Extron electronic 200の取扱説明書

18ページ 4.41 mb
ダウンロード

ページに移動 of 18

Summary
  • Extron electronic 200 - page 1

    User Guide Cable Cubby ® 200 Architectur al Connectivity Cable Access Enclosur e 68-1557-01 Rev . A 10 12 ...

  • Extron electronic 200 - page 2

    Safety Instructions • English W ARNING : This symbol, , when used on the product, is intended to alert the user of the presence of uninsulated danger ous voltage within the product’ s enclosure that may pr esent a risk of electric shock. A TTENTION: This symbol, , when used on the pr oduct, is intended to alert the user of important operating a ...

  • Extron electronic 200 - page 3

    Conventions Used in this Guide The following notifications are used: CAUTION: A caution indicates a situation that may result in minor injury . A TTENTION: Attention indicates a situation that may damage or destroy the pr oduct or associated equipment. NOTE: A note draws attention to important information. Specifications Availability: Product speci ...

  • Extron electronic 200 - page 4

    ...

  • Extron electronic 200 - page 5

    v Cable Cubby 200 • Contents Contents Introduction ............................................................ 1 Overview ............................................................ 1 Cable Cubby 200 Features ................................ 1 Kit Contents ........................................................... 2 Included Parts ............ ...

  • Extron electronic 200 - page 6

    Cable Cubby 200 • Introduction 1 Intr oduction Overview The Extron Cable Cubby 200 is a furniture-mounted, ar chitectural solution that provides inconspicuous cable access and connection points. When cables are not in use, they can be stored out of the way while r emaining connected to the presentation system. Lift the lid to access the AAPs and ...

  • Extron electronic 200 - page 7

    Cable Cubby 200 • Kit Contents 2 Kit Contents Included Parts Image Part Quantity Cable Cubby 200 enclosure 1 Cable pass-through AAPs 2 Cable stand-offs 4 Mounting screws (6-32 x 3/4 inch) 4 Grommet and hole plug kit 1 ...

  • Extron electronic 200 - page 8

    Cable Cubby 200 • Before Getting Started 3 Befor e Getting Started This section describes important information about the Cable Cubby 200 and planning considerations for installation. T opics in this section include: • About the Cable Cubby 200 • Planning • T ools and Equipment Required for Installation About the Cable Cubby 200 Fi ...

  • Extron electronic 200 - page 9

    Cable Cubby 200 • Before Getting Started 4 Planning Determine the best location for the enclosure. Befor e making any cuts : • Ensure that the location wher e the Cable Cubby is to be installed is convenient for as many users as possible. • Ensure that the edge on which the lid opens is oriented corr ectly . • Ensure that ther e is ...

  • Extron electronic 200 - page 10

    Cable Cubby 200 • Installation 5 Installation This section provides information for an experienced installer to set up and install the Cable Cubby 200. Before starting, decide wher e to install the Cable Cubby , verify that all included parts are accounted for , and gather the necessary equipment for installation. CAUTION: Risk of injury to the e ...

  • Extron electronic 200 - page 11

    Cable Cubby 200 • Installation 6 1. Prepar e the Routing T emplate NOTE: Save and reuse the metal r outing template for installing additional Cable Cubby 200 models. a. Cut 1/2 inch x 4 inch strips of soft, finished lumber to a length that is long enough to span the edges of the mounting surface. b. Place the template over the strips so that the ...

  • Extron electronic 200 - page 12

    Cable Cubby 200 • Installation 7 1. Plan for AAPs TIP: T ypical installations consist of a VGA (large hole), an audio (small hole), and a network (medium hole) cable. In a non-standard installation, match the diameter of the cable to the size of the hole that best applies. NOTE: Pass-through AAPs can also be replaced by optional passive AAPs for ...

  • Extron electronic 200 - page 13

    Cable Cubby 200 • Installation 8 3. Install Any Necessary Split Grommets and Hole Plugs a. Slip the appropriate split grommet over each cable with the flange of the grommet towar d the connector that will be accessible inside the Cable Cubby . Snap the grommets into the channels. b. If necessary , snap the included hole plugs into unused holes. 4 ...

  • Extron electronic 200 - page 14

    Cable Cubby 200 • Installation 9 Secu re cables w/ zip ties to holes in r ear of Cable Cubby . Power Co rd Connect to AV Device or System 1. T est the Fit a. Remove the plastic strips on finished surfaces of the Cable Cubby . A TTENTION: Potential damage to property . Do no use isopropyl alcohol or other solvents to clean the Cable Cubby . Strong ...

  • Extron electronic 200 - page 15

    Cable Cubby 200 • Reference Information 10 Refer ence Information This section provides part numbers for the Cable Cubby 200 and r elated products. Visit the Extron website, www .extron.com , for more details and part numbers. T opics in this section include: • Enclosure Part Numbers • Included Accessories Part Numbers • Routing T ...

  • Extron electronic 200 - page 16

    Cable Cubby 200 • Reference Information 11 Cable Pass-through AAPs (see figur e 2 ) Part Numbers Cable pass-through (right) 70-267-01 Cable pass-through (left) 70-270-01 Grommet and Plug Kit Part Numbers Grommet and hole plug kit 70-387-01 Routing T emplate Part Numbers The Cable Cubby 200 metal routing template (see figur e 3 ) is the only prefe ...

  • Extron electronic 200 - page 17

    Cable Cubby 200 • Reference Information 12 T op Plate Dimensions If you choose not to use the Extron metal r outing template, the paper cut-out template will help you properly pr epare the mounting surface (see figur e 4 ). The cutout template is not to scale and is for refer ence only . For full size paper templates, visit the Extron website ( w ...

  • Extron electronic 200 - page 18

    Extron Headquarters +1.800.633.9876 (Inside USA/Canada Only) Extron USA - W est Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 F AX +1.919.850.1001 F AX Extron Europe +800.3987.6673 (Inside Europe Only) +31.33.453.4040 +31.33.453.4050 F AX Extron Asia +800.7339.8766 (Inside Asia Only) +65.6383.4400 +65.6383.4664 F AX Extron Japan ...

メーカー Extron electronic カテゴリー Cable Box

Extron electronic 200のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 200の取扱説明書
- Extron electronicの製品カード
- パンフレット
- またはExtron electronic 200の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Extron electronic 200の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Extron electronic 200の取り付け説明書、サービスマニュアル、簡易説明書、またはExtron electronic 200のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Extron electronic 200の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Extron electronic 200デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがExtron electronic 200を使用するのを助ける技術的文書のことです。説明書は通常、全てのExtron electronic 200ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Extron electronicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Extron electronic 200の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははExtron electronic 200の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Extron electronic 200に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Extron electronic 200デバイスの基本機能を使うにあたってのヒント。 Extron electronic 200のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Extron electronic 200に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるExtron electronic 200のメーカー/サービスへの連絡先に関する情報。

Extron electronic 200についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもExtron electronic 200の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがExtron electronic 200で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。