom er service representative. Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTIO N Power not delivered to the modu ...

  • Crestron electronic 277 Volt - page 14

    Architectural Dimming CRESTRON GREEN LIGHT™ Appendix A: Setting Module Net IDs The following procedure will normally be performed by an au thor ized Crestron representative as part of the System Commissioni n g pha se. For system wiri ng and basic test i n g as desc ri be d o n page s 5 and 11, it is not nec essary to perform this step. Only perf ...

  • Crestron electronic 277 Volt - page 15

    CRESTRON GREEN LIGHT™ Architectural Dimming Appendix B: Module Specifications Specifications for the GLXP modules are li sted in the following tabl e. GLXP Module Specification s SPECIFICATION GLX-DIM6 GLX-HSW8 GLX-DIMFLV8 Description 6 Channel Dimming/S witching Module 8 Channel High-Inrush S witch Module 8 Channel 0-10V Fluorescent Dimmer Modul ...

  • Crestron electronic 277 Volt - page 16

    Architectural Dimming CRESTRON GREEN LIGHT™ Return and Warranty Policies Merchandise Returns / Repair Service 1. No mer ch and ise may be r etu rne d for credit, exchange or service without prior authorizatio n fro m CRESTRON. To obtain w arranty service for CRESTRON pr oducts, conta ct an authori zed CRESTRON dealer. Only authori zed CRESTRON de ...

メーカー Crestron electronic カテゴリー Indoor Furnishings

Crestron electronic 277 Voltのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 277 Voltの取扱説明書
- Crestron electronicの製品カード
- パンフレット
- またはCrestron electronic 277 Voltの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Crestron electronic 277 Voltの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Crestron electronic 277 Voltの取り付け説明書、サービスマニュアル、簡易説明書、またはCrestron electronic 277 Voltのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Crestron electronic 277 Voltの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Crestron electronic 277 Voltデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCrestron electronic 277 Voltを使用するのを助ける技術的文書のことです。説明書は通常、全てのCrestron electronic 277 Voltユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Crestron electronicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Crestron electronic 277 Voltの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCrestron electronic 277 Voltの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Crestron electronic 277 Voltに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Crestron electronic 277 Voltデバイスの基本機能を使うにあたってのヒント。 Crestron electronic 277 Voltのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Crestron electronic 277 Voltに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCrestron electronic 277 Voltのメーカー/サービスへの連絡先に関する情報。

Crestron electronic 277 Voltについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCrestron electronic 277 Voltの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCrestron electronic 277 Voltで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)