2 E X TENDED RUN TIM E SERIES XRT Series of Bat tery Packs I. INTRODUCT ION............................................................... 2 Safety Cautions II. INSTALLA TION ................................................................ 5 Cautions ............................................................................ 5 Installation Placem ...
-
Minuteman UPS XRT Series - page 3
3 Thank y ou f or purchasing the Minutem an XRT ser ies of external Battery Pack s for your MINUTEMAN Uninterruptible Power Supply sy stem . It has been designed and m anufactured to pr ovide many y ear s of trouble- free s ervice. The batteries used in the XRT s eries are sealed, m aintenance-free, lead- acid batteries, with the electrolyte com pl ...
-
Minuteman UPS XRT Series - page 4
4 RECEIVING INSPECTIO N Upon receipt of the Battery Pack , check the outer packaging for any external dam age that may have been caused by the carrier. After rem oving y our Minutem an XRT Battery Pack f rom its carton, inspect the unit again for any damage that m ay have occ urred in shipping. Notify the carrier and plac e of purchase im mediately ...
-
Minuteman UPS XRT Series - page 5
5 INSTRUCT IONS IMPORTANTES CONCERNA NT LA SÉCURITÉ: CONSERVER CES INSTRUCT IONS. CETTE NOT ICE CONTIENT DES INSTRUCT IONS IMPORTANTES CONCERNA NT LA SÉCURITÉ. A T TENTION: UNE BA TT ERIE PEUT PRÉSENTER US RISQUE DE CHOC ÉLECTRIQUE, OU DE BRULURE PA R T RA NSFERT D'ENERGIE. SUIVRE LES PRÉCA UTIONS QUI S' IMPOSENT . CA UT ION: A VOI ...
-
Minuteman UPS XRT Series - page 6
6 CA UT IONS: It is recom mended that you turn the UPS off and disconnect it from the AC wall outlet prior to connecting or dis connecting the battery terminals. If battery packs MUST be changed while the UPS is supplying pow er to protected equipm ent, they can O NLY be c hanged w hile the AC line is supplying pow er . DO NOT attem pt to replace b ...
-
Minuteman UPS XRT Series - page 7
7 INSTALLA T ION PLACEMENT: Select the location of the battery pack (s) with care and use the f ollowing precautions; 1. Avoid locations near heating devices. 2. Avoid locations near water or ex cessive hum idity . 3. Do not expose the Battery Pack to dir ect sunlight. 4. Route power cords where they cannot be walked on or dam aged. The battery pac ...
-
Minuteman UPS XRT Series - page 8
8 A suggested layout for stack ing multiple battery packs should be determ ined by the technician perf orming your installation. Each installation is unique to the j ob site and should be reviewed and planned PRIOR to m oving this heavy equipm ent. Measuring the equipm ent and the installation site m ay be requir ed. Alw ays m ake sure your floor s ...
-
Minuteman UPS XRT Series - page 9
9 4. Loosen but do not rem ove the retainer screws on the r ear panel of the UPS, then drop the retainer brac ket down. This r etaining bracket is not present on all m odels. 5. Plug the cable connector into the XRT UPS rem ote battery pac k connector, ins uring the connectors m ate Red to Red and Black to Black . 6. Push the retaining brac ket &qu ...
-
Minuteman UPS XRT Series - page 10
10 installed all of the way into the receptacle. Upon succ essful connection, verif y that the brack et will not allow removal of the connector. For m ultiple battery pack installation, each battery pack is "dais y chained" in a sim ilar fashion, with the cable from the last battery pack connec ted to the previous pack . Remove the pr ote ...
-
Minuteman UPS XRT Series - page 11
11 4. In order to locate the ter minal block on the battery pack y ou will need to rem ove the top cover of the battery pack. Note: O n some m odels, the term inal block m ay be acc essed from the rear panel of the battery pack. Warning: When th e cover is removed, danger of shock exists from the batteries. Use extreme caut ion. 5. Connect the posi ...
-
Minuteman UPS XRT Series - page 12
12 7. Reinstall the cover plates on the back of the UPS if they were rem oved. 8. The unit is now ready for norm al startup procedur es as described in the UPS owner's m anual. Make sure all switches and breakers on all units installed are plac ed in the ON position. Failure to have all of the switches in the ON pos ition may render the UPS in ...
-
Minuteman UPS XRT Series - page 13
13 Note: On all MINUT EMA N Plug and Play configurations, the red connector is battery positive and the black connector is battery negative. 5. After all c onnections have been made and ver i fied to be correct, reinstall the cover on the battery pack if it was rem oved. Insure all cover s crews are installed. 6. Reinstall the cover plates on the b ...
-
Minuteman UPS XRT Series - page 14
14 If the Battery Pack requir es service: Before retur ning a defective unit to Minutem an, please follow the standard proc edures listed below. 1. Call y our dealer for assis tance. If y ou cannot reach y our dealer, or if the problem cannot be resolved, call or f ax Minuteman's T echnical Support departm ent at the following numbers : Voice ...
-
Minuteman UPS XRT Series - page 15
15 4. Include a letter with y our name, address , day tim e phone number, RMA #, a copy of y our or iginal sales receipt, and a brief description of the trouble. 5. Mark the RMA # on the outside of all packages . The factor y cannot accept any package without the RMA # m arked on the outside. 6. Return the Battery Pack by insured, prepaid carrier t ...
-
Minuteman UPS XRT Series - page 16
16 LIMIT ED PRODUCT WA RRANTY Para Systems, Inc . (Para Sy stem s) warrants this equipment, when properly applied and operated within specified conditions, agains t faulty mater ials, or workm anship for a period of two y ears f rom the date of original purchas e by the end user. For equipm ent sites within the United States and Canada, this warran ...
-